Numerical study of the influence of water evaporation on radiofrequency ablation

被引:27
|
作者
Zhu, Qing [1 ]
Shen, Yuanyuan [2 ]
Zhang, Aili [1 ]
Xu, Lisa X. [1 ]
机构
[1] Shanghai Jiao Tong Univ, MedX Res Inst, Sch Biomed Engn, State Key Lab Oncogenes & Related Genes, Shanghai 200030, Peoples R China
[2] Shenzhen Univ, Sch Med, Dept Biomed Engn, Natl Reg Key Technol Engn Lab Med Ultrasound, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Radiofrequency ablation; Water evaporation; Water diffusion; Mathematical model; TEMPERATURE DISTRIBUTION; ELECTRICAL-CONDUCTIVITY; DIELECTRIC-PROPERTIES; THERMAL-CONDUCTIVITY; TISSUE TEMPERATURE; BIOLOGICAL TISSUES; HEATING PATTERNS; SELF-DIFFUSION; RF ABLATION; TUMOR;
D O I
10.1186/1475-925X-12-127
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Radiofrequency ablation is a promising minimal invasive treatment for tumor. However, water loss due to evaporation has been a major issue blocking further RF energy transmission and correspondently eliminating the therapeutic outcome of the treatment. Method: A 2D symmetric cylindrical mathematical model coupling the transport of the electrical current, heat, and the evaporation process in the tissue, has been developed to simulate the treatment process and investigate the influence of the excessive evaporation of the water on the treatment. Results: Our results show that the largest specific absorption rate (QSAR) occurs at the edge of the circular surface of the electrode. When excessive evaporation takes place, the water dehydration rate in this region is the highest, and after a certain time, the dehydrated tissue blocks the electrical energy transmission in the radial direction. It is found that there is an interval as long as 65 s between the beginning of the evaporation and the increase of the tissue impedance. The model is further used to investigate whether purposely terminating the treatment for a while allowing diffusion of the liquid water into the evaporated region would help. Results show it has no obvious improvement enlarging the treatment volume. Treatment with the cooled-tip electrode is also studied. It is found that the cooling conditions of the inside agent greatly affect the water loss pattern. When the convection coefficient of the cooling agent increases, excessive evaporation will start from near the central axis of the tissue cylinder instead of the edge of the electrode, and the coagulation volume obviously enlarges before a sudden increase of the impedance. It is also found that a higher convection coefficient will extend the treatment time. Though the sudden increase of the tissue impedance could be delayed by a larger convection coefficient; the rate of the impedance increase is also more dramatic compared to the case with smaller convection coefficient. Conclusion: The mathematical model simulates the water evaporation and diffusion during radiofrequency ablation and may be used for better clinical design of radiofrequency equipment and treatment protocol planning.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Support adapter for radiofrequency ablation probe: Experimental study
    Ishikawa, S
    Oki, S
    Muraoka, M
    Kashiwabara, K
    Morishita, Y
    ANZ JOURNAL OF SURGERY, 2005, 75 (03) : 157 - 159
  • [32] Radiofrequency Ablation of Osteoma Osteoide: A Finite Element Study
    Irastorza, R. M.
    Trujillo, M.
    Martel Villagran, J.
    Berjano, E.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 858 - 862
  • [33] A study of the sink effect by blood vessels in radiofrequency ablation
    Zorbas, George
    Samaras, Theodoros
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 57 : 182 - 186
  • [34] Preinjected Fluids do not Benefit Microwave Ablation as Those in Radiofrequency Ablation
    Ji, Qiao
    Xu, Zuofeng
    Liu, Guangjian
    Lin, Manxia
    Kuang, Ming
    Lu, Mingde
    ACADEMIC RADIOLOGY, 2011, 18 (09) : 1151 - 1158
  • [35] Biopotential as predictor of ablation zone size during radiofrequency tumor ablation
    Schutt, D. J.
    O'Rourke, A. P.
    Will, J. A.
    Haemmerich, D.
    SCIENTIA IRANICA, 2011, 18 (06) : 1511 - 1515
  • [36] Radiofrequency ablation of renal sympathetic nerve: Numerical simulation and ex vivo experiments
    Dong, Tong
    Nan, Qun
    Tian, Zhen
    Cheng, Yanyan
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (06)
  • [37] Combined Transarterial Chemoembolization and Radiofrequency Ablation for Hepatocellular Carcinoma Infeasible for Ultrasound-Guided Percutaneous Radiofrequency Ablation: A Comparative Study with General Ultrasound-Guided Radiofrequency Ablation Outcomes
    Cha, Dong Ik
    Lee, Min Woo
    Hyun, Dongho
    Ahn, Soo Hyun
    Jeong, Woo Kyoung
    Rhim, Hyunchul
    CANCERS, 2023, 15 (21)
  • [38] Radiofrequency Ablation for Adenomyosis
    Dedes, Ioannis
    Kolovos, Georgios
    Fruscalzo, Arrigo
    Toub, David
    Vaineau, Cloe
    Lanz, Susanne
    Imboden, Sara
    Feki, Anis
    Mueller, Michael D.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)
  • [39] Thrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation?
    Lee, DSY
    Dorian, P
    Downar, E
    Burns, M
    Yeo, EL
    Gold, WL
    Paquette, M
    Lau, W
    Newman, DM
    EUROPACE, 2001, 3 (03): : 195 - 200
  • [40] Stereotactic Radiofrequency Ablation
    Bale, Reto
    Widmann, Gerlig
    Haidu, Marion
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (04) : 852 - 856