The response of an evaporative light scattering detector for the analysis of lipids is enhanced by the addition of triethylamine and an equimolar amount of formic acid to the mobile phase. The generality of this phenomenon was demonstrated for different chromatographic techniques and various classes of lipids: for non-aqueous liquid chromatography with a porous graphitic carbon packing for wax esters, fatty acid methyl esters and ceramides; for normal phase liquid chromatography with a PVA-Sil((R)) stationary phase for cerebrosides, digalactosyl-diacylglycerols and phospholipids; and for subcritical chromatography with an octadecyl grafted silica column for ceramides. The response enhancement was quantified with cholesterol in non-aqueous liquid chromatography with a porous graphitic carbon packing. This response modifier enhances the detection response of lipids and does not significantly alter retention excepts in case of zwitterionic phospholipids.
引用
收藏
页码:607 / 611
页数:5
相关论文
共 24 条
  • [1] EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY
    CHARLESWORTH, JM
    [J]. ANALYTICAL CHEMISTRY, 1978, 50 (11) : 1414 - 1420
  • [2] Christie W.W., 1987, HPLC LIPIDS PRACTICA
  • [3] CHRISTIE WW, 1985, J LIPID RES, V26, P507
  • [4] Christie WW, 1998, PHYTOCHEM ANALYSIS, V9, P53, DOI 10.1002/(SICI)1099-1565(199803/04)9:2&lt
  • [5] 53::AID-PCA391&gt
  • [6] 3.0.CO
  • [7] 2-U
  • [8] Assessment of the retention properties of poly(vinyl alcohol) stationary phase for lipid class profiling in liquid chromatography
    Deschamps, FS
    Chaminade, P
    Ferrier, D
    Baillet, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (02) : 127 - 137
  • [9] Analysis of commercial ceramides by non-aqueous reversed-phase liquid chromatography with evaporative light-scattering detection
    Gaudin, K
    Chaminade, P
    Ferrier, D
    Baillet, A
    Tchapla, A
    [J]. CHROMATOGRAPHIA, 1999, 49 (5-6) : 241 - 248
  • [10] Improvement of evaporative light scattering detection of ceramides using triethylamine and formic acid in non-aqueous reversed phase liquid chromatography
    Gaudin, K
    Chaminade, P
    Ferrier, D
    Baillet, A
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (03) : 387 - 397