Determination of the enthalpy of PCM as a function of temperature using a heat-flux DSC-A study of different measurement procedures and their accuracy

被引:138
作者
Castellon, C. [1 ]
Guenther, E. [2 ]
Mehling, H. [2 ]
Hiebler, S. [2 ]
Cabeza, L. F. [1 ]
机构
[1] Univ Lleida, Ind EPS CREA, Dept Informat & Engn, GREA, Lleida 25001, Japan
[2] Bavarian Ctr Appl Energy Res ZAE Bayern, D-85748 Garching, Germany
关键词
cooling thermal storage; phase change material (PCM); heat-flux DSC; dynamic method; step method; RT27; calorimetry; material property determination; thermal energy storage;
D O I
10.1002/er.1443
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal energy storage by latent heat allows storing high amounts of energy working in narrow margins of temperature. The use of phase change material (PCM) for the latent heat storage has been studied in different applications and it has been commercialized in containers to transport blood, products sensible to temperature, to decrease their energy demand. The use of PCM in cooling and refrigeration has been attracting a lot of interest lately, but for all applications, the properties of these materials need to be known with sufficient accuracy. Regarding heat storage, it is necessary to know the enthalpy as a function of temperature. The most widely used calorimeter is the heat-flux differential scanning calorimetry (hf-DSC). The objective of this study is to investigate different methods for hf-DSC analysis, namely the dynamic method and the step method, and to test their accuracy in the determination of enthalpy-temperature relationship of PCM. For the dynamic method, a strong influence of heating/cooling rate was observed. For the step method, the resulting enthalpy-temperature relationship is independent of heating/cooling rate. Commercial PCM RT27 was chosen as sample material to avoid subcooling and kinetic effects in the test measurements. The approach introduced in this study can be used to carry out similar investigations for other classes of PCM and/or other DSC instruments. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:1258 / 1265
页数:8
相关论文
共 11 条
  • [1] Dincer I., 2002, Thermal energy storage: systems and applications
  • [2] Heat capacity measurement of organic thermal energy storage materials
    Divi, Suresh
    Chellappa, Raja
    Chandra, Dhanesh
    [J]. JOURNAL OF CHEMICAL THERMODYNAMICS, 2006, 38 (11) : 1312 - 1326
  • [3] Temperature, heat and heat flow rate calibration of differential scanning calorimeters
    Gmelin, E
    Sarge, SM
    [J]. THERMOCHIMICA ACTA, 2000, 347 (1-2) : 9 - 13
  • [4] Phase transition temperature ranges and storage density of paraffin wax phase change materials
    He, B
    Martin, V
    Setterwall, F
    [J]. ENERGY, 2004, 29 (11) : 1785 - 1804
  • [5] HE B, 2004, KTH CHEM ENG TECHNOL
  • [6] A review on energy conservation in building applications with thermal storage by latent heat using phase change materials
    Khudhair, AM
    Farid, MM
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (02) : 263 - 275
  • [7] LANE GA, 1986, SOLAR HEAT STORAGE L
  • [8] MEHLING H, 2006, 7 IIR C PHAS CHANG M
  • [9] RUDTSCH S, 2000, THERMOCHIM ACTA, V382, P17
  • [10] Speyer R.F., 1994, THERMAL ANAL MAT