Validation of an analytical method for the determination of cadmium (Cd) in fish by atomic absorption spectrometry with electrothermal atomisation

被引:4
作者
Costa, L. C. S. M.
Neto, A. P. N.
Araujo, M. Q.
Melo, M. C. C.
Furtado, D. M. S.
Kikuchi, A. N. S.
机构
[1] Laboratory of Residues and Contaminants, National Laboratory of Ministry of Agriculture, Livestock and Food Supply (LANAGRO-PA), Zip Code: 66095-000, Av. Almirante Barroso
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2012年 / 29卷 / 04期
关键词
GFAAS; heavy metals - cadmium; heavy metals; fish; PERMANENT CHEMICAL MODIFIER; LEAD; COPPER; ORGANS;
D O I
10.1080/19440049.2012.654614
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The validation of an analytical method was carried out for the determination of cadmium (Cd) in fish. The method was based on sample digestion in a microwave oven and subsequent reading using an atomic absorption spectrometer with a graphite furnace. The factorial design of experiments was applied to assess method ruggedness using the methodology of Box et al. [Box GEP, Hunter WG, Hunter JS. 1978. Statistics for experiments: an introduction to design, data analysis and model building. New York (NY): Wiley], studying the influence of sample mass, volume and concentration of acid used for sample digestion and the volume of modifier used. To study the possible matrix effect in the determination of Cd, the standard addition method was also performed. The results were treated using the OLS method. For the normality test a homoskedastic distribution was observed for the developed method and the results were adjusted to the statistical model proposed. F-tests and Student's t-tests indicated that there was no matrix effect on the calibration curve between the concentration range 1.0-10.0 mu g Cd l(-1). Parameters such as selectivity, precision, decision limit, detection capability and limit of quantification were established by the method of standard addition to blank samples. The limit of quantification was 6.8 mu g kg(-1). Accuracy, which was evaluated by using a certified reference material, was 107.0%. The recovery of the spiked analyte was 93.69% for the concentration of 50 mu g kg(-1). Precision was defined by the coefficient of variation observed (Horrat value), estimated in terms of repeatability and reproducibility, and the values were below the limit, which is 2.0. The validation procedure confirmed the suitability of the method.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [31] Rapid determination of lead and cadmium in biological fluids by electrothermal atomic absorption spectrometry using Zeeman correction
    Campillo, N
    Viñas, P
    López-García, I
    Hernández-Córdoba, M
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 207 - 215
  • [32] The determination of the contamination level with lead and cadmium in sweet food samples by atomic absorption spectrometry with electrothermal atomization
    Alexiu, V
    Vladescu, L
    REVISTA DE CHIMIE, 2003, 54 (07): : 557 - 560
  • [33] Direct determination of cadmium and copper in high saline lagoon-water by electrothermal atomic absorption spectrometry
    Nevado, JJB
    Bermejo, LFG
    Martin-Doimeadios, RCR
    ANALES DE QUIMICA-INTERNATIONAL EDITION, 1997, 93 (05): : 285 - 290
  • [34] Simple and rapid determination of arsenic, lead, cadmium and tin in soft drinks by electrothermal atomic absorption spectrometry
    Tanaka, T
    Oshima, H
    Aoki, Y
    Sasaki, M
    Hayakawa, J
    Nakazawa, H
    Saito, Y
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1996, 37 (03): : 142 - 145
  • [35] Determination of Trace Cadmium in Food Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang, G. Q.
    Wen, S. P.
    Wu, X. Y.
    Liu, Y. L.
    Jiang, X. M.
    He, L. J.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (04) : 1548 - 1552
  • [36] DETERMINATION OF COPPER, IRON, ALUMINUM, LEAD AND CADMIUM IN CORK STOPPERS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    SOARES, ME
    BASTOS, ML
    FERREIRA, MA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) : 655 - 657
  • [37] Determination of trace metals in fish species of the Ria de Aveiro (Portugal) by electrothermal atomic absorption spectrometry
    Cid, BP
    Boia, C
    Pombo, L
    Rebelo, E
    FOOD CHEMISTRY, 2001, 75 (01) : 93 - 100
  • [38] Direct determination of lead, cadmium, zinc, and copper in honey by electrothermal atomic absorption spectrometry using hydrogen peroxide as a matrix modifier
    Vinas, P
    LopezGarcia, I
    Lanzon, M
    HernandezCordoba, M
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (10) : 3952 - 3956
  • [39] Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: A comparative study
    Cabon, J. Y.
    Giamarchi, P.
    Le Bihan, A.
    ANALYTICA CHIMICA ACTA, 2010, 664 (02) : 114 - 120
  • [40] Determination of cadmium and lead in wine samples by means of dispersive liquid-liquid microextraction coupled to electrothermal atomic absorption spectrometry
    Martinez, David
    Grindlay, Guillermo
    Gras, Luis
    Mora, Juan
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2018, 67 : 178 - 183