Determination of celiprolol in human plasma using high performance liquid chromatography with fluorescence detection for clinical application

被引:10
|
作者
Itohda, Akiko [2 ]
Tsutsumi, Kimiko [1 ]
Imai, Hiromitsu [2 ]
Iwao, Miyuki [2 ]
Kotegawa, Tsutomu [2 ]
Ohashi, Kyoichi [2 ]
机构
[1] Oita Univ, Fac Med, Dept Pharmaceut Med & Commun, Yufu, Oita 8795593, Japan
[2] Oita Univ, Fac Med, Dept Clin Pharmacol & Therapeut, Yufu, Oita 8795593, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 904卷
关键词
Celiprolol; HPLC; Solid phase extraction; Fluorescence detection; Apple juice; JUICE; TRANSPORT; (S)-CELIPROLOL; (R)-CELIPROLOL; SLCO2B1; PHASE; ASSAY;
D O I
10.1016/j.jchromb.2012.07.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method of analysis has been developed and validated for the determination of plasma celiprolol concentration. Plasma samples (1 ml) were pre-purified by solid-phase extraction with Bond Elut (R) C18. The separation was achieved with XBridge (TM) C18 column (150 mm x 3.0 mm id., 3.5 mu m) at 35 degrees C using a mixture of acetonitrile and 10 mM ammonium acetate buffer (pH 10.5) (34:66, v/v) under isocratic conditions at a flow rate of 0.4 ml/min. The peak was detected using a fluorescence detector at excitation 250 nm and emission 482 nm. Retention times for the internal standard (acebutolol) and celiprolol were 4.2 min and 6.3 min, respectively. Calibration curves were linear over the range of 1.0-1000 ng/ml (r > 0.999), with a limit of quantification at 1.0 ng/ml. Intra- and inter-assay precision (relative standard deviation) were less than 13.3% and the accuracy (relative error) was -5.1% to 11.5% at four different concentrations. This proposed method was successfully applied to a study of pharmacokinetic interactions between celiprolol and apple juice in humans. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [41] Determination of the endocannabinoid anandamide in human plasma by high-performance liquid chromatography
    Schmidt, A
    Brune, K
    Hinz, B
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (04) : 336 - 342
  • [42] Application of the high-performance liquid chromatography method with coulometric detection for determination of vitamin B6 in human plasma and serum
    Marszall, Marcin L.
    Lebiedzinska, Anna
    Czarnowski, Wojciech
    Makarowski, Ryszard
    Klos, Mateusz
    Szefer, Piotr
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 3151 - 3158
  • [43] Determination of TJ0711 hydrochloride in rat plasma by high performance liquid chromatography with fluorescence detection and its application to pharmacokinetics
    Fan, Zhaoze
    Si, Luqin
    Xu, Li
    Ma, Yiming
    Hu, Lei
    Qiu, Jun
    Li, Gao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (22): : 2035 - 2038
  • [44] Determination of free amino acids in blood plasma by high-performance liquid chromatography with fluorescence detection
    Czauderna, M
    Kowalczyk, J
    JOURNAL OF ANIMAL AND FEED SCIENCES, 1998, 7 (04): : 453 - 463
  • [45] Determination of recent antidepressant citalopram in human plasma by liquid chromatography—Fluorescence detection
    M. A. Raggi
    V. Pucci
    R. Mandrioli
    C. Sabbioni
    S. Fanali
    Chromatographia, 2003, 57 : 273 - 278
  • [46] A quantitative method for the determination of bosutinib in human plasma using high-performance liquid chromatography and ultraviolet detection
    Sumimoto, Takahiro
    Nakahara, Ryosuke
    Sato, Yuhki
    Itoh, Hiroki
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [47] A Simple, Sensitive Determination of Ganciclovir in Infant Plasma by High-Performance Liquid Chromatography with Fluorescence Detection
    Yoshida, Terumitsu
    Takahashi, Ryohei
    Imai, Koichi
    Uchida, Hiroshi
    Arai, Yasutoshi
    Oh-ishi, Tsutomu
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (03) : 208 - 211
  • [48] Determination of total aminothiols and neuroactive amino acids in plasma by high performance liquid chromatography with fluorescence detection
    Pozdeev V.K.
    Pozdeyev N.V.
    Biochemistry (Moscow) Supplement Series B: Biomedical Chemistry, 2010, 4 (3) : 288 - 295
  • [49] Determination of recent antidepressant citalopram in human plasma by liquid chromatography - Fluorescence detection
    Raggi, MA
    Pucci, V
    Mandrioli, R
    Sabbioni, C
    Fanali, S
    CHROMATOGRAPHIA, 2003, 57 (5-6) : 273 - 278
  • [50] High-Performance Liquid Chromatography Method for Determination of Diltiazem in Human Plasma
    Baviskar, Dheeraj
    Sharma, Rajesh
    Jain, Dinesh
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (07) : 5048 - 5054