A novel needle guide system to perform percutaneous laser ablation of liver tumors using the multifiber technique

被引:25
|
作者
Di Costanzo, Giovan Giuseppe [1 ]
D'Adamo, Giuseppe [1 ]
Tortora, Raffaella [1 ]
Zanfardino, Filomena [1 ]
Mattera, Silvana [1 ]
Francica, Giampiero [2 ]
Pacella, Claudio Maurizio [3 ]
机构
[1] Cardarelli Hosp, Liver Unit, Naples, Italy
[2] Camilliani Hosp, Diagnost & Intervent Ultrasound Unit, Naples, Italy
[3] Regina Apostolorum Hosp, Albano Laziale, Italy
关键词
Ablation procedures; laser; liver; ultrasound; INDUCED INTERSTITIAL THERMOTHERAPY; SMALL HEPATOCELLULAR-CARCINOMA; RADIOFREQUENCY ABLATION; CIRRHOTIC-PATIENTS; 4; CM; METASTASES; NECROSIS; THERMOABLATION; ACHIEVEMENT; THERMOMETRY;
D O I
10.1177/0284185113489825
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Previous studies have shown that laser ablation with the multifiber technique is effective in the treatment of liver tumors. However, the correct positioning of multiple needles may be challenging. Purpose: To investigate the use of a novel needle guide system that was developed to perform percutaneous laser ablation of liver tumors with the multifiber technique under ultrasonographic guidance. Material and Methods: Between February 2009 and June 2011, 116 patients (104 hepatocellular carcinomas and 12 metastases) with 127 liver nodules (median diameter, 3.0 cm; range, 1.5-6.0) were treated. Nineteen nodules were in high-risk locations. A needle guide with separate channels to insert two needles in a parallel position and at a prefixed distance was used. Results: Needles were positioned inside the target nodule easily and quickly, and correct spacing (1.5-1.8 cm) between light sources was immediately achieved. Complete tumor ablation was achieved in a single session in 112 (88.2%) lesions. In nodules <= 3.0 cm and >3.0 cm in size, ablation was complete in 93.6% and 79.6% of cases, respectively. Of note, complete ablation was achieved in 91.7% of nodules up to 5.0 cm. Conclusion: With the new guidance system, needles could be inserted in parallel fashion, which facilitated positioning the needles in geometrical configurations to maximize the ablative effect. Worthy of note, the complete ablation rate in nodules >3.0 cm using the new guide system was higher than what has been reported in the literature so far.
引用
收藏
页码:876 / 881
页数:6
相关论文
共 17 条
  • [1] Radiofrequency Ablation of Liver Tumors: A Novel Needle Perfusion Technique Enhances Efficiency
    Abitabile, Paolo
    Maurer, Christoph A.
    JOURNAL OF SURGICAL RESEARCH, 2010, 159 (01) : 532 - 537
  • [2] Ultrasound-guided percutaneous laser and ethanol ablation of rabbit VX2 liver tumors
    Zou, Xiaojuan
    Liu, Qing
    Zhou, Xiaodong
    He, Guangbin
    Yu, Ming
    Han, Zenghui
    Meng, Xin
    Su, Haili
    ACTA RADIOLOGICA, 2013, 54 (02) : 181 - 187
  • [3] Improvement of the primary efficacy of microwave ablation of malignant liver tumors by using a robotic navigation system
    Schaible, Jan
    Pregler, Benedikt
    Verloh, Niklas
    Einspieler, Ingo
    Baeumler, Wolf
    Zeman, Florian
    Schreyer, Andreas
    Stroszczynski, Christian
    Beyer, Lukas
    RADIOLOGY AND ONCOLOGY, 2020, 54 (03) : 295 - 300
  • [4] Evaluation of a New CT-Guided Robotic System for Percutaneous Needle Insertion for Thermal Ablation of Liver Tumors: A Prospective Pilot Study
    de Baere, Thierry
    Roux, Charles
    Deschamps, Frederic
    Tselikas, Lambros
    Guiu, Boris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (11) : 1701 - 1709
  • [5] Percutaneous radiofrequency ablation of liver tumors using the LeVeen 4 cm array probe
    Pitton, MB
    Herber, S
    Raab, P
    Mönch, C
    Wunsch, M
    Schneider, J
    Schweden, F
    Otto, G
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (11): : 1525 - 1531
  • [6] Hepatocellular carcinoma: Percutaneous radiofrequency ablation using expandable needle electrodes and the double-insertion technique
    Shirato, K
    Morimoto, M
    Tomita, N
    Kokawa, A
    Sugimori, K
    Saito, T
    Tanaka, K
    HEPATO-GASTROENTEROLOGY, 2002, 49 (48) : 1481 - 1483
  • [7] MR-guided radiofrequency ablation in a 0.2-T open MR system: Technical success and technique effectiveness in 100 liver tumors
    Clasen, Stephan
    Boss, Andreas
    Schmidt, Diethard
    Schraml, Christina
    Fritz, Jan
    Schick, Fritz
    Claussen, Claus D.
    Pereira, Philippe L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1043 - 1052
  • [8] Percutaneous Microwave Ablation of Renal Tumors Using a Gas-Cooled 2.4-GHz Probe: Technique and Initial Results
    Horn, Jeremy C.
    Patel, Rahul S.
    Kim, Edward
    Nowakowski, F. Scott
    Lookstein, Robert A.
    Fischman, Aaron M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (03) : 448 - 453
  • [9] Percutaneous coaxial needle biopsy using the spacer technique: a novel and easy modification to increase procedure safety
    Coucher, JR
    Connor, P
    CLINICAL RADIOLOGY, 2005, 60 (08) : 926 - 929
  • [10] Needle track seeding after percutaneous microwave ablation of malignant liver tumors under ultrasound guidance: Analysis of 14-year experience with 1462 patients at a single center
    Yu, Jie
    Liang, Ping
    Yu, Xiao-ling
    Cheng, Zhi-gang
    Han, Zhi-yu
    Dong, Bao-wei
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2495 - 2499