Large volume sample stacking of antiepileptic drugs in counter current electrophoresis performed in PAMAPTAC coated capillary

被引:18
作者
Tuma, Petr [1 ]
Hlozek, Tomas [1 ,2 ]
Sommerova, Blanka [1 ]
Koval, Dusan [3 ]
机构
[1] Charles Univ Prague, Fac Med 3, Dept Hyg, Ruska 87, Prague 10000 10, Czech Republic
[2] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Studentska 573, Pardubice 53210, Czech Republic
[3] Czech Acad Sci, Inst Organ Chem & Biochem, Flemingovo 2, Prague 16610 6, Czech Republic
关键词
Antiepileptic; Capillary electrophoresis; Coating; Contactless conductivity detection; Sample pretreatment; Serum; Stacking; ELECTROOSMOTIC FLOW PUMP; GAMMA-AMINOBUTYRIC-ACID; CONDUCTIVITY DETECTION; SENSITIVE DETERMINATION; ZONE-ELECTROPHORESIS; HUMAN SERUM; PREGABALIN; GABAPENTIN; VIGABATRIN; DERIVATIZATION;
D O I
10.1016/j.talanta.2020.121626
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrophoretic stacking is developed for sensitive determination of three zwitterionic antiepileptics, namely vigabatrin, pregabalin and gabapentin, in human serum. CE separation is performed in a 25 mu m fused silica capillary covalently coated with the copolymer of acrylamide with 5% content of permanently charged 3-acryl-amidopropyl trimethylammonium chloride (PAMAPTAC). In background electrolyte of 500 mM acetic acid, the 5% PAMAPTAC generates an anodic electm-osmotic flow with a magnitude of (-18.6 +/- 0.5) x 10(-9) m(2)V(-1)s(-1), which acts against the direction of the electrophoretic migration of the analytes. A sample of the antiepileptic prepared in a 25% v/v infusion solution and 75% v/v acetonitrile is injected into the capillary in a large volume attaining a zone length of up to 270 mm. After turning on the separation voltage, the antiepileptics are isotachophoretically focussed behind the zone of Na+ ions with a sensitivity enhancement factor of 78. For the clinical determination of antiepileptics, the human serum is diluted with acetonitrile in a ratio of 1:3 v/v and a zone with a length of 90 mm is injected into the capillary. The method is linear in the 0.025-2.5 mu g/mL concentration range; the attained limit of quantification is in the range 18.3-22.8 nmol/L; the within-day precision for the migration time is 0.8-1.2% and for the peak area 1.5-2.4%.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Field-amplified sample stacking capillary electrophoresis with electrochemiluminescence applied to the determination of illicit drugs on banknotes
    Xu, Yuanhong
    Gao, Ying
    Wei, Hui
    Du, Yan
    Wang, Erkang
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1115 (1-2) : 260 - 266
  • [42] Highly Sensitive Analysis in Capillary Electrophoresis Using Large-volume Sample Stacking with an Electroosmotic Flow Pump Combined with Field-amplified Sample Injection
    Fumihiko Kitagawa
    Shinichiro Wakagi
    Yuuki Takegawa
    Isoshi Nukatsuka
    Analytical Sciences, 2019, 35 : 889 - 893
  • [43] Large-volume sample stacking with polarity switching for monitoring of nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) reactions by capillary electrophoresis
    Lee, Sang-Yong
    Mueller, Christa E.
    ELECTROPHORESIS, 2014, 35 (06) : 855 - 863
  • [44] Combination of large volume sample stacking and dynamic pH junction for on-line preconcentration of weak electrolytes by capillary electrophoresis in comparison with isotachophoretic techniques
    Horakova, Jana
    Petr, Jan
    Maier, Vitezslav
    Znaleziona, Joanna
    Stanová, Andrea
    Marak, Jozef
    Kaniansky, Dusan
    Sevcik, Juraj
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (02) : 193 - 198
  • [45] Capillary electrophoresis coupled to MALDI mass spectrometry imaging with large volume sample stacking injection for improved coverage of C. borealis neuropeptidome
    DeLaneya, Kellen
    Li, Lingjun
    ANALYST, 2020, 145 (01) : 61 - 69
  • [46] Large-Volume Sample Staking of Rice Polyphenols Prior to Their Determination by Non-aqueous Capillary Electrophoresis
    Parveen, Sajida
    Memon, Saima Q.
    Siyal, Ali N.
    Memon, Najma
    Khuhawar, Muhammad Y.
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2152 - 2160
  • [47] Sensitive detection of piperazinyl phenothiazine drugs by field-amplified sample stacking in capillary electrophoresis with dispersive liquid-liquid microextraction
    Tu, Yi-Yi
    Hsieh, Ming-Mu
    Chang, Sarah Y.
    ELECTROPHORESIS, 2015, 36 (21) : 2828 - 2836
  • [48] On-line Sample Preconcentration by Large-volume Sample Stacking with an Electroosmotic Flow Pump (LVSEP) in Microscale Electrophoresis
    Kitagawa, Fumihiko
    Kawai, Takayuki
    Otsuka, Koji
    ANALYTICAL SCIENCES, 2013, 29 (12) : 1129 - 1139
  • [49] On-line Sample Preconcentration by Large-volume Sample Stacking with an Electroosmotic Flow Pump (LVSEP) in Microscale Electrophoresis
    Fumihiko Kitagawa
    Takayuki Kawai
    Koji Otsuka
    Analytical Sciences, 2013, 29 : 1129 - 1139
  • [50] Highly Sensitive In-Capillary Derivatization and Field Amplified Sample Stacking to Analyze Narcotic Drugs in Human Serum by Capillary Zone Electrophoresis
    Malak, Monika
    Ebrahim, Hager
    Sonbol, Heba
    Ali, Ahmed
    Aboulella, Yasmine
    Hadad, Ghada
    Emara, Samy
    SEPARATIONS, 2023, 10 (01)