Total Endovascular Repair of the Aortic Arch: Initial Experience in the Netherlands

被引:40
|
作者
van der Weijde, Emma [1 ]
Heijmen, Robin H. [1 ,2 ]
van Schaik, Paul M. [3 ]
Hazenberg, Constantijn E. V. B. [4 ]
van Herwaarden, Joost A. [4 ]
机构
[1] St Antonius Hosp, Dept Cardiothorac Surg, Postbus 2500, NL-3430 EM Nieuwegein, Netherlands
[2] Med Ctr Amsterdam, Dept Cardiothorac Surg, Amsterdam, Netherlands
[3] Univ Med Ctr Groningen, Dept Vasc Surg & Endovasc, Groningen, Netherlands
[4] Univ Med Ctr Utrecht, Dept Vasc Surg, Utrecht, Netherlands
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 06期
关键词
SINGLE-CENTER EXPERIENCE; LEFT SUBCLAVIAN ARTERY; PERIOPERATIVE STROKE; FEASIBILITY;
D O I
10.1016/j.athoracsur.2019.09.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We report procedural and early results in the Netherlands of the Relay Branch device (Terumo Aortic, Sunrise, FL) for total endovascular repair of the aortic arch. Methods. Between 2014 and 2018, all consecutive patients who received the Aortic Relay double-branched stent graft in the Netherlands were included in a multicenter, retrospective registry. Results. The Relay Branch device was used in 11 patients to treat saccular (n = 4), fusiform (n = 5), or false aneurysms (n = 2) in the aortic arch. Patients were deemed unfit or extreme high-risk for open (redo) surgery. The brachiocephalic trunk and left common carotid artery were branched using a retrograde approach in all cases. Additional surgical left subclavian artery revascularization was performed in 8 patients. The main device and the branches were successfully introduced, positioned, and deployed with complete exclusion of the aortic pathology in all patients (100% technical success). There was no retrograde type A dissection or conversion to open surgery. Two procedure-related deaths occurred, both caused by perioperative or postoperative strokes. There were 2 minor strokes with full recovery. One patient recovered from transient paraplegia after spinal fluid drainage. No permanent paraplegia was observed. Follow-up imaging showed persistent adequate exclusion of aortic arch pathology. Mean follow-up was 17 months (range, 3-42 months). Conclusions. Total endovascular aortic arch repair using the Relay Branch device is technically feasible and effective in excluding aortic arch pathology. The observed stroke rate in the initial experience, however, was considerable. Although appealing, this new less-invasive technique should be carefully introduced and its progress thoroughly evaluated. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:1858 / 1863
页数:6
相关论文
共 50 条
  • [31] Total aortic endovascular repair
    Hongku, Kiattisak
    Dias, Nuno V.
    Sonesson, Bjorn
    Resch, Timothy A.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (06): : 784 - 805
  • [32] Meta-analysis and meta-regression of the total endovascular aortic repair in aortic arch
    Ahmad, Wael
    Wegner, Moritz
    Dorweiler, Bernhard
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2023, 52 (03) : 175 - 185
  • [33] Endovascular treatment of the aortic arch with the NEXUS™ prosthesis: initial experience of a single center
    Acuna, Beatriz
    Legarra, Juan J.
    Vidal, Jorge
    Encisa, Jose M.
    Pinon, Miguel A.
    CIRUGIA CARDIOVASCULAR, 2022, 29 (02): : 72 - 78
  • [34] The hybrid total arch repair: Brachiocephalic bypass and concomitant endovascular aortic arch stent graft placement
    Szeto, Wilson Y.
    Bavaria, Joseph E.
    Bowen, Frank W.
    Woo, Edward Y.
    Fairman, Ronald M.
    Pochettino, Alberto
    JOURNAL OF CARDIAC SURGERY, 2007, 22 (02) : 97 - 102
  • [35] Aortic arch debranching and thoracic endovascular repair
    De Rango, Paola
    Cao, Piergiorgio
    Ferrer, Ciro
    Simonte, Gioele
    Coscarella, Carlo
    Cieri, Enrico
    Pogany, Gabriele
    Verzini, Fabio
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (01) : 107 - 114
  • [36] The 10 Commandments of Aortic Arch Endovascular Repair
    Waterford, Stephen D.
    Ghoreishi, Mehrdad
    Toursavadkohi, Shahab
    Taylor, Bradley S.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2022, 17 (04) : 266 - 272
  • [37] Endovascular repair for thoracic aortic arch aneurysms
    Caronno, R.
    Piffaretti, G.
    Tozzi, M.
    Lomazzi, C.
    Cuffari, S.
    Sala, A.
    Castelli, P.
    INTERNATIONAL ANGIOLOGY, 2006, 25 (03) : 249 - 255
  • [38] A Challenging Proximal Aortic Arch Endovascular Repair
    Girsowicz, Elie
    Steinmetz, Oren
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 61 (02) : 190 - 190
  • [39] Ten Years of Endovascular Aortic Arch Repair
    Chiesa, Roberto
    Mellissano, Germano
    Tshomba, Yamume
    Civilini, Efrem
    Marone, Enrico Maria
    Bertoglio, Luca
    Calliari, Fabio Massimo
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (01) : 1 - 11
  • [40] Innovation and instrumentation: Endovascular repair of the aortic arch
    Coselli, Joseph S.
    Green, Susan Y.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04): : 1717 - 1718