Evaluation of stainless steel pipe performance as a ground heat exchanger in ground-source heat-pump system

被引:16
作者
Yoon, Seok [1 ,2 ]
Lee, Seung-Rae [2 ]
Kim, Min-Jun [2 ]
Kim, Woo-Jin [2 ]
Kim, Geon-Young [1 ]
Kim, Kyungsu [1 ]
机构
[1] KAERI, Div Radioact Waste Disposal Res, Daejeon 34057, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, 291 Gwahakro, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
Stainless steel pipe; Ground heat exchanger; Thermal response test; Heat-exchange rate; IN-SITU DETERMINATION; THERMAL PERFORMANCE; OPERATION MODE; RESISTANCE; TUBE; FLOW;
D O I
10.1016/j.energy.2016.07.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a numerical and experimental study of the evaluation of stainless steel (STS) pipe performance as a ground heat exchanger (GHE). U-type GHEs of circular polybutylene (PB) and annular STS were installed in a steel box (5 m x 1 m x 1 m), and indoor thermal response tests (TRTs) were conducted for 30 h to evaluate the heat-exchange rates. The U-type GHEs of PB, annular STS, and indoor TRT conditions were numerically modeled using a three-dimensional finite-element method. The average pipe diameter for the annular STS pipe was determined by the finite-element method. The exchange rate of the annular STS pipe was approximately 10% higher than that of the circular PB pipe, and the temperature distributions measured in the TRT and calculated by the numerical analysis exhibited reasonable agreement. In addition, the borehole thermal resistance and heat-exchange rate under the assumption that the annular STS pipe would be applied in an actual vertical heat exchanger system were calculated. It is expected that the borehole thermal resistance would be decreased by 25% and that the heat-exchange rate would be increased by 15% with annular STS pipe in comparison with PB pipe. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 53 条
[11]  
Carslaw H. S., 1947, Conduction of heat in solids
[12]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[13]  
Comsol Inc, 2012, COMS MULT US MAN VER
[14]   Heat transfer analysis of pile geothermal heat exchangers with spiral coils [J].
Cui, Ping ;
Li, Xin ;
Man, Yi ;
Fang, Zhaohong .
APPLIED ENERGY, 2011, 88 (11) :4113-4119
[15]  
D'Arpa S, 2015, ENERGY EFFIC
[16]   Ground heat exchangers - A review of systems, models and applications [J].
Florides, Georgios ;
Kalogirou, Soteris .
RENEWABLE ENERGY, 2007, 32 (15) :2461-2478
[17]   First in situ determination of the thermal performance of a U-pipe borehole heat exchanger, in Cyprus [J].
Florides, Georglos ;
Kalogirou, Soteris .
APPLIED THERMAL ENGINEERING, 2008, 28 (2-3) :157-163
[18]   Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study [J].
Gao, Jun ;
Zhang, Xu ;
Liu, Jun ;
Li, Kui Shan ;
Yang, Jie .
APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) :2295-2304
[19]   A new performance evaluation algorithm for horizontal GCHPs (ground coupled heat pump systems) that considers rainfall infiltration [J].
Go, Gyu-Hyun ;
Lee, Seung-Rae ;
Nikhil, N., V ;
Yoon, Seok .
ENERGY, 2015, 83 :766-777
[20]   Field performance of an energy pile system for space heating [J].
Hamada, Yasuhiro ;
Saitoh, Hisashi ;
Nakamura, Makoto ;
Kubota, Hideki ;
Ochifuji, Kiyoshi .
ENERGY AND BUILDINGS, 2007, 39 (05) :517-524