Preliminary Application of High-Definition CT Gemstone Spectral Imaging in Hand and Foot Tendons

被引:15
作者
Deng, Kai [1 ]
Zhang, Cheng-Qi [1 ]
Li, Wei [1 ]
Wang, Jun-Jun [2 ]
Wang, Xin-Yi [1 ]
Pang, Tao [1 ]
Wang, Guang-Li [1 ]
Liu, Cheng [3 ]
机构
[1] Shandong Univ, Qianfoshan Hosp, Dept Med Imaging, Jinan 250014, Peoples R China
[2] Shandong Univ, Coll Med, Jinan 250012, Peoples R China
[3] Shandong Med Imaging Res Inst, Jinan 250021, Peoples R China
关键词
Dual energy CT; Spectral imaging; Magnetic resonance imaging; Tendon; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; MRI;
D O I
10.3348/kjr.2012.13.6.743
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess the feasibility of visualizing hand and foot tendon anatomy and disorders by Gemstone Spectral Imaging (GSI) high-definition CT (HDCT). Materials and Methods: Thirty-five patients who suffered from hand or foot pain were scanned with GSI mode HDCT and MRI. Spectrum analysis was used to select the monochromatic images that provide the optimal contrast-to-noise ratio (CNR) for tendons. The image quality at the best selected monochromatic level and the conventional polychromatic images were compared. Tendon anatomy and disease were also analyzed at GSI and MRI. Results: The monochromatic images at about 65 keV (mean 65.1 +/- 2.98) provided the optimal CNR for hand and foot tendons. The image quality at the optimal selected monochromatic level was superior to conventional polychromatic images (p = 0.005, p < 0.05). GSI was useful in visualizing hand and foot tendon anatomy and disorders. There were no statistical differences between GSI and MRI with regard to tendon thickening (chi(2) = 0, p > 0.05), compression (chi(2) = 0.5, p > 0.05), absence (chi(2) = 0, p > 0.05) and rupture (chi(2) = 0, p > 0.05). GSI was significantly less sensitive than MRI in displaying tendon adhesion (chi(2) = 4.17, p < 0.05), degeneration (chi(2) = 4.17, p < 0.05), and tendinous sheath disease (chi(2) = 10.08, p < 0.05). Conclusion: GSI with monochromatic images at 65 keV displays clearly the most hand and foot tendon anatomy and disorders with image quality improved, as compared with conventional polychromatic images. It may be used solely or combined with MRI in clinical work, depending on individual patient disease condition.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 17 条
[1]  
Bencardino J.T., 2004, Magn Reson Imaging Clin N Am, V12, pvii
[2]  
Bencardino Jenny T, 2004, Magn Reson Imaging Clin N Am, V12, P333, DOI 10.1016/j.mric.2004.02.010
[3]   MR imaging of ligament and tendon injuries of the fingers [J].
Clavero, JA ;
Alomar, X ;
Monill, JM ;
Esplugas, M ;
Golanó, P ;
Mendoza, M ;
Salvador, A .
RADIOGRAPHICS, 2002, 22 (02) :237-256
[4]   Informatics in radiology (infoRAD) -: Introduction to the language of three-dimensional imaging with multidetector CT [J].
Dalrymple, NC ;
Prasad, SR ;
Freckleton, MW ;
Chintapalli, KN .
RADIOGRAPHICS, 2005, 25 (05) :1409-1428
[5]   Initial experience with visualizing hand and foot tendons by dual-energy computed tomography [J].
Deng, Kai ;
Sun, Cong ;
Liu, Cheng ;
Ma, Rui .
CLINICAL IMAGING, 2009, 33 (05) :384-389
[6]   Collateral Ventilation to Congenital Hyperlucent Lung Lesions Assessed on Xenon-Enhanced Dynamic Dual-Energy CT: an Initial Experience [J].
Goo, Hyun Woo ;
Yang, Dong Hyun ;
Kim, Namkug ;
Park, Seung Il ;
Kim, Dong Kwan ;
Kim, Ellen Ai-Rhan .
KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (01) :25-33
[7]  
Hur S, 2012, KOREAN J RADIOL, V13, P152, DOI [10.3348/kjr.2012.13.2.152, 10.7874/kja.2012.16.3.152]
[8]   Musculoskeletal ultrasound and MRI: Which do I choose? [J].
Jacobson, JA .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2005, 9 (02) :135-149
[9]   High-Definition CT Gemstone Spectral Imaging of the Brain: Initial Results of Selecting Optimal Monochromatic Image for Beam-Hardening Artifacts and Image Noise Reduction [J].
Lin, Xiao Zhu ;
Miao, Fei ;
Li, Jian Ying ;
Dong, Hai Peng ;
Shen, Yun ;
Chen, Ke Min .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (02) :294-297
[10]   Peroneal tendon subluxation and dislocation: Detection on volume-rendered images - Initial experience [J].
Ohashi, Kenjirou ;
Restrepo, Jose M. ;
El-Khoury, Georges Y. ;
Berbaum, Kevin S. .
RADIOLOGY, 2007, 242 (01) :252-257