Increased sensitivity potentiometric detectors for FIA

被引:10
作者
Couto, CMCM [1 ]
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
机构
[1] FAC FARM,DEPT QUIM FIS,CEQUP,P-4050 OPORTO,PORTUGAL
关键词
tubular ion-selective electrodes; flow injection analysis; increased sensitivity;
D O I
10.2116/analsci.13.403
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development of potentiometric detection systems with increased sensitivity for flow injection analysis (FIA). The detection systems are based on homogeneous crystalline membranes which are sensitive to chloride, bromide and iodide anions and copper, cadmium and lead cations. Two types of potentiometric detection systems have been established: one has two tubular electrodes sensitive to the same species placed sequentially, in which one of the electrodes works alternatively as a reference electrode (sequential detector system); the other type comprises a tubular potentiometric detector with two membranes and a conventional reference electrode (double membrane detector system). In the latter, totalling the potentials of each membrane is performed externally using an electronic summing device. The behavior of the two detection systems was evaluated in a low-dispersion FIA manifold. Their characteristics were similar to those of single membrane tubular electrodes, except for the calibration slope, for which a value approximately double was obtained.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 23 条
[1]   FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC ;
PAULIS, JM .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18) :2291-2303
[2]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[3]   FLOW CELL WITH DOUBLE SLOPE FACTOR FOR POTENTIOMETRIC DETERMINATION OF FLUORIDE AT LOW CONCENTRATIONS [J].
BORZITSKY, JA ;
DVININ, A ;
PETRUKHIN, OM ;
URUSOV, YI .
ANALYST, 1993, 118 (07) :859-861
[4]   CONSTRUCTION AND EVALUATION OF TUBULAR POTENTIOMETRIC DETECTORS SENSITIVE TO CHLORIDE, BROMIDE, AND IODIDE AND BASED ON HOMOGENEOUS CRYSTALLINE MEMBRANES [J].
FERREIRA, IMPLVO ;
LIMA, JLFC ;
ROCHA, LSM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (8-9) :314-319
[5]   TUBULAR POTENTIOMETRIC DETECTOR FOR FLOW-INJECTION BASED ON HOMOGENEOUS CRYSTALLINE MEMBRANES SENSITIVE TO COPPER, CADMIUM AND LEAD [J].
FERREIRA, IMPLVO ;
LIMA, JLFC .
ANALYST, 1994, 119 (02) :209-212
[6]   PROPERTIES OF A PHOSPHATIDYLCHOLINE DERIVATIVE OF DIPHENYL HEXATRIENE (DPH-PC) IN LYMPHOCYTE MEMBRANES - A COMPARISON WITH DPH AND THE CATIONIC DERIVATIVE TMA-DPH USING STATIC AND DYNAMIC FLUORESCENCE [J].
FERRETTI, G ;
TANGORRA, A ;
ZOLESE, G ;
CURATOLA, G .
MEMBRANE BIOCHEMISTRY, 1993, 10 (01) :17-27
[8]   FORMATION AND PROPERTIES OF MIXED LEAD SULFIDE-SILVER SULFIDE MEMBRANES FOR LEAD(II) SELECTIVE ELECTRODES [J].
HEIJNE, GJM ;
VANDERLINDEN, WE ;
DENBOEF, G .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :193-205
[9]   FORMATION OF MIXED COPPER(II) SULFIDE SILVER(I) SULFIDE MEMBRANES FOR COPPER(II)-SELECTIVE ELECTRODES [J].
HEIJNE, GJM ;
VANDERLINDEN, WE ;
DENBOEF, G .
ANALYTICA CHIMICA ACTA, 1977, 89 (02) :287-296
[10]   MULTIPLE SENSOR RESPONSE IN SEGMENTED FLOW-ANALYSIS WITH ION-SELECTIVE ELECTRODES [J].
HIBBERT, DB ;
ALEXANDER, PW ;
RACHMAWATI, S ;
CARUANA, SA .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1015-1019