Overcoming issues associated with the scale-up of a continuous flow microwave system for aseptic processing of vegetable purees

被引:31
作者
Kumar, P. [1 ]
Coronel, P. [2 ]
Truong, V. D. [3 ]
Simunovic, J. [1 ]
Swartzel, K. R. [1 ]
Sandeep, K. P. [1 ]
Cartwright, G. [1 ]
机构
[1] N Carolina State Univ, Dept Food Sci, Raleigh, NC 27695 USA
[2] Unilever R&D, NL-3133 AT Vlaardingen, Netherlands
[3] N Carolina State Univ, USDA ARS, SAA Food Sci Res Unit, Raleigh, NC 27695 USA
关键词
aseptic processing; microwave heating; vegetable purees; scale-up;
D O I
10.1016/j.foodres.2007.11.004
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Continuous flow microwave heating is a promising alternative to conventional heating for aseptic processing of low-acid vegetable purees. However, non-uniform temperature distribution and control of processing parameters are the major hurdles in the implementation of continuous flow microwave heating. This study was undertaken to overcome issues associated with the scale-up of a continuous flow microwave system from pilot plant scale to industrial scale and to conduct extended run times of 8 h based on the procedure developed. Dielectric properties and cross-sectional temperature profiles were measured during processing of green pea puree and carrot puree from 20 to 130 degrees C in a 5-kW continuous flow microwave system. During processing of green peas, cross-sectional temperature differences of 8.6 and 5 degrees C were observed at the outlet for center temperatures of 50 and 130 degrees C respectively. These temperature differences were 32.9 and 3.6 degrees C for carrot puree. For process scale-up, green pea puree and carrot puree were processed in a 60-kW microwave system with the objective of successful operation for at least 8 h. Static mixers, installed at the exit of each of the microwave applicators, improved temperature uniformity for both purees. Successful completion of processing the purees for 8 h in the 60-kW microwave system showed the potential for the scale-up of a continuous flow microwave system from pilot plant scale to industrial scale. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:454 / 461
页数:8
相关论文
共 11 条
[1]  
[Anonymous], [No title captured], Patent No. 6265702
[2]  
[Anonymous], 1996, ASEPTIC PROCESSING P
[3]  
Coronel P, 2005, J FOOD SCI, V70, pE531, DOI 10.1111/j.1365-2621.2005.tb08315.x
[4]   Temperature profiles within milk after heating in a continuous-flow tubular microwave system operating at 915 MHz [J].
Coronel, P ;
Simunovic, J ;
Sandeep, KP .
JOURNAL OF FOOD SCIENCE, 2003, 68 (06) :1976-1981
[5]  
CORONEL P, 2005, THESIS N CAROLINA ST, P113
[6]  
DATTA AK, 1997, C FOOD ENG AM I CHEM, P14
[7]  
GENTRY TS, 2005, LEBENSMITTEL WISSENS, V8, P227
[8]  
GIESE J, 1992, FOOD TECHNOLOGY, V42, P118
[9]   PASTEURIZATION OF CITRUS JUICE WITH MICROWAVE-ENERGY IN A CONTINUOUS-FLOW UNIT [J].
NIKDEL, S ;
CHEN, CS ;
PARISH, ME ;
MACKELLAR, DG ;
FRIEDRICH, LM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (11) :2116-2119
[10]   Enhanced destruction of spoilage microorganisms in apple juice during continuous flow microwave heating [J].
Tajchakavit, S ;
Ramaswamy, HS ;
Fustier, P .
FOOD RESEARCH INTERNATIONAL, 1998, 31 (10) :713-722