Simultaneous Determination of Five Polyether Ionophores Using Liquid Chromatography with One-step Fluorescent Derivatization

被引:2
作者
Inoue, Koichi [1 ]
Miura, Yukiko [1 ]
Suzuki, Misato [1 ]
Kishikawa, Naoya [2 ]
Hino, Tomoaki [1 ]
Kuroda, Naotaka [2 ]
Oka, Hisao [1 ]
机构
[1] Kinjo Gakuin Univ, Sch Pharm, Dept Phys & Analyt Chem, Moriyama Ku, Nagoya, Aichi 4638521, Japan
[2] Nagasaki Univ, Course Pharmaceut Sci, Grad Sch Biomed Sci, Nagasaki 8528521, Japan
关键词
TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; BISPHENOL-A; ANTIBIOTICS; WATER; EGGS; COCCIDIOSTATS; REAGENT;
D O I
10.2116/analsci.28.175
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a selective method for simultaneous determination of five polyether ionophores such as salinomycin (SAL), monensin (MON), narasin (NAR), semduramicin (SEM) and lasalocid (LAS) in aquatic samples using a liquid chromatography with one-step fluorescent derivatization of 2-(4-hydrazinocarbonyl-phenyl) 4,5-diphenylimidazole (HCPI) and 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride hydrochloride (DIB-Cl). Fluorescent one-step derivatization for SAL, MON, NAR and SEM using HCPI and for LAS using DIB-Cl was monitored by an LC/fluorescence detector (E-x, 340 nm; E-m 465 nm). Chromatographic separation was performed on a TSK-GEL ODS-120T (4.6 x 150 mm, 3 mu m) column using a mobile phase of 0.1% formic acid in acetonitrile and 0.5 mM ammonium formate in water (70/30, v/v). The limits of detections were 0.01 mu g/mL (50 pg) for LAS, 0.05 mu g/mL (250 pg) for SAL, NAR and SEM, and 0.1 mu g/mL (500 pg) for MON, respectively. The recoveries for water samples were indicated to be the range of 79.6 +/- 6.4 - 99.0 +/- 4.4% with associated precision values (between-day for 3 days) for repeatability. Based on solid-phase extraction, the limit of quantitation values indicated 0.1 ng/mL for SAL, MON, NAR and SEM, and 0.01 ng/mL for LAS in water samples.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [1] Simultaneous determination of polyether ionophores, macrolides and lincosamides in hen eggs by liquid chromatography-electrospray ionization tandem mass spectrometry using a simple solvent extraction
    Spisso, Bernardete Ferraz
    Ferreira, Rosana Gomes
    Pereira, Mararlene Ulberg
    Monteiro, Mychelle Alves
    Cruz, Tatiana Avila
    da Costa, Rafaela Pinto
    Belem Lima, Adelia Mara
    da Nobrega, Armi Wanderley
    [J]. ANALYTICA CHIMICA ACTA, 2010, 682 (1-2) : 82 - 92
  • [2] Rapid Method for the Simultaneous Determination of Six Ionophores in Feed by Liquid Chromatography/Mass Spectrometry
    Vudathala, Daljit
    Murphy, Lisa
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (04) : 1016 - 1022
  • [3] One-Step Derivatization and Preconcentration Microextraction Technique for Determination of Bisphenol A in Beverage Samples by Gas Chromatography-Mass Spectrometry
    Fontana, Ariel R.
    de Toro, Monica Munoz
    Altamirano, Jorgelina C.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (08) : 3559 - 3565
  • [4] Simultaneous Determination of Polyether Antibiotics and Macrolide Anthelmintics in Livestock Products by Liquid Chromatography/Tandem Mass Spectrometry
    Yamaguchi, Mizuka
    Kakimoto, Kensaku
    Yamaguchi, Takahiro
    Obana, Hirotaka
    [J]. FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (05): : 281 - 286
  • [5] HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY DETERMINATION OF ANILINES WITH FLUORESCENT DETECTION AND PRE-COLUMN DERIVATIZATION
    Al-Kindy, Salma M. Z.
    Al-Kalbani, Azza
    Al-Harasi, Ahmed F.
    Suliman, FakhrEldin O.
    Al-Lawati, Haider J.
    Al-Hamadi, Abdalla
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (01) : 48 - 59
  • [6] Simultaneous determination of eight estrogens and their metabolites in serum using liquid chromatography with electrochemical detection
    Piwowarska, Jadwiga
    Radowicki, Stanislaw
    Pachecka, Jan
    [J]. TALANTA, 2010, 81 (1-2) : 275 - 280
  • [7] Determination of flavor enhancers in milk powder by one-step sample preparation and two-dimensional liquid chromatography
    Ma, Jing
    Zhang, Bing
    Wang, Yunan
    Hou, Xiaofang
    He, Langchong
    [J]. JOURNAL OF SEPARATION SCIENCE, 2014, 37 (08) : 920 - 926
  • [8] Determination of alkylphenols in water samples using liquid chromatography-tandem mass spectrometry after pre-column derivatization with dansyl chloride
    Pernica, Marek
    Poloucka, Petra
    Seifertova, Marta
    Simek, Zdenek
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1417 : 49 - 56
  • [9] Simultaneous determination of sulfonamides and metabolites in manure samples by one-step ultrasound/microwave-assisted solid-liquid-solid dispersive extraction and liquid chromatography-mass spectrometry
    Wu, Hui-zhen
    Qian, Ming-rong
    Wang, Jian-mei
    Zhang, Hu
    Ma, Jun-wei
    Li, Zu-guang
    Lee, Maw-rong
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (13) : 3545 - 3554
  • [10] Simultaneous determination of five types of 40 antibiotics in surface water using high performance liquid chromatography-tandem mass spectrometry
    Feng Mengjuan
    Yang Zhengbiao
    Zhang Qin
    Song Ninghui
    Liu Yanhua
    Guo Ruixin
    Chen Jianqiu
    Zhang Shenghu
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (05) : 525 - 532