Impact of Cold Temperatures on Nitrogen Removal in Denitrifying Down-Flow Hanging Sponge (DDHS) Reactors

被引:6
作者
Collings, Emily J. [1 ]
Bunce, Joshua T. [1 ]
Jong, Mui-Choo [1 ]
Graham, David W. [1 ]
机构
[1] Newcastle Univ, Sch Engn, Cassie Bldg, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
decentralised wastewater treatment; bioreactors; down-flow hanging sponge; cold temperature; total nitrogen removal; WASTE-WATER; DHS REACTOR; NITRIFICATION; GROWTH; OXYGEN;
D O I
10.3390/w12072029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Innovative and low-energy solutions for the removal of nitrogen from domestic wastewater are needed to achieve regulatory ambitions. However, there is a lack of appropriate technologies for use in non-centralised applications, where receiving waterbodies also are potentially sensitive. Denitrifying down-flow hanging sponge (DDHS) reactors are a promising solution but their performance has not been assessed under colder operating conditions pertinent to northern climates. Two DDHS reactor configurations (short and tall anoxic zones) were tested under "typical" UK winter, summer, and spring/autumn temperatures. At 22 degrees C, both reactors achieved >58% total nitrogen (TN) removal from domestic wastewater with no significant differences in removal rates between configurations. However, denitrification was lost at 13 degrees C in the reactor with the short anoxic zone, and was lost totally in both systems at 6 degrees C. Efficient nitrification was retained at 6 degrees C in both reactors (>90% removal NH4-N), suggesting that while elevated TN removal was not retained under colder conditions, the DDHS systems still effectively removed ammonia under UK winter conditions. DDHS reactors show promise for use under colder temperature conditions, although optimisation is needed, including the derivation of temperature correction factors for nitrogen removal.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Influence of hydraulic loading rate on performance and energy-efficient of a pilot-scale down-flow hanging sponge reactor treating domestic wastewater
    Tra, Van-Tung
    Dang, Bao-Trong
    Binh, Quach An
    Nguyen, Quy-Hao
    Nguyen, Phuong-Thao
    Nguyen, Hong-Hai
    Nguyen, Thanh-Tin
    Le, Thanh-Hai
    Le, Duc-Trung
    Itayama, Tomoaki
    Bui, Xuan-Thanh
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2021, 21
  • [42] Pilot-scale experiment of down-flow hanging sponge for direct treatment of low-strength municipal wastewater in Bangkok, Thailand
    Takashi Onodera
    Wilasinee Yoochatchaval
    Haruhiko Sumino
    Motoyuki Mizuochi
    Tomohiro Okadera
    Tsuyoshi Fujita
    Pathan Banjongproo
    Kazuaki Syutsubo
    Bioprocess and Biosystems Engineering, 2014, 37 : 2281 - 2287
  • [43] Development of a new non-aeration-based sewage treatment technology: Performance evaluation of a full-scale down-flow hanging sponge reactor employing third-generation sponge carriers
    Okubo, Tsutomu
    Kubota, Kengo
    Yamaguchi, Takashi
    Uemura, Shigeki
    Harada, Hideki
    WATER RESEARCH, 2016, 102 : 138 - 146
  • [44] Performance of down-flow hanging sponge (DHS) reactor coupled with up-flow anaerobic sludge blanket (UASB) reactor for treatment of onion dehydration wastewater
    El-Kamah, Hala
    Mahmoud, Mohamed
    Tawfik, Ahmed
    BIORESOURCE TECHNOLOGY, 2011, 102 (14) : 7029 - 7035
  • [45] Eukaryotic Community Shift in Response to Organic Loading Rate of an Aerobic Trickling Filter (Down-Flow Hanging Sponge Reactor) Treating Domestic Sewage
    Miyaoka, Yuma
    Hatamoto, Masashi
    Yamaguchi, Takashi
    Syutsubo, Kazuaki
    MICROBIAL ECOLOGY, 2017, 73 (04) : 801 - 814
  • [46] Direct treatment of high-strength soft drink wastewater using a down-flow hanging sponge reactor: performance and microbial community dynamics
    Liao, Junhui
    Fang, Curtis
    Yu, Jimmy
    Sathyagal, Arun
    Willman, Eric
    Liu, Wen-Tso
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2017, 101 (14) : 5925 - 5936
  • [47] Eukaryotic Community Shift in Response to Organic Loading Rate of an Aerobic Trickling Filter (Down-Flow Hanging Sponge Reactor) Treating Domestic Sewage
    Yuma Miyaoka
    Masashi Hatamoto
    Takashi Yamaguchi
    Kazuaki Syutsubo
    Microbial Ecology, 2017, 73 : 801 - 814
  • [48] Evaluation of the resilience of a full-scale down-flow hanging sponge reactor to long-term outages at a sewage treatment plant in India
    Onodera, Takashi
    Takayama, Daisuke
    Ohashi, Akiyoshi
    Yamaguchi, Takashi
    Uemura, Shigeki
    Harada, Hideki
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2016, 181 : 832 - 837
  • [49] Application of Biofloc-Down flow hanging sponge system to remove nitrogen components in recirculating zero water exchange aquaculture system
    Wandana, Samadhi
    Adlin, Nur
    Satanwat, Penpicha
    Pungrasmi, Wiboonluk
    Kotcharoen, Wilasinee
    Takeuchi, Yutaka
    Watari, Takahiro
    Hatamoto, Masashi
    Yamaguchi, Takashi
    BIORESOURCE TECHNOLOGY, 2024, 413
  • [50] Effluent treatment in an aquaponics-based closed aquaculture system with single-stage nitrification denitrification using a down-flow hanging sponge reactor
    Tanikawa, Daisuke
    Nakamura, Yuka
    Tokuzawa, Hiromi
    Hirakata, Yuga
    Hatamoto, Masashi
    Yamaguchi, Takashi
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2018, 132 : 268 - 273