Physico-Chemical Analysis of Wastewater Discharge from Selected Paint Industries in Lagos, Nigeria

被引:145
作者
Aniyikaiye, Tolulope E. [1 ]
Oluseyi, Temilola [2 ]
Odiyo, John O. [3 ]
Edokpayi, Joshua N. [3 ]
机构
[1] Univ Venda, Sch Environm Sci, Private Bag X5050, ZA-0950 Thohoyandou, South Africa
[2] Univ Lagos, Dept Chem, Fac Sci, Lagos 100123, Nigeria
[3] Univ Venda, Dept Hydrol & Water Resources, Private Bag X5050, ZA-0950 Thohoyandou, South Africa
关键词
wastewater treatment; paint industries; percentage efficiency; biochemical oxygen demand; HEAVY-METALS; REMOVAL; NICKEL;
D O I
10.3390/ijerph16071235
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effluents from the paint industry have been a major source of environmental pollution. There is a need to investigate the compliance of wastewater discharged from paint industries with regulatory standards. In response, this study evaluates the physicochemical parameters of both raw and treated wastewater, the wastewater treatment plants (WWTPs) efficiencies as well as the compliance level of five selected paint manufacturing companies in Lagos, Nigeria with some regulatory standards: Federal Ministry of Environment (FME) in Nigeria, World Health Organization (WHO) and Department of Water Affairs (DWA) in South Africa. All parameters investigated were analysed using standard methods. The values of pH, electrical conductivity (EC) and total dissolved solids (TDS) levels were in the range of 4-12.2, 149.1-881.3 mS/m and 1100-6510 mg/L, respectively. The range of other parameters include total suspended solids (TSS); 0-2470 mg/L, TS; 1920-6510 mg/L, chloride; 63.8-733.8 mg/L, dissolved oxygen (DO); 0-6.7 mg/L, oil and grease (O & G); 44-100 mg/L, biochemical oxygen demand (BOD); 162.8-974.7 mg/L, chemical oxygen demand (COD); 543-1231 mg/L, nitrates;12.89-211.2 mg/L, phosphate; below detection limit (bdl)-0.02 mg/L, sulphate; 195-1434 mg/L, nickel; bdl-1.9 mg/L while copper, lead and chromium were below detection limits. The results indicated that the WWTPs of the studied paint companies were ineffective in reducing the TS, TSS, BOD, COD and (O & G) to acceptable limits. Routine monitoring of wastewater from paint industries is therefore recommended to prevent the risk of contamination to the receiving watershed which many communities rely on as source for domestic water.
引用
收藏
页数:17
相关论文
共 43 条
[21]  
Ganoulis J., 2009, Risk Analysis of Water Pollution, V2nd, P1
[22]  
Javedl M, 2013, INT J AGRIC BIOL, V15, P575
[23]  
Julian K.T., 2018, CONTAMINATED GROUNDW, P25
[24]   Physico-chemical analysis of the industrial effluents and their impact on the soil microflora [J].
Kaur, Arminder ;
Vats, Siddharth ;
Rekhi, Sumit ;
Bhardwaj, Ankit ;
Goel, Jharna ;
Tanwar, Ranjeet S. ;
Gaur, Komal. K. .
INTERNATIONAL CONFERENCE ON ECOLOGICAL INFORMATICS AND ECOSYSTEM CONSERVATION (ISEIS 2010), 2010, 2 :595-599
[25]   Treatment of wastewater from water based paint industries using submerged attached growth reactor [J].
Krithika, D. ;
Philip, Ligy .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2016, 107 :31-41
[26]  
Malakootian M, 2009, INT J ENVIRON SCI TE, V6, P183
[27]   Effects of waterborne nickel on the physiological and immunological parameters of the Pacific abalone Haliotis discus hannai during thermal stress [J].
Min, Eun Young ;
Cha, Yong-Joo ;
Kang, Ju-Chan .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (17) :13546-13555
[28]  
Ohioma AI., 2009, Journal of Toxicology and Environmental Health Sciences, V1, P34
[29]  
Olaniyi I., 2012, Archives of Applied Science Research, V4, P406
[30]  
Onuegbu TU., 2013, INT J SCI TECHNOL, V2, P169