Seismic Reliability of Double-Layer Grid Space Structures

被引:0
|
作者
Salajegheh, E. [1 ]
Mansouri, I. [1 ]
机构
[1] Univ Kerman, Dept Civil Engn, Kerman, Iran
关键词
double-layer grids; performance-based design; reliability; uncertainty; incremental dynamic analysis; confidence level;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the most important tasks for today's earthquake engineers is reliable prediction of nonlinear response of structures during future earthquakes. The limitation of our information about seismic parameters such as distance from epicentre, frequency content, and amplitude characteristic as well as uncertainty imposed due to analytical models dictate the use of probability theory in the earthquake engineering assessments. In this paper, a measure of seismic demand and capacity is for space structure using incremental dynamic analysis. All analyses were performed using the OpenSees platform. Increasingly, vast use of such structural systems to cover large spans urges the structural engineers to obtain insight into their behaviour, considering the lack of a comprehensive code of practice for long span space structures. This study concerns a special type of such space structures, widely known as the double-layer grids.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Seismic Response of Shield Tunnel with Double-Layer Lining
    Guo, Xiangyu
    Cai, Qipeng
    APPLIED SCIENCES-BASEL, 2024, 14 (12):
  • [22] RANGE PROFILES OF IONS IN DOUBLE-LAYER STRUCTURES
    FINK, D
    BIERSACK, JP
    STADELE, M
    TJAN, K
    BEHAR, M
    FICHTNER, PFP
    OLIVIERI, CA
    DESOUZA, JP
    ZAWISLAK, FC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 15 (1-6): : 71 - 74
  • [23] Double-layer tensegrity grids as deployable structures
    Hanaor, A.
    International Journal of Space Structures, 1993, 8 (1-2): : 135 - 143
  • [24] Theory of interface structures in double-layer ferroelectrics
    Chew, KH
    Ishibashi, Y
    Shin, FG
    Chan, HLW
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2003, 72 (09) : 2364 - 2368
  • [25] Optimal placements of actuators in vibration active control for double-layer spherical grid shell structures
    Xiao N.
    Rong L.
    Dong S.-L.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (05): : 942 - 949+987
  • [26] Fire Behaviors of double-layer grid structures under a new temperature-time curve
    Du, Yong
    PERFORMANCE OF MATERIALS AND STRUCTURES UNDER EXTREME CONDITIONS, 2017, 210 : 605 - 612
  • [27] Seismic control of super high-rise structures with double-layer tuned particle damper
    Shen, Botan
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Yan, Weiming
    Huang, Jianhui
    Tang, Zhenyun
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (03): : 791 - 810
  • [28] Reliability evaluation of Double-layer Spherical Lattice Shell
    Li, Huijun
    Wang, Zhengzhong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 905 - 908
  • [29] RELIABILITY ANALYSIS OF DOUBLE-LAYER RIBBED CEILING PLATE
    Cheverda, P. P.
    OPIR MATERIALIV I TEORIA SPORUD-STRENGTH OF MATERIALS AND THEORY OF STRUCTURES, 2015, (96): : 123 - 129
  • [30] A new pushover procedure for estimating seismic demand of double-layer barrel vault roof with vertical double-layer walls
    Kheirollahi, Mohammad
    Abedi, Karim
    Chenaghlou, Mohammad Reza
    STRUCTURES, 2021, 34 : 1507 - 1524