Seismic performance of bolted beam-to-column connection with rib-stiffened splicing plate

被引:18
作者
Liu, Xue-Chun [1 ,2 ]
Wang, Yue [1 ]
Cui, Xiao-Xiong [1 ]
Yu, Cheng [3 ]
Bai, Zheng-Xian [1 ,2 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] Univ North Texas, Dept Engn Technol, Denton, TX 76207 USA
基金
中国国家自然科学基金;
关键词
Full-bolted connection; Beam-to-column connection; Rib-stiffened splicing plate; Seismic performance; Trapezoidal stiffener; On-site assembly; MOMENT CONNECTIONS; CYCLIC BEHAVIOR; STEEL; JOINTS; BUILDINGS; DESIGN;
D O I
10.1016/j.jcsr.2020.106300
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A bolted beam-to-column connection with rib-stiffened splicing plates is presented to facilitate on-site assembly and enhance the stiffness of joints. The joints consist of three modules and are assembled using bolts on site. Cyclic tests and a finite element analysis (FEA) are performed on seven full-scale joints. The influence of the trapezoidal stiffener's size, end-plate connection type, and the number of bolts on the seismic performance of the joints is investigated. The seismic performance of the bolted joints is compared with that of a welded joint. The failure mode, hysteretic curve, energy dissipation capacity, ductility, rotation capacity, bolt tension, friction, strength, and stiffness of the joints are determined via the tests and FEA. The trapezoidal stiffener significantly improves the bearing capacity, stiffness, and energy-dissipation capacity of the joints, making the plastic hinge occur on the beam flange outside the splicing zone. It is preferable to move the web bolts to the beam flange for improved seismic performance. The bolts on the four corners of the column flange have little effect on the seismic performance; thus, the bolts can be eliminated and the flange can be substituted by four small plates to reduce cost. This reasonable design could prevent the slipping of the joint during small-magnitude earthquakes, facilitate energy dissipation via slip during medium-magnitude earthquakes, and facilitate energy dissipation via the slip and plastic deformation of the beams during large-magnitude earthquakes. The formula for the ultimate load is presented, and the corresponding calculation results agree well with the test results. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Seismic performance of bolted connection between H-section beam and SST column welded with inclined braces
    Liu, Xue-Chun
    Wu, Xiaotong
    Wang, Yue
    Cui, XiaoXiong
    JOURNAL OF BUILDING ENGINEERING, 2022, 61
  • [32] A novel ductile connection for FRP pultruded beam-to-column assemblies
    Ascione, Francesco
    D'Aniello, Mario
    Feo, Luciano
    Granata, Luigi
    Landolfo, Raffaele
    COMPOSITE STRUCTURES, 2024, 337
  • [33] Ultimate behaviour of bolted beam-to-column connections in large rotations
    Francavilla, Antonella B.
    Latour, Massimo
    Tan, P. J.
    Rizzano, Gianvittorio
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 208
  • [34] A review of the seismic performance behaviour of hybrid precast beam-to-column connections
    Ghayeb, Haider Hamad
    Sulong, N. H. Ramli
    Razak, Hashim Abdul
    Mo, Kim Hung
    Ismail, Zubaidah
    Hashim, Huzaifa
    Gordan, Meisam
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2022, 23 (01)
  • [35] Seismic performance of castellated beam-to-column end-plate joints with dual hinge mechanism
    Bi, Ran
    Xu, Feng
    Jia, Lianguang
    Wang, Qinghe
    Wang, Chungang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (12): : 56 - 71
  • [36] Bolted large seismic steel beam-to-column connections Part 1: experimental study
    Popov, EP
    Takhirov, SM
    ENGINEERING STRUCTURES, 2002, 24 (12) : 1523 - 1534
  • [37] Development and Seismic Behavior of Precast Concrete Beam-to-Column Connections
    Guan, Dongzhi
    Jiang, Cheng
    Guo, Zhengxing
    Ge, Hanbin
    JOURNAL OF EARTHQUAKE ENGINEERING, 2018, 22 (02) : 234 - 256
  • [38] Seismic performance of bolted connection between T-shaped section column and I-section beam with L-stubs
    Liu, Xue-Chun
    Meng, Kun
    Chen, Xuesen
    Li, Yong-Mei
    Cui, Yue
    ENGINEERING STRUCTURES, 2023, 285
  • [39] Seismic behavior of TOBs bolted endplate connection to strengthened CFST column
    Cai, Min
    Sun, Lele
    Wang, Qishuai
    Wang, Peijun
    Zhang, Wenchao
    Liu, Mei
    Zhai, Guangjun
    Liu, Fang Zhou
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 197
  • [40] Seismic pre-qualification tests of EC8-compliant external extended stiffened end-plate beam-to-column joints
    D'Aniello, Mario
    Tartaglia, Roberto
    Landolfo, Raffaele
    Jaspart, Jean-Pierre
    Demonceau, Jean-Francois
    ENGINEERING STRUCTURES, 2023, 291