Control Strategies for Three-Phase Three-Wire Shunt Active Filter in the Reference Frame of Two-Wattmeter Method

被引:0
作者
Artemenko, M. Yu [1 ]
Kutafin, Yu, V [1 ]
Mykhalskyi, V. M. [2 ]
Chopyk, V. V. [2 ]
Shapoval, I. A. [2 ]
Polishchuk, S. Y. [2 ]
机构
[1] Natl Tech Univ Ukraine Igor Sikorsky, Dept Acoust & Acoust Elect, Kyiv Polytech Inst, Kiev, Ukraine
[2] Natl Acad Sci Ukraine, Inst Electrodynam, Kiev, Ukraine
来源
2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO) | 2020年
关键词
instantaneous power theory; three-phase three-wire power system; control strategy for shunt active filter; POWER; DEFINITION; SYSTEMS;
D O I
10.1109/elnano50318.2020.9088885
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the active filtering theory of the three-phase power supply system was further improved by developing three new control strategies for three-wire shunt active filter (SAF) in the two-wattmeter method reference frame. The first of these forms a two-coordinate compensation current in the form of the difference between the instantaneous values of the load current and the active current, determined on the basis of modified instantaneous power theory. The second strategy directly operates with instantaneous inactive current, expressed in the two-wattmeter method reference frame. And finally, in the third strategy, the current of the load instantaneous active power ripple is added to the mentioned inactive current. The two-coordinate compensation currents of all three strategies can be formed by a two-phase three-wire SAF based on a two-phase transistor half-bridge inverter with a control system. Proposed control strategies differ from the known by increased accuracy and speed due to eliminating the dual matrix coordinate transformation, as well as by increased efficiency due to reducing the number of transistor regulators and inductors and exclusion of the resistive system of artificial ground. The results of the computer experiment confirm the adequacy of the proposed new control strategies.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 50 条
[31]   A COMPARISON OF TWO-PHASE THREE-WRE SHUNT COMPENSATION STRATEGIES [J].
Furtado, Pablo C. de S. ;
Rodrigues, Marcio do C. B. P. ;
Braga, Henrique A. C. ;
Barbosa, Pedro G. .
2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
[32]   Modeling and Resonance Control of Modular Three-Level Shunt Active Power Filter [J].
Feng, Ling ;
Wang, Yong .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) :7478-7486
[33]   Modeling and Control Design Based on Petri Nets Tool for a Serial Three-Phase Five-Level Multicellular Inverter Used as a Shunt Active Power Filter [J].
Othman, Sana ;
Alali, Mohamad Alaaeddin ;
Sbita, Lassaad ;
Barbot, Jean-Pierre ;
Ghanes, Malek .
ENERGIES, 2021, 14 (17)
[34]   Flatness-Based Control of Three-Phase Inverter With Output LC Filter [J].
Houari, Azeddine ;
Renaudineau, Hugues ;
Martin, Jean-Philippe ;
Pierfederici, Serge ;
Meibody-Tabar, Farid .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (07) :2890-2897
[35]   Simplified Feedback Linearization Control of Three-Phase Photovoltaic Inverter With an LCL Filter [J].
Bao, Xianwen ;
Zhuo, Fang ;
Tian, Yuan ;
Tan, Peixuan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2739-2752
[36]   Sliding-mode control in dq-frame for a three-phase grid-connected inverter with LCL-filter [J].
Dang, Chaoliang ;
Tong, Xiangqian ;
Song, Weizhang .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2020, 357 (15) :10159-10174
[37]   Implementation of a Control Strategy for Three-phase Four-wire VSI Parallel Connected [J].
Arbugeri, Cesar Augusto ;
Jappe, Tiago Kommers ;
Lazzarin, Telles Brunelli ;
Mussa, Samir Ahmad .
2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2014, :1043-1048
[38]   Two-channel control of three-phase inverters for distortion reduction [J].
Padmavathi, Lakshmanan ;
Janakiraman, Panapakkam Arumugam .
IET POWER ELECTRONICS, 2013, 6 (01) :192-201
[39]   Active Power Filtering for a Three-Phase Four-Wire Network with Unidentifiable Harmonic Loads [J].
Waite, M. J. ;
Zhang, L. ;
Chong, B. .
2011 2ND IEEE PES INTERNATIONAL CONFERENCE AND EXHIBITION ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT EUROPE), 2011,
[40]   Control of Three-Phase Boost-Type PWM Rectifier in Stationary Frame Under Unbalanced Input Voltage [J].
Li, Zixin ;
Li, Yaohua ;
Wang, Ping ;
Zhu, Haibin ;
Liu, Congwei ;
Xu, Wei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (10) :2521-2530