Large volume sample stacking of antiepileptic drugs in counter current electrophoresis performed in PAMAPTAC coated capillary

被引:18
作者
Tuma, Petr [1 ]
Hlozek, Tomas [1 ,2 ]
Sommerova, Blanka [1 ]
Koval, Dusan [3 ]
机构
[1] Charles Univ Prague, Fac Med 3, Dept Hyg, Ruska 87, Prague 10000 10, Czech Republic
[2] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Studentska 573, Pardubice 53210, Czech Republic
[3] Czech Acad Sci, Inst Organ Chem & Biochem, Flemingovo 2, Prague 16610 6, Czech Republic
关键词
Antiepileptic; Capillary electrophoresis; Coating; Contactless conductivity detection; Sample pretreatment; Serum; Stacking; ELECTROOSMOTIC FLOW PUMP; GAMMA-AMINOBUTYRIC-ACID; CONDUCTIVITY DETECTION; SENSITIVE DETERMINATION; ZONE-ELECTROPHORESIS; HUMAN SERUM; PREGABALIN; GABAPENTIN; VIGABATRIN; DERIVATIZATION;
D O I
10.1016/j.talanta.2020.121626
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrophoretic stacking is developed for sensitive determination of three zwitterionic antiepileptics, namely vigabatrin, pregabalin and gabapentin, in human serum. CE separation is performed in a 25 mu m fused silica capillary covalently coated with the copolymer of acrylamide with 5% content of permanently charged 3-acryl-amidopropyl trimethylammonium chloride (PAMAPTAC). In background electrolyte of 500 mM acetic acid, the 5% PAMAPTAC generates an anodic electm-osmotic flow with a magnitude of (-18.6 +/- 0.5) x 10(-9) m(2)V(-1)s(-1), which acts against the direction of the electrophoretic migration of the analytes. A sample of the antiepileptic prepared in a 25% v/v infusion solution and 75% v/v acetonitrile is injected into the capillary in a large volume attaining a zone length of up to 270 mm. After turning on the separation voltage, the antiepileptics are isotachophoretically focussed behind the zone of Na+ ions with a sensitivity enhancement factor of 78. For the clinical determination of antiepileptics, the human serum is diluted with acetonitrile in a ratio of 1:3 v/v and a zone with a length of 90 mm is injected into the capillary. The method is linear in the 0.025-2.5 mu g/mL concentration range; the attained limit of quantification is in the range 18.3-22.8 nmol/L; the within-day precision for the migration time is 0.8-1.2% and for the peak area 1.5-2.4%.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Combination of large volume sample stacking and reversed pH junction in capillary electrophoresis for online preconcentration of glycoforms of recombinant human erythropoietin
    Liu, Jing
    Liu, Zhen
    Kang, Mingchao
    Liu, Sichang
    Chen, Hong-Yuan
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (03) : 422 - 429
  • [32] Large-volume sample stacking with polarity switching for the analysis of bacteria by capillary electrophoresis with laser-induced fluorescence detection
    Yu, Lijun
    Li, Sam Fong Yau
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) : 308 - 313
  • [33] Synergistic coupling of in-line single-drop microextraction and on-line large-volume sample stacking for capillary electrophoresis/mass spectrometry
    Kim, Jihye
    Choi, Kihwan
    Chung, Doo Soo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (05) : 1067 - 1073
  • [34] Ultrasensitive enantiomeric barbiturate analysis in body fluids through capillary electrophoresis with large volume sample stacking and ultrasound assisted dispersive liquid liquid microextraction
    Chen, Meng-Chin
    Hsieh, Ming-Mu
    Huang, Xin-Yu
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1730
  • [35] Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Tetracycline Residues in Milk
    Islas, Gabriela
    Rodriguez, Jose A.
    Perez-Silva, Irma
    Miranda, Jose M.
    Ibarra, Israel S.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2018, 2018
  • [36] Online large volume sample staking preconcentration and separation of enantiomeric GHRH analogs by capillary electrophoresis
    Otin, Joanie
    Tran, N. Thuy
    Benoit, Aurelie
    Buisson, Corinne
    Taverna, Myriam
    ELECTROPHORESIS, 2023, 44 (9-10) : 807 - 817
  • [37] Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples
    Li, Pingjing
    Hu, Bin
    Li, Xiaoyong
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1247 : 49 - 56
  • [38] Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Artificial Sweeteners in Water Samples
    Lorena Camargo Medrano
    Juan Francisco Flores-Aguilar
    Gabriela Islas
    José Antonio Rodríguez
    Israel Samuel Ibarra
    Food Analytical Methods, 2019, 12 : 526 - 533
  • [39] Use of large-volume sample stacking in on-line solid-phase extraction-capillary electrophoresis for improved sensitivity
    Puig, Patricia
    Tempels, F. W. Alexander
    Somsen, Govert W.
    de Jong, Gerhardaus J.
    Borrull, Francesc
    Aguilar, Carme
    Calull, Marta
    ELECTROPHORESIS, 2008, 29 (06) : 1339 - 1346
  • [40] Field-amplified sample stacking capillary zone electrophoresis applied to the analysis of opiate drugs in hair
    Manetto, G
    Tagliaro, F
    Crivellente, F
    Pascali, VL
    Marigo, M
    ELECTROPHORESIS, 2000, 21 (14) : 2891 - 2898