Seismic performance of shear critical post-heated reinforced concrete square columns wrapped with FRP composites

被引:19
作者
Yaqub, M. [1 ]
Bailey, C. G. [2 ]
机构
[1] Univ Engn & Technol, Taxila, Pakistan
[2] Univ Manchester, Manchester, Lancs, England
关键词
Un-heated columns; Post-heated columns; Repair; Glass fibre reinforced polymer; Shear strength; Stiffness; Energy dissipation; Ductility; RC COLUMNS; STRENGTH; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2012.02.076
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes the results of an experimental study carried out to investigate the seismic performance of post-heated reinforced concrete square columns repaired with unidirectional glass or carbon fibre reinforced polymers (GFRPs or CFRPs). The test specimens were categorized into three groups; (a) un-heated, (b) post-heated and (c) post-heated columns repaired with GFRP or CFRP jackets. Each group consisted of two columns with a shear-span-to-depth ratio of 2.5 tested under similar conditions comprising a constant axial and a lateral cyclic load simulating earthquake loading. The main variables investigated in this experimental study were the effect of heat damaged columns, the type of fibres used for repair, the orientation of the main fibres and the peak drift ratios achieved. The seismic performance of the GFRP or CFRP wrapped post-heated columns were compared to the reference un-heated and post-heated columns through the hysteretic response, shear resistance, lateral strength, ductility, energy dissipation and stiffness degradation. The test results showed that wrapping of columns with a single layer of GFRP or CFRP notably enhanced the shear capacity, ductility, energy dissipation ability and slowed the rate of strength and stiffness degradation. It was shown that the post-heated columns regained the lateral strength up to the original level of un-heated columns wrapped with a single layer of GFRP or CFRP. However, it was also shown that the post-heated columns wrapped with a single layer of GFRP or CFRP did not restore the repaired post-heated column to the original level of stiffness of the un-heated columns. Additionally, the un-heated and post-heated columns failed in shear while the governing failure mechanism of the GFRP or CFRP wrapped post-heated columns was successfully shifted from column shear to flexural failure. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:457 / 469
页数:13
相关论文
共 33 条
[1]  
Abrams M.S., 1971, AM CONCRETE I SP 25, P33
[2]   Seismic Response of FRP-Upgraded Exterior RC Beam-Column Joints [J].
Alsayed, Saleh H. ;
Al-Salloum, Yousef A. ;
Almusallam, Tarek H. ;
Siddiqui, Nadeem A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (02) :195-208
[3]  
[Anonymous], ACI SPEC PUBL
[4]   Seismic strengthening of shear critical post-heated circular concrete columns wrapped with FRP composite jackets [J].
Bailey, C. G. ;
Yaqub, M. .
COMPOSITE STRUCTURES, 2012, 94 (03) :851-864
[5]  
Bo S, 2006, J COMPOS CONSTR, V10, P304
[6]   Residual behavior of fire-exposed reinforced concrete beams prestrengthened in flexure with fiber-reinforced polymer sheets [J].
Chowdhury, E. U. ;
Bisby, L. A. ;
Green, M. F. ;
Kodur, V. K. R. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (01) :61-68
[7]   Investigation of insulated FRP-wrapped reinforced concrete columns in fire [J].
Chowdhury, Ershad U. ;
Bisby, Luke A. ;
Green, Mark F. ;
Kodur, Venkatesh K. R. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :452-460
[8]   Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns [J].
De Luca, Antonio ;
Nardone, Fabio ;
Matta, Fabio ;
Nanni, Antonio ;
Lignola, Gian Piero ;
Prota, Andrea .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) :112-123
[9]   Post-earthquake recoverability of existing RC bridge piers retrofitted with FRP composites [J].
Fahmy, Mohamed F. M. ;
Wu, Zhishen ;
Wu, Gang .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (06) :980-998
[10]  
Flores LM, 2003, PERFORMANCE EXISTING