REMOVAL OF LEAD FROM INDUSTRIAL WASTEWATER BY ELECTROCOAGULATION USING SACRIFICIAL ALUMINIUM ELECTRODES

被引:0
作者
Fogarasi, Szabolcs [1 ]
Imre-Lucaci, Florica [2 ]
Ghirisan, Adina [1 ]
Misca, Barbu Radu Horatiu [1 ]
Imre-Lucaci, Arpad [1 ,3 ]
机构
[1] Univ Babes Bolyai, Fac Chem & Chem Engn, 11 Arany Janos St, RO-400028 Cluj Napoca, Romania
[2] Univ Babes Bolyai, Physicochem Anal Ctr, Interdisciplinary Res Inst Bionanosci, 42 Treboniu Laurian St, RO-400271 Cluj Napoca, Romania
[3] Univ Babes Bolyai, Res Inst Sustainabil & Disaster Management Based, 30 Fantanele St, RO-400294 Cluj Napoca, Romania
来源
STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA | 2016年 / 61卷 / 03期
关键词
lead contamination; sacrificial Al electrodes; lead removal; electrocoagulation; HEAVY-METALS; HEALTH-RISK; COPPER; ZINC; CHINA;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of this study was to develop an ecological method for the removal of Pb2+ ions from industrial wastewater. The electrocoagulation (EC) process of Pb2+ has been studied, using an electrolytic flow cell (flow rate of 20, 40, 60 mL/min) equipped with sacrificial Al electrodes, operated under galvanostatic mode (current density of 5, 10 and 15 mA/cm(2)). In all experimental conditions the concentration of Pb2+ was lowered below the maximum allowable concentration (0.5 ppm). The experimental results showed that the performances of the process are more strongly dependent on the applied current density than on the applied flow rate. The electrolytic flow cell has proved to be quite effective, allowing the complete removal of lead with a specific energy consumption of 3.08 kWh/kg Pb removed.