Measurements of in vivo intra-articular gentamicin levels from antibiotic loaded articulating spacers in revision total knee replacement

被引:30
作者
Mutimer, J. [1 ]
Gillespie, G. [1 ]
Lovering, A. M. [1 ]
Porteous, A. J. [1 ]
机构
[1] Southmead Hosp, Bristol, Avon, England
关键词
Knee; Arthroplasty; Infection; Antibiotic; Therapy; CEMENT;
D O I
10.1016/j.knee.2008.07.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Previous in vitro studies have found high levels of antibiotic release in the days immediately following implantation of antibiotic loaded articulating spacers. However there are relatively few data describing the elution profile beyond this immediate period. This study was designed to measure if gentamicin levels continue to be clinically therapeutic after an extended period following in vivo implantation. Twelve patients received a gentamicin loaded articulating spacer between a 1st and 2nd stage revision total knee arthroplasty. At the 2nd stage procedure synovial fluid and blood samples were collected and assayed for the presence of gentamicin. The second stage revision occurred at a median of 99 days following spacer insertion. The median intra-articular gentamicin levels were 0.46 mg/L (0.24 to 2.36 mg/L) which would be considered therapeutic. There were no cases of reinfection. In this study, preformed articulating spacers containing gentamicin provided therapeutic concentrations in the synovial fluid surrounding the joint throughout the period of implantation. These data confirm the observations from in vitro studies, where a prolonged elution profile was observed for such spacers. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 41
页数:3
相关论文
共 12 条
[1]   THE INFECTED KNEE ARTHROPLASTY - A 6-YEAR FOLLOW-UP OF 357 CASES [J].
BENGTSON, S ;
KNUTSON, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (04) :301-311
[2]  
*BMJ PUBL GROUP LT, 2006, BRIT NAT FORM, V52, P287
[3]  
Buchholz H.W., 1984, Clin. Orthop, V190, P96
[4]  
Castelli C, 2001, BONE CEMENT CEMENTED, P181
[5]  
COHEN JC, 1998, J ARTHROPLASTY, V3, P369
[6]  
GILL GS, 1991, CLIN ORTHOP RELAT R, V273, P66
[7]  
Hanssen A D, 1999, Instr Course Lect, V48, P111
[8]   The in vitro elution of gentamicin sulfate from a commercially available gentamicin-loaded acrylic bone cement, VersaBond™ AB [J].
Lewis, G ;
Janna, S .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 71B (01) :77-83
[9]   ANTIBIOTIC-IMPREGNATED ACRYLIC BONE CEMENT [J].
MARKS, KE ;
NELSON, CL ;
LAUTENSCHLAGER, EP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03) :358-364
[10]   Gentamicin release from old cement during revision hip arthroplasty [J].
Powles, JW ;
Spencer, RF ;
Lovering, AM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :607-610