Diagnostic accuracy of a new point-of-care screening assay for celiac disease

被引:33
作者
Benkebil, Faiza [1 ]
Combescure, Christophe [2 ,3 ]
Anghel, Silvia I. [4 ]
Duvanel, Cecile Besson [5 ]
Schaeppi, Michela G. [6 ]
机构
[1] Vidymed, CH-1007 Lausanne, Switzerland
[2] Univ Geneva, Dept Hlth & Community Med, Div Clin Epidemiol, CH-1007 Geneva, Switzerland
[3] Univ Hosp Geneva, CH-1007 Geneva, Switzerland
[4] BioArk, R&D Dept, Augurix, CH-1870 Monthey, Switzerland
[5] BioArk, Augurix, CH-1870 Monthey, Switzerland
[6] Univ Hosp Geneva, Dept Pediat, Pediat Gastroenterol Unit, CH-1211 Geneva, Switzerland
关键词
Celiac disease; Deamidated gliadin; Total immunoglobulin A; Screening; Point-of-care assay; DEAMIDATED GLIADIN PEPTIDES; TISSUE TRANSGLUTAMINASE; EARLY-CHILDHOOD; ANTIBODIES; ANTIGLIADIN; ENDOMYSIUM; PREVALENCE; PREDICTORS; TESTS;
D O I
10.3748/wjg.v19.i31.5111
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To determine the diagnostic accuracy of a new point-of-care assay detecting anti-deamidated gliadin peptides in celiac disease (CD) patients. METHODS: One-hundred-and-twelve patients (age range: 1.8-79.2 years old) with clinical symptoms suggestive of CD and/or first-degree relatives (FDR) of CD patients (n = 66), and confirmed CD on a gluten-free diet (GFD) (n = 46), were prospectively enrolled in the study at Gastroenterology outpatient clinics for adult patients and from the Gastroenterology Consultation Ward at the Pediatric Department of the University Hospital of Geneva. Written informed consent was obtained from all subjects enrolled. The study received approval from the local ethics committee. The original CD diagnosis had been based on serum-positive IgA anti-tissue transglutaminase enzyme-linked immunosorbent assay (ELISA) (QuantaLite T, Inova Diagnostics, San Diego, CA, United States) and on biopsy results. Serum samples from all study participants were tested by the new CD lateral flow immunochromatographic assay (CD-LFIA) device, Simtomax (R) Blood Drop (Augurix SA, BioArk, Monthey, Switzerland) to detect immunoglobulin (Ig) A and IgG antibodies against de-amidated gliadin peptides. The diagnostic performance was evaluated using receiver operating characteristic curves with 95% CIs. A cut-off of 2 on the Rann colorimetric scale was used to calculate the device's sensitivity and specificity. RESULTS: CD-LFIA was highly accurate in detecting untreated celiac patients. In the group of patients with CD symptoms and/or FDR, eight new cases of CD were detected by ELISA and biopsy. All of these new cases were also correctly identified by CD-LFIA. The test yielded four false positive and four false negative results. The false positive results were all within the groups with clinical symptoms suggestive of CD and/or FDR, whereas the false negative results were all within the GFD group. The test yeld a sensitivity of 78.9% (95% CI: 54.4-93.9) and specificity of 95.7% (95% CI: 89.4-98.8), and the area under the curve reached 0.893 (95% CI: 0.798-0.988). The Kappa coefficient, calculated according to the values obtained by two readers from the same device, was of 0.96 (SE: 0.06). When the GFD patients were excluded from the analysis, the area under the curve reached 0.989 (95% CI: 0.971-1.000) and the Kappa coefficient, calculated according to the values obtained by two readers from the same device, became 0.96 (SE: 0.07). Furthermore, using the Rann scale cut-off of 2 without the GFD pa- tients, sensitivity was 100% and specificity was 93.1% (95% CI: 83.3-98.1). CONCLUSION: The new CD-LFIA rapid screening test shows good diagnostic accuracy, sensitivity and specificity, and may rule out CD in patients with CD-related symptoms. (C) 2013 Baishideng. All rights reserved.
引用
收藏
页码:5111 / 5117
页数:7
相关论文
共 28 条
[1]   Recent advances in coeliac disease [J].
Armstrong, Matthew J. ;
Robins, Gerry G. ;
Howdle, Peter D. .
CURRENT OPINION IN GASTROENTEROLOGY, 2009, 25 (02) :100-109
[2]  
Attia J., 2003, Aust Prescr, V26, P111, DOI 10.18773/austprescr.2003.082
[3]   Development of a novel rapid non-invasive screening test for coeliac disease [J].
Baldas, V ;
Tommasini, A ;
Trevisiol, C ;
Berti, I ;
Fasano, A ;
Sblattero, D ;
Bradbury, A ;
Marzari, R ;
Barillari, G ;
Ventura, A ;
Not, T .
GUT, 2000, 47 (05) :628-631
[4]   Antibodies against deamidated gliadin peptides identify adult coeliac disease patients negative for antibodies against endomysium and tissue transglutaminase [J].
Dahle, C. ;
Hagman, A. ;
Ignatova, S. ;
Strom, M. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2010, 32 (02) :254-260
[5]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[6]   Identification of tissue transglutaminase as the autoantigen of celiac disease [J].
Dieterich, W ;
Ehnis, T ;
Bauer, M ;
Donner, P ;
Volta, U ;
Riecken, EO ;
Schuppan, D .
NATURE MEDICINE, 1997, 3 (07) :797-801
[7]   Immunochromatographic Sticks for Tissue Transglutaminase and Antigliadin Antibody Screening in Celiac Disease [J].
Ferre-Lopez, Sergio ;
Ribes-Koninckx, Carmen ;
Genzor, Carlos ;
Gamen, Susana ;
Pena, Luis ;
Ortigosa, Luis ;
Mendez, Enrique .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2004, 2 (06) :480-484
[8]  
Garrote JA, 1999, EUR J CLIN INVEST, V29, P697
[9]   Accuracy of Diagnostic Antibody Tests for Coeliac Disease in Children: Summary of an Evidence Report [J].
Giersiepen, Klaus ;
Lelgemann, Monika ;
Stuhldreher, Nina ;
Ronfani, Luca ;
Husby, Steffen ;
Koletzko, Sibylle ;
Korponay-Szabo, Ilma R. .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2012, 54 (02) :229-241
[10]  
Godfrey Jonathan D, 2008, Evid Based Med, V13, P118, DOI 10.1136/ebm.13.4.118