The critical current of Nb3Sn wires for ITER as a function of the axial tension and compression

被引:15
作者
tenHaken, B [1 ]
Godeke, A [1 ]
tenKate, HHJ [1 ]
Specking, W [1 ]
机构
[1] KFA JULICH,FORSCHUNGSZENTRUM KARLSRUHE,PHYS TECH INST,D-76021 KARLSRUHE,GERMANY
关键词
D O I
10.1109/20.511441
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of compressive and tensile axial strains on the critical current of various Nb3Sn conductors is investigated. The investigated multifilamentary wires are especially developed for the ITER project, The critical current is determined as a function of an axial tension in a standard pull set-up, These results are compared with the results that are obtained on a bending spring-type strain device, In this second device an axial compression larger than the integral thermal shrinkage of the matrix, can be achieved. A study of the field dependence of the critical current yields the strain dependence of the extrapolated upper-critical field versus the axial strain, A good correlation is found between the two different strain devices in the tensile strain regime, There is a difference in the (limited) compressive strain regime where such a comparison can be made.
引用
收藏
页码:2739 / 2742
页数:4
相关论文
共 4 条
[2]   A COMPACT-5 KN-TEST FACILITY FOR SUPERCONDUCTING CONDUCTORS CARRYING UP TO 15 KA IN MAGNETIC-FIELDS UP TO 14-T [J].
SPECKING, W ;
FLUKIGER, R .
JOURNAL DE PHYSIQUE, 1984, 45 (NC-1) :79-82
[3]  
SPECKING W, 1995, IN PRESS IEEE T SUPE
[4]  
TENHAKEN B, 1995, IN PRESS IEEE T SUPE