Validation of an analytical method for the determination of cadmium (Cd) in fish by atomic absorption spectrometry with electrothermal atomisation

被引:4
作者
Costa, L. C. S. M.
Neto, A. P. N.
Araujo, M. Q.
Melo, M. C. C.
Furtado, D. M. S.
Kikuchi, A. N. S.
机构
[1] Laboratory of Residues and Contaminants, National Laboratory of Ministry of Agriculture, Livestock and Food Supply (LANAGRO-PA), Zip Code: 66095-000, Av. Almirante Barroso
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2012年 / 29卷 / 04期
关键词
GFAAS; heavy metals - cadmium; heavy metals; fish; PERMANENT CHEMICAL MODIFIER; LEAD; COPPER; ORGANS;
D O I
10.1080/19440049.2012.654614
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The validation of an analytical method was carried out for the determination of cadmium (Cd) in fish. The method was based on sample digestion in a microwave oven and subsequent reading using an atomic absorption spectrometer with a graphite furnace. The factorial design of experiments was applied to assess method ruggedness using the methodology of Box et al. [Box GEP, Hunter WG, Hunter JS. 1978. Statistics for experiments: an introduction to design, data analysis and model building. New York (NY): Wiley], studying the influence of sample mass, volume and concentration of acid used for sample digestion and the volume of modifier used. To study the possible matrix effect in the determination of Cd, the standard addition method was also performed. The results were treated using the OLS method. For the normality test a homoskedastic distribution was observed for the developed method and the results were adjusted to the statistical model proposed. F-tests and Student's t-tests indicated that there was no matrix effect on the calibration curve between the concentration range 1.0-10.0 mu g Cd l(-1). Parameters such as selectivity, precision, decision limit, detection capability and limit of quantification were established by the method of standard addition to blank samples. The limit of quantification was 6.8 mu g kg(-1). Accuracy, which was evaluated by using a certified reference material, was 107.0%. The recovery of the spiked analyte was 93.69% for the concentration of 50 mu g kg(-1). Precision was defined by the coefficient of variation observed (Horrat value), estimated in terms of repeatability and reproducibility, and the values were below the limit, which is 2.0. The validation procedure confirmed the suitability of the method.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [41] Development of an ultrasonic slurry sampling method for the determination of Cu and Mn in antibiotic tablets by electrothermal atomic absorption spectrometry
    de Paula, Carlos Eduardo R.
    Caldas, Luiz Fernando S.
    Brum, Daniel M.
    Cassella, Ricardo J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 197 - 203
  • [42] Development of a sensitive closed batch vessel hydride generation atomic absorption spectrometry method for the determination of cadmium in aqueous samples
    Buyukpinar, Cagdas
    Bekar, Busra
    Maltepe, Esra
    Chormey, Dotse Selali
    Turak, Fatma
    San, Nevin
    Bakirdere, Sezgin
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2018, 46 (06) : 645 - 655
  • [43] DETERMINATION OF CADMIUM AND LEAD IN AEROSOLS IN THE ZASAVJE REGION IN SLOVENIA EMPLOYING SLURRY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    MILACIC, R
    DOLINSEK, F
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1994, 57 (04) : 329 - 337
  • [44] Cloud point extraction assisted by silver nanoparticles for the determination of traces of cadmium using electrothermal atomic absorption spectrometry
    Lopez-Garcia, Ignacio
    Vicente-Martinez, Yesica
    Hernandez-Cordoba, Manuel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (02) : 375 - 380
  • [45] Feasibility of using direct determination of cadmium and lead in fresh meat by electrothermal atomic absorption spectrometry for screening purposes
    Damin, Isabel C. F.
    Silva, Marcia M.
    Vale, Maria Goreti R.
    Welz, Bemhard
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 1037 - 1045
  • [46] METHODS VALIDATION FOR DETERMINATION OF LEAD, CADMIUM AND TIN IN FRUIT JUICES BY MEANS OF GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
    Nour, V.
    Trandafir, I.
    Ionica, M. E.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2011, 12 (4A): : 2046 - 2055
  • [47] Stabilization of aviation gasoline as detergent emulsion for lead determination by electrothermal atomic absorption spectrometry
    Cassella, Ricardo J.
    Brum, Daniel M.
    Lima, Claudio F.
    Fonseca, Teresa Cristina O.
    FUEL PROCESSING TECHNOLOGY, 2011, 92 (05) : 933 - 938
  • [48] Determination of Lead in Iron Supplements by Electrothermal Atomization Atomic Absorption Spectrometry
    Barbosa, Uenderson A.
    dos Santos, Ivanice F.
    dos Santos, Ana M. P.
    Ferreira, Sergio L. C.
    ANALYTICAL LETTERS, 2016, 49 (06) : 799 - 807
  • [49] Determination of antimony in gunshot residues (GSR) by electrothermal atomic absorption spectrometry
    Fidan, N. F.
    Izgi, B.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2009, 41 (04): : 404 - 408
  • [50] Determination of lead in blood by tungsten coil electrothermal atomic absorption spectrometry
    Krug, FJ
    Silva, MM
    Oliveira, PV
    Nobrega, JA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (12) : 1469 - 1474