Detection of visual field defects in pre-perimetric glaucoma using fundus-oriented small-target perimetry

被引:3
|
作者
Nakatani, Yusuke [1 ,2 ]
Ohkubo, Shinji [1 ]
Higashide, Tomomi [1 ]
Iwase, Aiko [3 ]
Kani, Kazutaka [4 ]
Sugiyama, Kazuhisa [1 ]
机构
[1] Kanazawa Univ, Dept Ophthalmol & Visual Sci, Grad Sch Med Sci, Kanazawa, Ishikawa 9208641, Japan
[2] Himi Municipal Hosp, Dept Ophthalmol, Himi, Japan
[3] Tajimi Iwase Eye Clin, Dept Ophthalmol, Tajimi, Japan
[4] Shiga Univ Med Sci, Otsu, Shiga 52021, Japan
基金
日本学术振兴会;
关键词
Fundus-oriented small-target perimetry; Pre-perimetric glaucoma; FREQUENCY-DOUBLING PERIMETRY; NERVE-FIBER LAYER; TEST-RETEST VARIABILITY; TECHNOLOGY PERIMETRY; AUTOMATED PERIMETRY; RAREBIT PERIMETRY; AGE; RESOLUTION; THRESHOLD; VALUES;
D O I
10.1007/s10384-012-0133-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the usefulness of automated fundus-oriented small-target perimetry in detecting glaucomatous visual field abnormalities. One eye from each of 60 normal, 37 pre-perimetric glaucoma (PPG) and 29 early stage of primary open-angle glaucoma (POAG) persons were included. The new perimeter had two monitors, one for a campimeter and the other for the examiner's operation. A test area within the central 15A degrees was set in the fundus image. The target size was 2.9 min in diameter, and the distance between the two adjacent targets was 60 min. The rate of negative response (RNR) among the age-matched controls, PPG and POAG were compared. The relationship between the RNR and age of the normal or standard automated perimetry (SAP) global indices in PPG and POAG was examined. The areas under the receiver-operating characteristic curve (AROC) to discriminate PPG or POAG versus normal were determined. The RNR increased significantly with age in normal and differed significantly (P < 0.001) among control (1.8 +/- A 1.3 %), PPG (9.2 +/- A 10.4 %) and POAG (21.2 +/- A 14.3 %). Significant correlation was found between the RNR and SAP global indices. The AROC was 0.89 for PPG and 0.95 for POAG. Fundus-oriented small-target perimetry is useful in detecting visual field abnormalities in PPG.
引用
收藏
页码:330 / 338
页数:9
相关论文
共 4 条
  • [1] Detection of visual field defects in pre-perimetric glaucoma using fundus-oriented small-target perimetry
    Yusuke Nakatani
    Shinji Ohkubo
    Tomomi Higashide
    Aiko Iwase
    Kazutaka Kani
    Kazuhisa Sugiyama
    Japanese Journal of Ophthalmology, 2012, 56 : 330 - 338
  • [2] Evaluation of additional points in the 24-2C visual field test in pre-perimetric glaucoma
    Celik, Gokhan
    Karacocuk, Tuncay
    Ciftci, Furkan
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2025, 52
  • [3] Detectability of Visual Field Defects in Glaucoma Using Moving Versus Static Stimuli for Perimetry
    Gardiner, Stuart K.
    Mansberger, Steven L.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (08):
  • [4] Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma
    Clement, C. I.
    Goldberg, I.
    Healey, P. R.
    Graham, S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 582 - 588