Correlation Between Central Corneal Thickness, Anterior Chamber Depth, and Corneal Keratometry as Measured by Oculyzer II and WaveLight OB820 in Preoperative Cataract Surgery Patients

被引:19
作者
Kanellopoulos, A. John [1 ,2 ]
Asimellis, George [1 ]
机构
[1] Laservis Eye Inst, Athens, Greece
[2] NYU, Sch Med, New York, NY USA
关键词
LOW-COHERENCE REFLECTOMETRY; BIOMETRY; PENTACAM; PACHYMETRY; FORMULA; INTERFEROMETRY; REPEATABILITY; TOMOGRAPHY; ULTRASOUND; AGREEMENT;
D O I
10.3928/1081597X-20121005-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare and correlate central corneal thickness (CCT), anterior chamber depth (ACD), and keratometric (flat and steep K) measurements using two anterior segment imaging methods, a Scheimpflug camera system (Oculyzer II [Oculus Optikger te GmbH]) and a partial coherence biometry system (WaveLight OB820 [Alcon Laboratories Inc]) in eyes undergoing cataract surgery. METHODS: Ninety patients (mean age: 66 +/- 13 years [range: 32 to 88 years]) underwent preoperative measurement of CCT, ACD, and keratometric measurements by Scheimpflug tomography (Oculyzer II) and optical low coherence refl ectometry (WaveLight OB820). Interdevice agreement and correlation between the two techniques were assessed. RESULTS: All measurements were highly correlated and showed no clinically significant difference between methods. Mean CCT was 554.21 +/- 39.07 mu m and 546.59 +/- 37.75 mu m for the Oculyzer II and WaveLight OB820, respectively (R-2 = 0.9268). Mean ACD was 2.63 +/- 0.44 mm and 2.63 +/- 0.43 mm for the Oculyzer II and WaveLight OB820, respectively (R-2 = 0.9488). The principal meridian keratometric values were also highly correlated. Mean flat K was 42.88 +/- 1.50 diopters (D) and 42.96 +/- 1.40 D for the Oculyzer II and WaveLight OB820, respectively (R-2 = 0.8741). Mean steep K was 44.08 +/- 1.79 D and 44.26 +/- 1.95 D for the Oculyzer II and WaveLight OB820, respectively (R-2 = 0.9159). CONCLUSIONS: Our data show that the Oculyzer II and WaveLight OB820 provide measurements that are in agreement with published values for CCT and ACD in patients. Excellent agreement for CCT and ACD was found between the two devices, as demonstrated by a high degree of correlation and linearity, in addition to minimal bias. Thus, CCT, ACD, and K measurements by these instruments can both be used in clinical preparation, and their agreement is an ensuring precision factor for cataract and refractive surgeons. [J Refract Surg. 2012;28(12):895-900.] doi: 10.3928/1081597X-20121005-07
引用
收藏
页码:895 / 900
页数:6
相关论文
共 26 条
  • [11] Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    Huang, Jinhai
    Pesudovs, Konrad
    Wen, Daizong
    Chen, Shihao
    Wright, Thomas
    Wang, Xiaoyu
    Li, Yini
    Wang, Qinmei
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 341 - 348
  • [12] Agreement analysis of LENSTAR with other techniques of biometry
    Jasvinder, S.
    Khang, T. F.
    Sarinder, K. K. S.
    Loo, V. P.
    Subrayan, V.
    [J]. EYE, 2011, 25 (06) : 717 - 724
  • [13] Spectral-Domain Optical Coherence Tomography: A Comparison of Modern High-Resolution Retinal Imaging Systems
    Kiernan, Daniel F.
    Mieler, William F.
    Hariprasad, Seenu M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (01) : 18 - 31
  • [14] Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both Devices
    Koktekir, Bengu E.
    Gedik, Sansal
    Bakbak, Berker
    [J]. CORNEA, 2012, 31 (11) : 1278 - 1281
  • [15] Kolodziejczyk Wojciech, 2011, Klin Oczna, V113, P47
  • [16] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17
  • [17] Comparison of central corneal thickness using optical low-coherence reflectometry and spectral-domain optical coherence tomography
    Lopez-Miguel, Alberto
    Encarnacion Correa-Perez, Maria
    Miranda-Anta, Silvia
    Iglesias-Cortinas, Dario
    Begona Coco-Martin, Maria
    Maldonado, Miguel J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (05) : 758 - 764
  • [18] Performance of three biometry devices in patients with different grades of age-related cataract
    Mylonas, Georgios
    Sacu, Stefan
    Buehl, Wolf
    Ritter, Markus
    Georgopoulos, Michael
    Schmidt-Erfurth, Ursula
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (03) : e237 - e241
  • [19] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    [J]. CORNEA, 2012, 31 (09) : 983 - 988
  • [20] Prediction of the effective postoperative (intraocular lens) anterior chamber depth
    Olsen, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03) : 419 - 424