Assessment of midperipheral anterior chamber depth in patient with posterior chamber phakic intraocular lens

被引:1
|
作者
Tenen, Abigail [1 ,2 ]
Roberts, Kate [1 ]
Sack, Julian [3 ]
Hodge, Chris [1 ,4 ]
机构
[1] Vis Eye Inst, Melbourne, Vic 3000, Australia
[2] Monash Univ, Melbourne, Vic 3004, Australia
[3] Royal Victoria Eye & Ear Hosp, Melbourne, Vic, Australia
[4] Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2013年 / 39卷 / 10期
关键词
IMPLANTABLE CONTACT-LENS; ULTRASOUND BIOMICROSCOPY; PUPILLARY BLOCK; HIGH MYOPIA; REPEATABILITY;
D O I
10.1016/j.jcrs.2013.07.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We describe a patient who required surgical explantation of a phakic intraocular lens (pIOL) as a result of mechanical angle closure despite the absence of standard preoperative risk factors. An assessment of the patient's records suggested peripheral anterior chamber depth (ACD) values considerably shallower than the central ACD measurement. Subsequently, the midperipheral values of all patients having pIOL implantation at our practice were reviewed to provide potential baseline measurements for comparison against the values of the explanted pIOL eyes. Assessment of midperipheral anterior chamber anatomy may be advantageous in the evaluation of patients for pIOL surgery.
引用
收藏
页码:1611 / 1614
页数:4
相关论文
共 50 条
  • [1] Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation
    Sanchez-Trancon, Angel
    Manito, Santiago Cerpa
    Sierra, Oscar Torrado
    Baptista, Antonio Manuel
    Serra, Pedro Miguel
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [2] Safety and clinical results of posterior chamber phakic intraocular lens implantation in low anterior chamber depth
    Lee, Min Gyu
    Lim, Dong Hui
    Chung, Eui Sang
    Chung, Tae-Young
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Clinical Results of Posterior Chamber Phakic Intraocular Lens Implantation in Eyes With Low Anterior Chamber Depth
    Lim, Dong Hui
    Lee, Min Gyu
    Chung, Eui-Sang
    Chung, Tae-Young
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) : 447 - 454
  • [4] Posterior chamber phakic intraocular lens
    Trindade, F
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (02) : 155 - 155
  • [5] Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens
    Takagi, Yuki
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    PLOS ONE, 2020, 15 (11):
  • [6] Phakic anterior chamber intraocular lens removal with simultaneous posterior chamber phakic intraocular lens implantation and Descemet membrane endothelial keratoplasty
    del Barrio, Jorge L. Alio
    Medalle, Ronald Steven, II
    Pederzolli, Matteo
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2024, 14 (01) : 117 - 120
  • [7] Posterior chamber intraocular lens in the anterior chamber
    Zinkernagel, M.
    Ammann-Rauch, D.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2007, 224 (04) : 309 - 310
  • [8] Posterior chamber phakic intraocular lens for hyperopia
    Sanders, DR
    Martin, RG
    Brown, DC
    Shepherd, J
    Deitz, MR
    DeLuca, MC
    JOURNAL OF REFRACTIVE SURGERY, 1999, 15 (03) : 309 - 315
  • [9] Posterior chamber silicone phakic intraocular lens
    Marinho, A
    Neves, MC
    Pinto, MC
    Vaz, F
    JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (03): : 219 - 222
  • [10] The STAAR posterior chamber phakic intraocular lens
    Zaldivar, R
    Oscherow, S
    Ricur, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 237 - 244