Robust Control of Three-Phase VSI with LCL Filter for Distributed Generation Power Quality Improvement

被引:4
作者
Ugaz Pena, Jose Carlos [1 ]
Sampaio, Leonardo Poltronieri [2 ]
Gomes de Brito, Moacyr Aureliano [3 ]
Canesin, Carlos Alberto [1 ]
机构
[1] Sao Paulo State Univ UNESP, Power Elect Lab, Ilha Solteira, SP, Brazil
[2] Fed Univ Technol Parana UTFPR, Cornelio Procopio, PR, Brazil
[3] Fed Univ Mato Grosso do Sul UFMS, Dept Elect Engn DEL, Cidade Univ,Caixa Postal 549,S-N, BR-79070900 Campo Grande, MS, Brazil
基金
巴西圣保罗研究基金会;
关键词
Grid-connected inverter; LCL filter; Linear matrix inequalities (LMIs); Microgrid inverter; Robust control; INVERTER;
D O I
10.1007/s40313-020-00610-y
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a methodology to control a three-phase voltage source inverter with LCL filter for distributed generation (DG) in microgrid scenario. Thus, the presented control strategy allows the DG system to operate in both grid-connected and islanded modes with a smooth transition between them. Therefore, the DG control system strategy is performed by splitting the control input into two control-stages; the first one is in charge of reproducing sinusoidal voltages at the filter capacitors; meanwhile, the second is dedicated to modulate these voltages in order to achieve proper amplitude and phase for correct output current injection. By means of discrete-time state-space representation of the system, state-feedback controllers are obtained employing linear matrix inequalities considering uncertainties on grid inductances and optimization of the H2 norm for each operation mode. Finally, the feasibility of the proposed DG system is demonstrated and validated through computational simulations, as well as experimental evaluations.
引用
收藏
页码:1051 / 1062
页数:12
相关论文
共 50 条
[1]   Robust Control of Three-Phase VSI with LCL Filter for Distributed Generation Power Quality Improvement [J].
José Carlos Ugaz Peña ;
Leonardo Poltronieri Sampaio ;
Moacyr Aureliano Gomes de Brito ;
Carlos Alberto Canesin .
Journal of Control, Automation and Electrical Systems, 2020, 31 :1051-1062
[2]   Robust control of three phase VSI with LCL filter for distributed generation in microgrids enviroment [J].
Pena, Jose Carlos U. ;
Canesin, Carlos A. ;
Sampaio, Leonardo P. .
2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, :1617-1623
[3]   High Power Quality Three Phase VSI with LCL Filter for Distributed Generation in Microgrid Applications [J].
Pena, Jose Carlos U. ;
Canesin, Carlos Alberto .
PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, :848-854
[4]   Receding-Horizon Model-Predictive Control for a Three-Phase VSI With an LCL Filter [J].
Guzman, Ramon ;
Garcia de Vicuna, Luis ;
Camacho, Antonio ;
Miret, Jaume ;
Rey, Juan M. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (09) :6671-6680
[5]   A Novel Deadbeat Control for Three-Phase Grid-Connected VSI with an Output LCL Filter in Natural Frame [J].
Seyedalipour, S. Sajjad .
34TH INTERNATIONAL POWER SYSTEM CONFERENCE (PSC2019), 2019, :447-452
[6]   An Enhanced Lyapunov-Function Based Control Scheme for Three-Phase Grid-Tied VSI With LCL Filter [J].
Sefa, Ibrahim ;
Ozdemir, Saban ;
Komurcugil, Hasan ;
Altin, Necmi .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (02) :504-513
[7]   A Modified Lyapunov-Function Based Control Strategy for Three-Phase Grid-Connected VSI with LCL Filter [J].
Komurcugil, Hasan ;
Ozdemir, Saban ;
Altin, Necmi ;
Sefa, Ibrahim .
PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, :2218-2223
[8]   Simplified Feedback Linearization Control of Three-Phase Photovoltaic Inverter With an LCL Filter [J].
Bao, Xianwen ;
Zhuo, Fang ;
Tian, Yuan ;
Tan, Peixuan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2739-2752
[9]   Design Consideration of LCL-Filter for Three-Phase Voltage Source Inverter in Distributed Power Grid [J].
Peng, Yu ;
Huang, Meng ;
Sun, Jianjun ;
Zha, Xiaoming ;
Tse, Chi K. .
2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, :114-119
[10]   Fast-Transient Repetitive Control Strategy for a Three-phase LCL Filter-based Shunt Active Power Filter [J].
Zeng, Zheng ;
Yang, Jia-Qiang ;
Chen, Shi-Lan ;
Huang, Jin .
JOURNAL OF POWER ELECTRONICS, 2014, 14 (02) :392-401