Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [41] Determination of residues of UV filters in natural waters by solid-phase extraction coupled to liquid chromatography-photodiode array detection and gas chromatography-mass spectrometry
    Giokas, DL
    Sakkas, VA
    Albanis, TA
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1026 (1-2) : 289 - 293
  • [42] Determination of chloramphenicol and three tetracyclines by solid phase extraction and high performance liquid chromatography-ultraviolet detection
    Liu Hong
    Zhang Guo-Ping
    Liu Cong-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 315 - 319
  • [44] Simultaneous determination of 22 antibiotics in environmental water samples by solid phase extraction. high performance liquid chromatography.tandem mass spectrometry
    Wang Jin
    Ye Kaixiao
    Tian Yan
    Liu Ke
    Liang Liuling
    Li Qingqian
    Huang Ning
    Wang Xinting
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (03) : 241 - 249
  • [45] Simultaneous determination of phenyl- and sulfonylurea herbicides in water by solid-phase extraction and liquid chromatography with UV diode array or mass spectrometric detection
    Carabias-Martínez, R
    Rodríguez-Gonzalo, E
    Herrero-Hernández, E
    Hernández-Méndez, J
    ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) : 71 - 79
  • [46] Determination of ciprofloxacin in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with fluorescence detection
    Lian, Ziru
    Wang, Jiangtao
    MARINE POLLUTION BULLETIN, 2016, 111 (1-2) : 411 - 417
  • [47] Low-temperature partitioning extraction followed by liquid chromatography tandem mass spectrometry determination of multiclass antibiotics in solid and soluble wastewater fractions
    Rodrigues Ferreira da Cunha, Camila Cristina
    Freitas, Mylena Gomes
    da Silva Rodrigues, Daniel Aparecido
    Correa de Barros, Andre Luis
    Ribeiro, Marcelo Carlos
    Sanson, Ananda Lima
    de Cassia Franco Afonso, Robson Jose
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1650
  • [48] Simultaneous determination of eight antibiotics from distinct classes in surface and wastewater samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionisation mass spectrometry
    Jank, Louise
    Hoff, Rodrigo Barcellos
    da Costa, Flavia Justina
    Pizzolato, Tania Mara
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (10) : 1013 - 1037
  • [49] Determination of Antibiotics in Brazilian Surface Waters Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Locatelli, Marco Antonio F.
    Sodre, Fernando F.
    Jardim, Wilson F.
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2011, 60 (03) : 385 - 393
  • [50] Detection of 15 antibiotics in water by solid phase extraction-ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry
    Gao, Zhengang
    Liang, Yanpeng
    Zeng, Honghu
    Qin, Litang
    Chinese Journal of Analysis Laboratory, 2021, 40 (08) : 875 - 880