Scatter Correction Method for Cone Beam CT Using Beam Attenuation Grid

被引:1
作者
Xie, Shipeng [1 ]
Luo, Limin [1 ]
Yang, Lifeng
Zhang, Feng [1 ]
机构
[1] Southeast Univ, Sch Comp Sci & Engn, Nanjing, Jiangsu, Peoples R China
来源
MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2 | 2011年 / 480-481卷
关键词
scatter correction; Compton scatters; cone-beam computed tomography; CORRECTION ALGORITHM; MODEL; RADIOGRAPHY;
D O I
10.4028/www.scientific.net/KEM.480-481.341
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The scattering phenomenon has an important influence on the reconstructed image in Cone Beam CT (CBCT) imaging systems, and is a long-lasting research topic on CBCT. Focusing on the scatter artifact in the cone beam CT system, we proposed a new scatter correction method that needed to add a beam attenuation grid (BAG) between the X - ray source and the tested object. This study educed the scatter correction algorithm based on the Beer theorem. Through subtracting the scatter distribution image from the original projection image, we can acquire the scatter-corrected projection Images of the tested object. The method has been verified by preliminary experimental results on phantom. The result showed that the method can effectively reduce the scatter artifacts, increase the image contrast and increase the quality of the reconstructed slice image. This method is computationally efficient and easy to implement without the loss of real-time imaging capabilities.
引用
收藏
页码:341 / +
页数:3
相关论文
共 17 条
[1]   Cone beam X-ray scatter removal via image frequency modulation and filtering [J].
Bani-Hashemi, A ;
Blanz, E ;
Maltz, J ;
Hristov, D ;
Svatos, M .
MEDICAL PHYSICS, 2005, 32 (06) :2093-2093
[2]   SCATTER CORRECTION ALGORITHM FOR DIGITALLY ACQUIRED RADIOGRAPHS - THEORY AND RESULTS [J].
BOONE, JM .
MEDICAL PHYSICS, 1986, 13 (03) :319-328
[3]   AN ANALYTICAL MODEL OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :721-725
[4]   SCATTER COMPENSATION FOR DIGITAL CHEST RADIOGRAPHY USING MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATION [J].
FLOYD, CE ;
BAYDUSH, AH ;
LO, JY ;
BOWSHER, JE ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1993, 28 (05) :427-433
[5]   METHOD FOR ESTIMATING THE INTENSITY OF SCATTERED RADIATION USING A SCATTER GENERATION MODEL [J].
HONDA, M ;
KIKUCHI, K ;
KOMATSU, KI .
MEDICAL PHYSICS, 1991, 18 (02) :219-226
[6]  
HU DC, 2009, COMPUT TOMOGR, V18, P16
[7]   A spatially varying Compton scatter correction for SPECT utilizing the integral Klein-Nishina cross section [J].
Jonsson, C ;
Larsson, SA .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1767-1783
[8]   A REGIONAL CONVOLUTION KERNEL ALGORITHM FOR SCATTER CORRECTION IN DUAL-ENERGY IMAGES - COMPARISON TO SINGLE-KERNEL ALGORITHMS [J].
KRUGER, DG ;
ZINK, F ;
PEPPLER, WW ;
ERGUN, DL ;
MISTRETTA, CA .
MEDICAL PHYSICS, 1994, 21 (02) :175-184
[9]   X-ray scatter correction algorithm for cone beam CT imaging [J].
Ning, R ;
Tang, XY ;
Conover, D .
MEDICAL PHYSICS, 2004, 31 (05) :1195-1202
[10]   A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT [J].
Siewerdsen, JH ;
Daly, MJ ;
Bakhtiar, B ;
Moseley, DJ ;
Richard, S ;
Keller, H ;
Jaffray, DA .
MEDICAL PHYSICS, 2006, 33 (01) :187-197