Seismic performance of bolted beam-to-column connection with rib-stiffened splicing plate

被引:18
作者
Liu, Xue-Chun [1 ,2 ]
Wang, Yue [1 ]
Cui, Xiao-Xiong [1 ]
Yu, Cheng [3 ]
Bai, Zheng-Xian [1 ,2 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] Univ North Texas, Dept Engn Technol, Denton, TX 76207 USA
基金
中国国家自然科学基金;
关键词
Full-bolted connection; Beam-to-column connection; Rib-stiffened splicing plate; Seismic performance; Trapezoidal stiffener; On-site assembly; MOMENT CONNECTIONS; CYCLIC BEHAVIOR; STEEL; JOINTS; BUILDINGS; DESIGN;
D O I
10.1016/j.jcsr.2020.106300
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A bolted beam-to-column connection with rib-stiffened splicing plates is presented to facilitate on-site assembly and enhance the stiffness of joints. The joints consist of three modules and are assembled using bolts on site. Cyclic tests and a finite element analysis (FEA) are performed on seven full-scale joints. The influence of the trapezoidal stiffener's size, end-plate connection type, and the number of bolts on the seismic performance of the joints is investigated. The seismic performance of the bolted joints is compared with that of a welded joint. The failure mode, hysteretic curve, energy dissipation capacity, ductility, rotation capacity, bolt tension, friction, strength, and stiffness of the joints are determined via the tests and FEA. The trapezoidal stiffener significantly improves the bearing capacity, stiffness, and energy-dissipation capacity of the joints, making the plastic hinge occur on the beam flange outside the splicing zone. It is preferable to move the web bolts to the beam flange for improved seismic performance. The bolts on the four corners of the column flange have little effect on the seismic performance; thus, the bolts can be eliminated and the flange can be substituted by four small plates to reduce cost. This reasonable design could prevent the slipping of the joint during small-magnitude earthquakes, facilitate energy dissipation via slip during medium-magnitude earthquakes, and facilitate energy dissipation via the slip and plastic deformation of the beams during large-magnitude earthquakes. The formula for the ultimate load is presented, and the corresponding calculation results agree well with the test results. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Seismic performance of beam-column connections with welded upper flange and bolted lower flange
    Yu, Yousheng
    Zhang, Aijia
    Pan, Wei
    Mou, Ben
    Liu, Xinyu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 182
  • [22] Seismic performance of welded-bolted joint between double channel beam and CFST column
    Liu, Xue-chun
    Tao, Yong-li
    Chen, Xuesen
    Cui, Fu-yuan
    ENGINEERING STRUCTURES, 2021, 247
  • [23] Seismic Performance of Welded Steel Beam-to-Column Connections with Initial Weld Defects
    Li, Jiaming
    Yu, Haoran
    Li, Weibin
    Cheng, Weijia
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2022, 22 (02) : 566 - 584
  • [24] Performance of a Ductile Hybrid Post-Tensioned Beam-to-Column Connection for Precast Concrete Frames under Seismic Loads: A Review
    Mohammed, Khaleel
    Jameel, M.
    Ibrahim, Zainah
    Tan, Chee Ghuan
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [25] Cold-formed steel beam-to-column bolted connections for seismic applications
    Papargyriou, Ioannis
    Mojtabaei, Seyed Mohammad
    Hajirasouliha, Iman
    Becque, Jurgen
    Pilakoutas, Kypros
    THIN-WALLED STRUCTURES, 2022, 172
  • [26] A component method for cold-formed steel beam-to-column bolted gusset plate joints
    Bucmys, Zilvinas
    Daniunas, Alfonsas
    Jaspart, Jean-Pierre
    Demonceau, Jean-Francois
    THIN-WALLED STRUCTURES, 2018, 123 : 520 - 527
  • [27] Rib-reinforced moment connection of steel beam to box column
    Kian, Ali Reza Tolou
    Deylami, Ardeshir
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2019, 172 (06) : 407 - 421
  • [28] INFLUENCE OF THE CYCLIC BEHAVIOUR OF BEAM-TO-COLUMN CONNECTION ON THE SEISMIC RESPONSE OF REGULAR STEEL FRAMES
    Montuori, Rosario
    Nastri, Elide
    Piluso, Vincenzo
    Troisi, Marina
    INGEGNERIA SISMICA, 2016, 33 (1-2): : 91 - 106
  • [29] Bolted beam-to-column connection with buckling-restrained round steel bar dampers
    Tagawa, Hiroshi
    Nagoya, Yuta
    Chen, Xingchen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 169 (169)
  • [30] Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior
    Vatansever, Cuneyt
    Kutsal, Kutay
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (06) : 767 - 778