Prevention of Aluminum Corrosion in Hydrochloric Acid Using Expired Oseltamivir Drug as an Inhibitor

被引:3
|
作者
Raghavendra, Narasimha [1 ]
Hubikar, Leena V. [1 ]
Ganiger, Pooja J. [1 ]
Bhinge, Anjali S. [1 ]
机构
[1] KLE Soc PC Jabin Sci Coll Autonomous, Dept Chem, Vijayanagar 580031, Hubballi, India
关键词
Expired Oseltamivir drug; Potentiodynamic polarization; AC impedance spectroscopy; Weight loss; Scanning electron microscopy; MILD-STEEL; DERIVATIVES; PROTECTION; EXTRACT; MEDIA;
D O I
10.1007/s11668-020-01005-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Oseltamivir drug is one of the most commonly employed antiviral drug and it is used to treat the influenza A and influenza B. However, Oseltamivir drug is not consumed and thrown as a waste product after its expired date. The main reason is the effectiveness of expired Oseltamivir drug declines with time, but retains its potential property after its expiration date. It is true that the effectiveness of a drug may decrease over the time, but much of the original potency still remains even a decade after the expiration date. Surprisingly, expired Oseltamivir drug contains N, O and double bonds, which have not been properly exposed for the several industrial units in order to prevent the aluminum dissolution process. With idea of using waste product and exploring non-toxic corrosion inhibitor, the expired Oseltamivir drug of four different amounts have been prepared and thoroughly screened with the aid of theoretical and experimental tools. This article appraises the corrosion protection property of expired Oseltamivir drug on the aluminum in 3 HCl solution. The corrosion inhibition behavior of expired Oseltamivir drug on aluminum metal in 3 M HCl system was studied by weight loss, atomic absorption spectroscopy, potentiodynamic polarization, AC impedance spectroscopy, quantum chemical, scanning electron microscopy, and energy-dispersive x-ray spectroscopy techniques. The expired Oseltamivir drug protects the aluminum corrosion from the 3 M HCl solution with contact time and concentration of expired drug dependent mode. The optimum protection efficiency value obtained at 2 mg/L of expired drug. The results show that expired Oseltamivir drug is effective in reduction of corrosion of aluminum. This article provides the novel information on the possible utilization of expired drug as a non-toxic corrosion inhibitor. The probable mechanism of the protection action is also given.
引用
收藏
页码:1864 / 1874
页数:11
相关论文
共 50 条
  • [1] Prevention of Aluminum Corrosion in Hydrochloric Acid Using Expired Oseltamivir Drug as an Inhibitor
    Narasimha Raghavendra
    Leena V. Hubikar
    Pooja J. Ganiger
    Anjali S. Bhinge
    Journal of Failure Analysis and Prevention, 2020, 20 : 1864 - 1874
  • [2] Expired Desloratidine Drug as Inhibitor for Corrosion of Carbon Steel Pipeline in Hydrochloric acid Solution
    Eid, Salah
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 9
  • [3] Expired Drug (pantoprazole sodium) as a Corrosion Inhibitor for High Carbon Steel in Hydrochloric Acid Solution
    Fouda, A. S.
    Ibrahim, H.
    Rashwaan, S.
    El-Hossiany, A.
    Ahmed, R. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (07): : 6327 - 6346
  • [4] Studies on the inhibition of carbon steel corrosion in hydrochloric acid solution by expired Carvedilol drug
    Fouda, A. S.
    El Morsi, M. A.
    El Mogy, T.
    GREEN CHEMISTRY LETTERS AND REVIEWS, 2017, 10 (04) : 336 - 345
  • [5] Expired Voltaren Drugs as Corrosion Inhibitor for Aluminium in Hydrochloric Acid
    Hameed, R. S. Abdel
    Ismail, E. A.
    Abu-Nawwas, A. H.
    Al-Shafey, Hussin I.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (03): : 2098 - 2109
  • [6] Corrosion inhibition of mild steel in hydrochloric acid solution by the expired Ampicillin drug
    Alamry, Khalid A.
    Khan, Ajahar
    Aslam, Jeenat
    Hussein, Mahmoud A.
    Aslam, Ruby
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Expired Abacavir Sulfate Drug as Non-toxic Corrosion Inhibitor for Mild Steel (MS) in 3 M Hydrochloric Acid System
    Raghavendra, Narasimha
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2019, 32 (04): : 1113 - 1121
  • [8] Electrochemical Techniques for Evaluation of Expired Megavit Drugs as Corrosion Inhibitor for Steel in Hydrochloric Acid
    Hameed, Reda S. Abdel
    Aljohani, Meshari M.
    Essa, Ayham Bani
    Khaled, Azaa
    Nassar, Amr M.
    Badr, Magd M.
    Al-Mhyawi, Saedah R.
    Soliman, Mahmoud S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 1 - 12
  • [9] Expired Lorazepam Drug: A Medicinal Compound as Green Corrosion Inhibitor for Mild Steel in Hydrochloric Acid System
    Raghavendra, Narasimha
    CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2019, 2 (03): : 463 - 470
  • [10] Corrosion Inhibition Efficiency of Expired Nitazoxanide Drug on Carbon Steel in Hydrochloric Acid Solution
    Motawea, M. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6682 - 6698