Single passive leg movement-induced hyperemia: a simple vascular function assessment without a chronotropic response

被引:30
作者
Venturelli, Massimo [1 ,2 ]
Layec, Gwenael [1 ]
Trinity, Joel [1 ,3 ]
Hart, Corey R. [4 ]
Broxterman, Ryan M. [4 ]
Richardson, Russell S. [1 ,3 ,4 ]
机构
[1] Univ Utah, Dept Internal Med, Div Geriatr, Salt Lake City, UT 84112 USA
[2] Univ Verona, Dept Neurosci Biomed & Movement Sci, Via Casorati 43, I-37127 Verona, Italy
[3] George E Whalen Vet Affairs Med Ctr, Geriatr Res Educ & Clin Ctr, Salt Lake City, UT USA
[4] Univ Utah, Dept Exercise & Sport Sci, Salt Lake City, UT USA
基金
美国国家卫生研究院;
关键词
flow-mediated dilation; endothelial function; cardiovascular disease assessment; FLOW-MEDIATED DILATION; ENDOTHELIAL FUNCTION; NITRIC-OXIDE; SKELETAL-MUSCLE; LIMB MOVEMENT; GROUP-III; DETERMINANTS; DYSFUNCTION; AFFERENTS; PRESSURE;
D O I
10.1152/japplphysiol.00806.2016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Passive leg movement (PLM)-induced hyperemia is a novel approach to assess vascular function, with a potential clinical role. However, in some instances, the varying chronotropic response induced by PLM has been proposed to be a potentially confounding factor. Therefore, we simplified and modified the PLM model to require just a single PLM (sPLM), an approach that may evoke a peripheral hemodynamic response, allowing a vascular function assessment, but at the same time minimizing central re-sponses. To both characterize and assess the utility of sPLM, in 12 healthy subjects, we measured heart rate (HR), stroke volume, cardiac output (CO), mean arterial pressure (MAP), leg blood flow (LBF), and calculated leg vascular conductance (LVC) during both standard PLM, consisting of passive knee flexion and extension performed at 1 Hz for 60 s, and sPLM, consisting of only a single passive knee flexion and extension over 1 s. During PLM, MAP transiently decreased (5 +/- 1 mmHg), whereas both HR and CO increased from baseline (6.0 +/- 1.1 beats/min, and 0.8 +/- 0.01 l/min, respectively). Following sPLM, MAP fell similarly (5 +/- 2 mmHg; P = 0.8), but neither HR nor CO responses were identifiable. The peak LBF and LVC response was similar for PLM (993 (+/-) 189 ml/min; 11.9 +/- 1.5 ml.min(-1).mmHg(-1), respectively) and sPLM (878 +/- 119 ml/min; 10.9 +/- 1.6 ml.min(-1).mmHg(-1), respectively). Thus sPLM represents a variant of the PLM approach to assess vascular function that is more easily performed and evokes a peripheral stimulus that induces a significant hyperemia, but does not generate a potentially confounding, chronotropic response, which may make sPLM more useful clinically. NEW & NOTEWORTHY Using the single passive leg movement (PLM) technique, a variant of the vascular function assessment PLM, we have identified a novel peripheral vascular assessment method that is more easily performed than PLM, which, by not evoking potentially confounding central hemodynamic responses, may be more useful clinically.
引用
收藏
页码:28 / 37
页数:10
相关论文
共 39 条
  • [1] Effect of arterial occlusion on responses of group III and IV afferents to dynamic exercise
    Adreani, CM
    Kaufman, MP
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (06) : 1827 - 1833
  • [2] Responses of group III and IV muscle afferents to dynamic exercise
    Adreani, CM
    Hill, JM
    Kaufman, MP
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (06) : 1811 - 1817
  • [3] CLOSE RELATION OF ENDOTHELIAL FUNCTION IN THE HUMAN CORONARY AND PERIPHERAL CIRCULATIONS
    ANDERSON, TJ
    UEHATA, A
    GERHARD, MD
    MEREDITH, IT
    KNAB, S
    DELAGRANGE, D
    LIEBERMAN, EH
    GANZ, P
    CREAGER, MA
    YEUNG, AC
    SELWYN, AP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (05) : 1235 - 1241
  • [4] Endothelial dysfunction assessed by brachial artery ultrasound in severe sepsis and septic shock
    Becker, Leandro
    Prado, Karen
    Foppa, Murilo
    Martinelli, Nidiane
    Aguiar, Cynthia
    Furian, Thiago
    Clausell, Nadine
    Rohde, Luis Eduardo
    [J]. JOURNAL OF CRITICAL CARE, 2012, 27 (03) : 316.e9 - 316.e14
  • [5] Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger
    Bogert, LWJ
    van Lieshout, JJ
    [J]. EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) : 437 - 446
  • [6] Current and future initiatives for vascular health management in clinical practice
    Cameron, James D.
    Asmar, Roland
    Struijker-Boudier, Harry
    Shirai, Kohji
    Sirenko, Yuriy
    Kotovskaya, Yulia
    Topouchian, Jirar
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2013, 9 : 255 - 264
  • [7] NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS
    CELERMAJER, DS
    SORENSEN, KE
    GOOCH, VM
    SPIEGELHALTER, DJ
    MILLER, OI
    SULLIVAN, ID
    LLOYD, JK
    DEANFIELD, JE
    [J]. LANCET, 1992, 340 (8828) : 1111 - 1115
  • [8] Determinants of endothelial function in patients with COPD
    Clarenbach, Christian F.
    Senn, Oliver
    Sievi, Noriane A.
    Camen, Giovanni
    van Gestel, Arnoldus J. R.
    Rossi, Valentina A.
    Puhan, Milo A.
    Thurnheer, Robert
    Russi, Erich W.
    Kohler, Malcolm
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2013, 42 (05) : 1194 - 1204
  • [9] CHEMICAL ENERGETICS OF SLOW-TWITCH AND FAST-TWITCH MUSCLES OF THE MOUSE
    CROW, MT
    KUSHMERICK, MJ
    [J]. JOURNAL OF GENERAL PHYSIOLOGY, 1982, 79 (01) : 147 - 166
  • [10] Endothelial function and dysfunction - Testing and clinical relevance
    Deanfield, John E.
    Halcox, Julian P.
    Rabelink, Ton J.
    [J]. CIRCULATION, 2007, 115 (10) : 1285 - 1295