UniQua: A Universal Signal Processor for MS-Based Qualitative and Quantitative Proteomics Applications

被引:7
作者
Chang, Wei-Hung [1 ,2 ]
Lee, Chi-Ying [1 ]
Lin, Chih-Yu [1 ]
Chen, Wei-Yun [1 ]
Chen, Meng-Chieh [1 ]
Tzou, Wen-Shyong [2 ]
Chen, Yet-Ran [1 ,2 ]
机构
[1] Acad Sinica, Agr Biotechnol Res Ctr, Taipei 11529, Taiwan
[2] Natl Taiwan Ocean Univ, Keelung 20224, Taiwan
关键词
MASS-SPECTROMETRY; STATISTICAL-MODEL; AUTOMATED TOOL; SPECTRAL DATA; DIFFERENTIATION; REDUCTION; ABUNDANCE; PROTEINS; MS/MS;
D O I
10.1021/ac302281j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent developments in high resolution mass spectrometry (HR-MS) technology have ushered proteomics into a new era. However, the importance of using a common, open data platform for signal processing of HR-MS spectra has not been sufficiently addressed. In this study, a MS signal processor was developed to facilitate data integration from different instruments and different proteomics approaches into a unified platform without compromising protein identification and quantitation performance. This processor supports parallel processing capability which allows full utilization of computing resources to speed up signal processing performance to >1 gigabytes/min. The storage space occupied by the processed MS data can be reduced to similar to 10%, which helps the analysis and management of large quantities of data from comprehensive proteomics studies. For quantitation at the MS level, processing accuracy is improved and processing time for ASAPRatio is reduced to similar to 50%. For quantitation at the MS/MS level, accurate reporter ion ratios from different instruments can be directly determined by the processed MS/MS spectra and reported in the Mascot search result directly without using specialized iTRAQ software.
引用
收藏
页码:890 / 897
页数:8
相关论文
共 30 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Quantitative mass spectrometry in proteomics: a critical review [J].
Bantscheff, Marcus ;
Schirle, Markus ;
Sweetman, Gavain ;
Rick, Jens ;
Kuster, Bernhard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) :1017-1031
[3]   Visual Indicator for Surfactant Abundance in MS-Based Membrane and General Proteomics Applications [J].
Chen, Chao-Jung ;
Tseng, Mei-Chun ;
Lin, Han-Jia ;
Lin, Ting-Wei ;
Chen, Yet-Ran .
ANALYTICAL CHEMISTRY, 2010, 82 (19) :8283-8290
[4]   mzML: A single, unifying data format for mass spectrometer output [J].
Deutsch, Eric .
PROTEOMICS, 2008, 8 (14) :2776-2777
[5]   A guided tour of the Trans-Proteomic Pipeline [J].
Deutsch, Eric W. ;
Mendoza, Luis ;
Shteynberg, David ;
Farrah, Terry ;
Lam, Henry ;
Tasman, Natalie ;
Sun, Zhi ;
Nilsson, Erik ;
Pratt, Brian ;
Prazen, Bryan ;
Eng, Jimmy K. ;
Martin, Daniel B. ;
Nesvizhskii, Alexey I. ;
Aebersold, Ruedi .
PROTEOMICS, 2010, 10 (06) :1150-1159
[6]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[7]   Open mass spectrometry search algorithm [J].
Geer, LY ;
Markey, SP ;
Kowalak, JA ;
Wagner, L ;
Xu, M ;
Maynard, DM ;
Yang, XY ;
Shi, WY ;
Bryant, SH .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (05) :958-964
[8]   Quantitative profiling of differentiation-induced microsomal proteins using isotope-coded affinity tags and mass spectrometry [J].
Han, DK ;
Eng, J ;
Zhou, HL ;
Aebersold, R .
NATURE BIOTECHNOLOGY, 2001, 19 (10) :946-951
[9]   High-speed data reduction, feature detection and MS/MS spectrum quality assessment of shotgun proteomics data sets using high-resolution mass Spectrometry [J].
Hoopmann, Michael R. ;
Finney, Gregory L. ;
MacCoss, Michael J. .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5620-5632
[10]   Automated reduction and interpretation of high resolution electrospray mass spectra of large molecules [J].
Horn, DM ;
Zubarev, RA ;
McLafferty, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (04) :320-332