Direct Simulations of Transitional Flow in a Patient-Specific Carotid Bifurcation with Stenosis

被引:0
作者
Lee, Sang-Wook [1 ]
Lee, Seung [2 ]
Fischer, Paul F. [3 ]
Loth, Francis [4 ]
机构
[1] Univ Ulsan, Sch Mech & Automot Engn, Ulsan 680749, South Korea
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] Math & Comp Sci Div, Argonne Natl Lab, Argonne, IL USA
[4] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL USA
来源
IFOST 2008: PROCEEDING OF THE THIRD INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGIES | 2008年
关键词
Carotid artery bifurcation; stenosis; spectral element method; Turbulence; Hemodynamics;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Diseased vessels experience a significantly different biomechanical environment than healthy vessels due to the presence of transitional and turbulent flow, which may be responsible for cell damage or plaque disruption. With an objective of investigating turbulent characteristics in a diseased vessel, direct numerical simulations were conducted based on a patient-specific carotid bifurcation with a severe stenosis under pulsatile flow conditions. Computerized tomography images and color Doppler ultrasound measurements were acquired to obtain the anatomical geometry and in vivo flow waveform, respectively. The spectral element method, which is ideally suited for transitional and turbulent flow simulation, was employed in the numerical technique. Transition to turbulent flow with chaotic velocity fluctuations triggered by Kelvin-Helmholtz instabilities in the internal carotid artery was observed in the systolic phase. Turbulence intensities were significantly enhanced downstream of the stenosis during the deceleration phase of systole. The interaction of two strong shear layers generated from the bifurcation apex and distal end of stenosis as well as flow separation due to complex irregular morphology, created large WSS spatial gradients in the stenosis and high WSS magnitudes (250-450 dyne/cm(2)). Turbulent pressure fluctuations downstream of the stenosis and a large transient pressure drop occurring over the stenosis region will likely produce significant dynamic stresses-cyclic loading on plaques. Turbulent velocity and pressure fluctuations in the post-stenotic region were observed in audible frequency range of 100-300 Hz. This study demonstrates the hemodynamic environment in a diseased carotid bifurcation to be extremely complex during systolic phase and significantly different than that of a healthy carotid bifurcation.
引用
收藏
页码:475 / 479
页数:5
相关论文
共 24 条
[1]   PULSATILE POSTSTENOTIC FLOW STUDIES WITH LASER DOPPLER ANEMOMETRY [J].
AHMED, SA ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1984, 17 (09) :695-&
[2]   A fluid-structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery [J].
Bathe, M ;
Kamm, RD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :361-369
[3]   DISORDER DISTAL TO MODELED STENOSES IN STEADY AND PULSATILE FLOW [J].
CASSANOVA, RA ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1978, 11 (10-1) :441-453
[4]   HEMODYNAMICS OF AN ARTERY WITH MILD STENOSIS [J].
CAVALCANTI, S .
JOURNAL OF BIOMECHANICS, 1995, 28 (04) :387-399
[5]   Numerical investigation of the non-Newtonian blood flow in a bifurcation model with a non-planar branch [J].
Chen, J ;
Lu, XY .
JOURNAL OF BIOMECHANICS, 2004, 37 (12) :1899-1911
[6]  
DAVIES PF, 1986, P NATL ACAD SCI USA, V83, P2114, DOI 10.1073/pnas.83.7.2114
[7]   Simulation of high-Reynolds number vascular flows [J].
Fischer, Paul F. ;
Loth, Francis ;
Lee, Seung E. ;
Lee, Sang-Wook ;
Smith, David S. ;
Bassiouny, Hisham S. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2007, 196 (31-32) :3049-3060
[8]   Spectral Element Methods for Transitional Flows in Complex Geometries [J].
Fischer, Paul F. ;
Kruse, Gerald W. ;
Loth, Francis .
JOURNAL OF SCIENTIFIC COMPUTING, 2002, 17 (1-4) :81-98
[9]  
FUSTER V, 1990, CIRCULATION, V82, P47
[10]   The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model [J].
Gijsen, FJH ;
van de Vosse, FN ;
Janssen, JD .
JOURNAL OF BIOMECHANICS, 1999, 32 (06) :601-608