Sensitive and Rapid Flow Injection Amperometric Hydrazine Sensor using an Electrodeposited Gold Nanoparticle Graphite Pencil Electrode

被引:18
作者
Teoman, Ismail [1 ]
Karakaya, Serkan [1 ]
Dilgin, Yusuf [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Fac Sci & Art, Dept Chem, TR-17020 Canakkale, Turkey
关键词
Amperometric sensor; electrocatalytic oxidation of hydrazine; flow injection analysis; Au nanoparticles; graphite pencil electrode; ENHANCED ELECTROCATALYTIC ACTIVITY; CORE-SHELL NANOPARTICLES; GLASSY-CARBON ELECTRODE; TRACE HYDRAZINE; OXIDATION; PERFORMANCE; GRAPHENE; WATER; FILM; DERIVATIZATION;
D O I
10.1080/00032719.2019.1591429
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gold (Au) nanoparticle-modified graphite pencil electrode was prepared by an electrodeposition procedure for the sensitive and rapid flow injection amperometric determination of hydrazine (N2H4). The electrodeposited Au nanoparticles on the pretreated graphite pencil electrode surface were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction spectroscopy, and electrochemical impedance spectroscopy. Cyclic voltammograms showed that the Au nanoparticle-modified pretreated graphite pencil electrode exhibits excellent electrocatalytic activity toward oxidation of hydrazine because the highly irreversibly and broadly observed oxidation peak at +600 mV at the pretreated graphite pencil electrode shifted to -167 mV at the Au nanoparticle pretreated graphite pencil electrode; in addition, a significant enhancement in the oxidation peak current was obtained. Thus, the flow-injection (FI) amperometric hydrazine sensor was constructed based on its electrocatalytic oxidation at the Au nanoparticle-modified pretreated graphite pencil electrode. The Au nanoparticle-modified pretreated graphite pencil electrode exhibits a linear calibration curve between the flow injection amperometric current and hydrazine concentration within the concentration range from 0.01 to 100 mu M with a detection limit of 0.002 mu M. The flow injection amperometric sensor has been successfully used for the determination of N2H4 in water samples with good accuracy and precision.
引用
收藏
页码:2041 / 2056
页数:16
相关论文
共 50 条
  • [21] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Md. Abdul Aziz
    Abdel-Nasser Kawde
    Microchimica Acta, 2013, 180 : 837 - 843
  • [22] Flow injection analysis of ethambutol in synthetic urine using a graphite-polyurethane composite electrode as an amperometric detector
    Perantoni, Camila B.
    de Azevedo, Alessandra B. R.
    Vaz, Fernando A. S.
    de Oliveira, Marcone A. L.
    Matos, Renato C.
    Lowinsohn, Denise
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (10): : 1668 - 1673
  • [23] Amperometric sensor for dopamine based on surface-graphenization pencil graphite electrode prepared by in-situ electrochemical delamination
    Fan, Xuexue
    Xu, Yanan
    Sheng, Tiandu
    Zhao, Dongqing
    Yuan, Haikuan
    Liu, Fengjiao
    Liu, Xijian
    Zhu, Xueyan
    Zhang, Lijuan
    Lu, Jie
    MICROCHIMICA ACTA, 2019, 186 (05)
  • [24] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [25] Sensitive Electrochemical Determination of Bisphenol a Using a Disposable, Electrodeposited Antimony-Graphene Nanocomposite Pencil Graphite Electrode (PGE) and Differential Pulse Voltammetry (DPV)
    Ghaffari, Nastaran
    Pokpas, Keagan
    Iwuoha, Emmanuel
    Jahed, Nazeem
    ANALYTICAL LETTERS, 2024, 57 (06) : 1008 - 1025
  • [26] Simple and sensitive detection of 4-nitrophenol in real water samples using gold nanoparticles modified pretreated graphite pencil electrode
    Rana, Azeem
    Kawde, Abdel-Nasser
    Ibrahim, Mohamed
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 820 : 24 - 31
  • [27] A New Redox Mediator (Cupric-Neocuproine Complex)-Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H2O2: A Flow Injection Amperometric Sensor
    Emir, Gamze
    Dilgin, Yusuf
    Apak, Resat
    CHEMELECTROCHEM, 2020, 7 (03) : 649 - 658
  • [28] Determination of Epinephrine using a Novel Sensitive Electrochemiluminescence Sensor based on ZnO Nanoparticles Modified Pencil Graphite Electrode
    Zheng, Ruijuan
    Zhao, Chenhao
    Zhong, Jianhai
    Qiu, Zehai
    Hu, Zhibiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 9380 - 9390
  • [29] Highly Sensitive Amperometric Hydrazine Sensor Developed from Gold Nanoparticles Electrodeposited on Glassy Carbon Electrode Modified with Graphene Oxide and Poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) Composite
    Rahman, Hemas Arif
    Putra, Budi Riza
    Rafi, Mohamad
    Heryanto, Rudi
    Takai-Yamashita, Chika
    Ohya, Yutaka
    Wahyuni, Wulan Tri
    SENSORS AND MATERIALS, 2023, 35 (12) : 4177 - 4202
  • [30] A cysteine sensor based on a gold nanoparticle-iron phthalocyanine modified graphite paste electrode
    Abbas, Mohammed Nooredeen
    Saeed, Ayman Ali
    Singh, Baljit
    Radowan, Abdellatef A.
    Dempsey, Eithne
    ANALYTICAL METHODS, 2015, 7 (06) : 2529 - 2536