Seismic and Energetic Interventions on a Typical South Italy Residential Building: Cost Analysis and Tax Detraction

被引:18
作者
Formisano, Antonio [1 ]
Vaiano, Generoso [1 ]
Fabbrocino, Francesco [2 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn & Architecture, Naples, Italy
[2] Pegaso Univ, Dept Engn, Naples, Italy
关键词
masonry; seismic vulnerability; seismic retrofitting; energetic analysis; tax detraction; Sismabonus; Ecobonus; VULNERABILITY ASSESSMENT; ABRUZZI; MODEL;
D O I
10.3389/fbuil.2019.00012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Italian buildings are mainly represented by unreinforced masonry (URM) constructions, which were mostly built before 1970, often without respecting seismic design criteria. The main objective of Italian designers is, therefore, to retrofit these buildings in order to improve their safety under earthquake, as well as to preserve the memory of the ancient building art. In addition, the assessment of the building energetic efficiency is nowadays a very pressing need for designers and practitioners. Energetic efficiency represents the capacity to optimize the consumption of energy resources in order to reach prefixed requirements for the environment protection(.)This paper shows both seismic and energetic retrofitting interventions on a residential URM building typical of the constructive practice in the South Italy. Initially, the building characterization under geometrical and structural viewpoints is done. Subsequently, the seismic vulnerability verification is performed with unsatisfactory results, so requiring upgrading or retrofitting interventions. Moreover, with the aim to increase living comfort and energy efficiency, energetic upgrading interventions, aimed at decreasing the building transmittance, are proposed. Seismic and energetic interventions are then computed from the economic point of view in order to evaluate the financial contributions foreseen by the Italian 2018 Balance Law through theSismabonusandEcobonustools, respectively. Finally, the study proposes a global performance index able to take into account contemporary the seismic, energetic, and economic benefits deriving from retrofitting interventions applied on the inspected residential building.
引用
收藏
页数:15
相关论文
共 27 条
[1]   ENERGY RETROFIT OF HISTORICAL BUILDINGS: AN ITALIAN CASE STUDY [J].
Aste, N. ;
Adhikari, R. S. ;
Buzzetti, M. .
JOURNAL OF GREEN BUILDING, 2012, 7 (04) :144-165
[2]  
Bertolesi Elisa, 2017, Key Engineering Materials, V747, P134, DOI 10.4028/www.scientific.net/KEM.747.134
[3]   Predictive model for the seismic vulnerability assessment of small historic centres: Application to the inner Abruzzi Region in Italy [J].
Brando, Giuseppe ;
De Matteis, Gianfranco ;
Spacone, Enrico .
ENGINEERING STRUCTURES, 2017, 153 :81-96
[4]  
Cecchi R., 2010, GUIDELINES EVALUATIO
[5]   Numerical model upgrading of a historical masonry building damaged during the 2016 Italian earthquakes: the case study of the PodestA palace in Montelupone (Italy) [J].
Clementi, F. ;
Pierdicca, A. ;
Formisano, A. ;
Catinari, F. ;
Lenci, S. .
JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2017, 7 (05) :703-717
[6]  
Clementi F., 2018, P 10 INT MAS C MIL
[7]   The Italian guidelines for seismic risk classification of constructions: technical principles and validation [J].
Cosenza, Edoardo ;
Del Vecchio, Ciro ;
Di Ludovico, Marco ;
Dolce, Mauro ;
Moroni, Claudio ;
Prota, Andrea ;
Renzi, Emanuele .
BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (12) :5905-5935
[8]   Contemporary crustal extension in the Umbria-Marche Apennines from regional CGPS networks and comparison between geodetic and seismic deformation [J].
D'Agostino, N. ;
Mantenuto, S. ;
D'Anastasio, E. ;
Avallone, A. ;
Barchi, M. ;
Collettini, C. ;
Radicioni, F. ;
Stoppini, A. ;
Fastellini, G. .
TECTONOPHYSICS, 2009, 476 (1-2) :3-12
[9]   Simplified and refined methods for seismic vulnerability assessment and retrofitting of an Italian cultural heritage masonry building [J].
Formisano, A. ;
Marzo, A. .
COMPUTERS & STRUCTURES, 2017, 180 :13-26
[10]  
Formisano A., 2014, CIV COMP P NAPL, P106