C-arm cone-beam CT (CBCT) often acquires data over a limited angular range. Image reconstruction from limited-angle data (i.e., data less than a short scan) becomes mathematically an ill-posed problem, and the inversion of the X-ray transform by use of conventional analytic formulas can introduce significant artifacts. In this work, using the adaptive steepest descent and projection-onto-convex-sets (ASD-POCS) algorithm, we investigate image reconstructions from limited-angle simulation cone-beam data and real patient data acquired with a C-arm system. The results show that the algorithm can reconstruct potentially useful images from data collected over limited angular range.
引用
收藏
页码:3977 / 3979
页数:3
相关论文
共 27 条
  • [1] Optimization-based image reconstruction with artifact reduction in C-arm CBCT
    Xia, Dan
    Langan, David A.
    Solomon, Stephen B.
    Zhang, Zheng
    Chen, Buxin
    Lai, Hao
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20) : 7300 - 7333
  • [2] WAVELET TIGHT FRAME AND PRIOR IMAGE-BASED IMAGE RECONSTRUCTION FROM LIMITED-ANGLE PROJECTION DATA
    Wang, Chengxiang
    Zeng, Li
    Guo, Yumeng
    Zhang, Lingli
    INVERSE PROBLEMS AND IMAGING, 2017, 11 (06) : 917 - 948
  • [3] An adaptive iteration reconstruction method for limited-angle CT image reconstruction
    Wang, Chengxiang
    Zeng, Li
    Zhang, Lingli
    Guo, Yumeng
    Yu, Wei
    JOURNAL OF INVERSE AND ILL-POSED PROBLEMS, 2018, 26 (06): : 771 - 787
  • [4] A preconditioned landweber iteration scheme for the limited-angle image reconstruction
    Shi, Lei
    Qu, Gangrong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (06) : 1045 - 1063
  • [5] Low contrast 3D-reconstruction from C-arm data
    Zellerhoff, M
    Scholz, B
    Rührnschopf, EP
    Brunner, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 646 - 655
  • [6] Multiobjective optimization guided by image quality index for limited-angle CT image reconstruction
    He, Yu
    Wang, Chengxiang
    Yu, Wei
    Wang, Jiaxi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (05) : 1209 - 1237
  • [7] Accurate image reconstruction using real C-arm data from a Circle-plus-arc trajectory
    Hoppe, Stefan
    Hornegger, Joachim
    Dennerlein, Frank
    Lauritsch, Guenter
    Noo, Frederic
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 73 - 86
  • [8] Anisotropic structure property based image reconstruction method for limited-angle computed tomography
    Gong, Changcheng
    Zeng, Li
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (06) : 1079 - 1102
  • [9] Sparsity-constrained three-dimensional image reconstruction for C-arm angiography
    Rashed, Essam A.
    al-Shatouri, Mohammad
    Kudo, Hiroyuki
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 62 : 141 - 153
  • [10] Iterative image reconstruction for limited-angle inverse helical cone-beam computed tomography
    Yu, Wei
    Zeng, Li
    SCANNING, 2016, 38 (01) : 4 - 13