Determination of Water Uptake of Polymeric Ion-Selective Membranes with the Coulometric Karl Fischer and FT-IR-Attenuated Total Reflection Techniques

被引:46
作者
He, Ning [1 ]
Lindfors, Tom [1 ,2 ]
机构
[1] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, FIN-20500 Turku, Finland
[2] Acad Finland, Helsinki, Finland
基金
芬兰科学院;
关键词
PLASTICIZED POLY(VINYL CHLORIDE); NEUTRAL-CARRIER; SILICONE-RUBBER; ELECTRODES; TRANSPORT; DIFFUSION; ATR;
D O I
10.1021/ac3027838
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The water uptake of plasticized poly(vinyl chloride) (PVC) and silicone rubber (SR) based calcium-selective membranes which are commonly used in solid-contact and coated-wire ion-selective electrodes (SC-ISEs and CWEs) was quantified with the oven based coulometric Karl Fischer (KF) technique. Two different membrane types were studied: (1) the plasticized PVC or SR (RTV 3140) membrane matrix without other added membrane components and (2) the full Ca2+-selective membrane formulation consisting of the membrane matrixes, potassium tetrakis[3,5-bis(trifluoromethyl)-phenyl]borate and calcium ionophore IV (ETH 5234) or calcium ionophore I (ETH 1001). The membranes were contacted for 24 h either asymmetrically from one side or symmetrically from both sides with deionized water (DIW) or 0.1 M solutions of CaCl2, KCl, or NaCl. It was found that the water uptake was higher for symmetrically contacted membranes. The highest water uptake (0.15-0.17 wt %) was obtained for the plasticized PVC based Ca2+-selective membranes in DIW, whereas the water uptake was lower in 0.1 M electrolyte solutions. Symmetrically contacted Ca2+-selective SR membranes had much lower water uptake in 0.1 M CaCl2 (0.03 wt %) than their plasticized PVC counterparts (0.1 wt %). However, the (noncontacted) SR membranes contained initially much more water (0.09-0.15 wt %) than the PVC membranes (0.04-0.07 wt %). Furthermore, in good accordance with the KF measurements, it was verified with FT-IR-attenuated total reflection (ATR) spectroscopy that the water content at the substrate/membrane interface and consequently in the whole membrane was influenced by the electrolyte solution.
引用
收藏
页码:1006 / 1012
页数:7
相关论文
共 30 条
[1]   Water Transport in Poly(n-butyl acrylate) Ion-Selective Membranes [J].
Appiah-Kusi, Charles ;
Kew, Simon J. ;
Hall, Elizabeth .
ELECTROANALYSIS, 2009, 21 (17-18) :1992-2003
[2]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[3]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[4]   Evidence of a water layer in solid-contact polymeric ion sensors [J].
De Marco, Roland ;
Veder, Jean-Pierre ;
Clarke, Graeme ;
Nelson, Andrew ;
Prince, Kathryn ;
Pretsch, Erno ;
Bakker, Eric .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2008, 10 (01) :73-76
[5]   LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS [J].
DINTEN, O ;
SPICHIGER, UE ;
CHANIOTAKIS, N ;
GEHRIG, P ;
RUSTERHOLZ, B ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :596-603
[6]  
dos Santos DJVA, 2002, CHEMPHYSCHEM, V3, P946, DOI 10.1002/1439-7641(20021115)3:11<946::AID-CPHC946>3.0.CO
[7]  
2-M
[8]   Influence of the solution cation mobility on the water uptake estimation of PVC Plastisol freestanding films by EIS [J].
Duarte, R. G. ;
Castela, A. S. ;
Ferreira, M. G. S. .
PROGRESS IN ORGANIC COATINGS, 2006, 57 (04) :408-415
[9]  
Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO
[10]  
2-Q