Scatter Correction Method for Cone Beam CT Using Beam Attenuation Grid

被引:1
|
作者
Xie, Shipeng [1 ]
Luo, Limin [1 ]
Yang, Lifeng
Zhang, Feng [1 ]
机构
[1] Southeast Univ, Sch Comp Sci & Engn, Nanjing, Jiangsu, Peoples R China
关键词
scatter correction; Compton scatters; cone-beam computed tomography; CORRECTION ALGORITHM; MODEL; RADIOGRAPHY;
D O I
10.4028/www.scientific.net/KEM.480-481.341
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The scattering phenomenon has an important influence on the reconstructed image in Cone Beam CT (CBCT) imaging systems, and is a long-lasting research topic on CBCT. Focusing on the scatter artifact in the cone beam CT system, we proposed a new scatter correction method that needed to add a beam attenuation grid (BAG) between the X - ray source and the tested object. This study educed the scatter correction algorithm based on the Beer theorem. Through subtracting the scatter distribution image from the original projection image, we can acquire the scatter-corrected projection Images of the tested object. The method has been verified by preliminary experimental results on phantom. The result showed that the method can effectively reduce the scatter artifacts, increase the image contrast and increase the quality of the reconstructed slice image. This method is computationally efficient and easy to implement without the loss of real-time imaging capabilities.
引用
收藏
页码:341 / +
页数:3
相关论文
共 50 条
  • [21] Scatter Correction in Cone Beam CT for Metal Additive Manufacturing Components
    Xia, Xiaoqin
    Hu, Xiaodong
    Han, Zhenye
    Zhang, Dong
    Xu, Ying
    Zou, Jing
    JOM, 2019, 71 (03) : 1082 - 1087
  • [22] Scatter Correction in Cone Beam CT for Metal Additive Manufacturing Components
    Xiaoqin Xia
    Xiaodong Hu
    Zhenye Han
    Dong Zhang
    Ying Xu
    Jing Zou
    JOM, 2019, 71 : 1082 - 1087
  • [23] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    Chinese Physics B, 2014, 23 (09) : 519 - 525
  • [24] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [25] A new X-ray scatter correction method based on BAG for cone beam CT
    Geng, Ping
    Teng, Fei
    Xiao, Dayu
    Kang, Yan
    PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 326 - 329
  • [26] Scatter correction method for cone-beam CT based on interlacing-slit scan
    Huang Kui-Dong
    Zhang Hua
    Shi Yi-Kai
    Zhang Liang
    Xu Zhe
    CHINESE PHYSICS B, 2014, 23 (09)
  • [27] Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J. -M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [28] Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan
    Liang, X.
    Gong, S.
    Zhou, Q.
    Zhang, Z.
    Xie, Y.
    Niu, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3457 - 3457
  • [29] Single-scan scatter correction for cone-beam CT using a stationary beam blocker: a preliminary study
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [30] Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker in a Single Scan
    Liang, X.
    Luo, C.
    Zhang, Z.
    Xie, Y.
    Niu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E170 - E170