Low temperature testing and neutron irradiation of a swept charge device on board the HXMT satellite

被引:6
作者
Wang Yu-Sa [1 ]
Chen Yong [1 ]
Xu Yu-Peng [1 ]
Yang Yan-Ji [1 ,2 ]
Cui Wei-Wei [1 ]
Li Mao-Shun [1 ]
Liu Xiao-Yan [1 ,2 ]
Wang Juan [1 ]
Han Da-Wei [1 ]
Chen Tian-Xiang [1 ]
Li Cheng-Kui [1 ]
Huo Jia [1 ]
Li Zheng-Wei [1 ]
Li Wei [1 ]
Hu Wei [1 ]
Zhang Yi [1 ]
Lu Bo [1 ]
Zhu Yue [1 ]
Liu Yan [1 ,3 ]
Wu Di [1 ,3 ]
Sun Qing-Rong [1 ,4 ]
Zhang Zi-Liang [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China
[2] Jilin Univ, Coll Phys, Changchun 130023, Peoples R China
[3] Yunnan Univ, Sch Phys Sci & Technol, Kunming 650091, Peoples R China
[4] Beijing Univ Chem Technol, Beijing 100029, Peoples R China
关键词
SCD; HXMT; energy resolution; readout noise; neutron irradiation; CCD;
D O I
10.1088/1674-1137/36/10/013
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
We present the low temperature testing of an SCD detector, investigating its performance such as readout noise, energy resolution at 5.9 keV and dark current. The SCD's performance is closely related to temperature, and the temperature range of -80 degrees C to -50 degrees C is the best choice, where the FWHM at 5.9 key is about 130 eV. The influence of the neutron irradiation from an electrostatic accelerator with fluence up to 1 x 10(9) cm(-2) has been examined. We find the SCD is not vulnerable to neutron irradiation. The detailed operations of the SCD and the test results of low temperature are reported, and the results of neutron irradiation are discussed.
引用
收藏
页码:991 / 995
页数:5
相关论文
共 7 条
[1]  
Barendranath S, 2010, NUCL INSTRUMENTS M A, V621, P344
[2]   X-ray CCD response functions, front to back [J].
Bautz, MW ;
Prigozhin, GY ;
Pivovaroff, MJ ;
Jones, SE ;
Kissel, SE ;
Ricker, GR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :40-52
[3]   DESIGN OF AN INTENSE FAST-NEUTRON SOURCE [J].
HEPBURN, JD ;
ORMROD, JH ;
CHIDLEY, BG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (03) :1809-1812
[4]   Direct measurement of sub-pixel structure of the EPIC MOS CCD on-board the XMM/NEWTON satellite [J].
Hiraga, J ;
Tsunemi, H ;
Short, AD ;
Abbey, AF ;
Bennie, PJ ;
Turner, MJL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (2-3) :384-393
[5]   HXMT: A Chinese high-energy astrophysics mission [J].
Li, Ti-Pei .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 166 :131-139
[6]   Proton irradiation of swept-charge devices for the Chandrayaan-1 X-ray Spectrometer (CIXS) [J].
Smith, D. R. ;
Gow, J. ;
Holland, A. D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3) :270-277
[7]   Electron and neutron radiation damage effects on a two-phase CCD [J].
Stefanov, KD ;
Tsukamoto, T ;
Miyamoto, A ;
Sugimoto, Y ;
Tamura, N ;
Abe, K ;
Nagamine, T ;
Aso, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :1280-1291