Renal cyst pseudoenhancement: Beam-hardening effects on CT numbers

被引:149
作者
Maki, DD
Birnbaum, BA
Chakraborty, DP
Jacobs, JE
Carvalho, BM
Herman, GT
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Hosp Univ Penn, Dept Comp & Informat Sci, Philadelphia, PA 19104 USA
关键词
kidney; CT; cysts;
D O I
10.1148/radiology.213.2.r99nv33468
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if simple renal cysts may be accurately characterized with helical computed tomography (CT) during peak levels of renal enhancement. MATERIALS AND METHODS: Water-filled "cysts" were suspended in varying concentrations of iodine solution, meant to simulate varying levels of renal enhancement, within an abdominal phantom. Volume-averaging effects were minimized by scanning cylindric 5-30-mm cysts with a helical technique (collimation, 5 mm; pitch, 1:1). Axial and helical techniques were then compared, and volume-averaging effects were evaluated by scanning 10- and 20-mm round cysts with 3-, 5-, and 7-mm collimation at background attenuation levels of 100 and 200 HU. RESULTS: Cylindric cyst attenuation increased consistently with increasing background attenuation. As background attenuation increased by 90 HU, attenuation increased by 11-17 HU in small (5- or 10-mm) cysts, and by 7-9 HU in large (15-30-mm) cysts. As background attenuation increased by 180 HU, attenuation increased by 18-28 HU in small cysts and by 10-15 HU in large cysts. Spherical cyst attenuation differences were maximized when smaller cysts were imaged with larger collimation, which is when volume-averaging effects became apparent. Axial and helical CT numbers did not differ substantially. Computer simulation studies showed that the observed effect could not be explained by beam hardening alone. CONCLUSION: Pseudoenhancement of renal cysts may occur if helical CT is performed during peak renal enhancement. CT algorithm modification may be necessary to correct for this effect, which is likely related to an inadequate algorithmic correction for beam hardening.
引用
收藏
页码:468 / 472
页数:5
相关论文
共 10 条
[1]   Assessment of a bolus-traching technique in helical renal CT to optimize nephrographic phase imaging [J].
Birnbaum, BA ;
Jacobs, JE ;
Langlotz, CP ;
Ramchandani, P .
RADIOLOGY, 1999, 211 (01) :87-94
[2]   Problems in the detection and characterization of small renal masses [J].
Bosniak, MA ;
Rofsky, NM .
RADIOLOGY, 1996, 198 (03) :638-641
[3]  
BOSNIAK MA, 1986, RADIOLOGY, V158, P1
[4]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[5]  
HERMAN GT, 1980, IMAGE RECONSTRUCTION, P40
[6]   A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine [J].
Joseph, PM ;
Ruth, C .
MEDICAL PHYSICS, 1997, 24 (10) :1629-1634
[7]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]   THE ENVIRONMENTAL DENSITY ARTIFACT - A BEAM-HARDENING EFFECT IN COMPUTED-TOMOGRAPHY [J].
RAO, PS ;
ALFIDI, RJ .
RADIOLOGY, 1981, 141 (01) :223-227
[9]  
*US DHEW, 1970, RAD HLTH HAND, V2016, P137
[10]   CORRECTION FOR SCATTERED RADIATION AND OTHER BACKGROUND SIGNALS IN DUAL-ENERGY COMPUTED-TOMOGRAPHY MATERIAL THICKNESS MEASUREMENTS [J].
VETTER, JR ;
HOLDEN, JE .
MEDICAL PHYSICS, 1988, 15 (05) :726-731