Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [31] Simultaneous determination of three classes of antibiotics in the suspended solids of swine wastewater by ultrasonic extraction, solid-phase extraction and liquid chromatography-mass spectrometry
    Pan, Xun
    Qiang, Zhimin
    Ben, Weiwei
    Chen, Meixue
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2011, 23 (10) : 1729 - 1737
  • [32] Optimization of antibiotic analysis in water by solid-phase extraction and high performance liquid chromatography-mass spectrometry/mass spectrometry
    Zhou, John L.
    Maskaoui, Khalid
    Lufadeju, Adeleye
    ANALYTICA CHIMICA ACTA, 2012, 731 : 32 - 39
  • [33] Simultaneous determination of 23 antibiotics in mariculture water using solid-phase extraction and high performance liquid chromatography-tandem mass spectrometry
    Du Juan
    Zhao Hongxia
    Chen Jingwen
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (04) : 348 - 353
  • [34] Simultaneous Determination of Tylosin Tartrate and Tylvalosin Tartrate in Wastewater by the Solid-Phase Extraction and High-Performance Liquid Chromatography-Diode Array Detector Method
    Chai, Ruina
    Cheng, Jianguo
    Zhang, Shuheng
    Ma, Litong
    Duan, Jianguo
    Zhao, Wenyuan
    Wang, Xiaoxia
    Fang, Chen
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [35] Detection and quantification of multiclass antibiotic residues in poultry products using solid-phase extraction and high-performance liquid chromatography with diode array detection
    Oyedeji, Abdulrasaq O.
    Msagati, Titus A. M.
    Williams, Akan B.
    Benson, Nsikak U.
    HELIYON, 2021, 7 (12)
  • [36] Identification of impurities in lovastatin by high performance liquid chromatography-diode array detection-mass spectrometry
    Wu, YJ
    Zhu, W
    Shao, Q
    Cheng, YY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (01) : 115 - 118
  • [37] Selective and rapid determination of tadalafil and finasteride using solid phase extraction by high performance liquid chromatography and tandem mass spectrometry
    Nagaraju, Pappula
    Kodali, Balaji
    Datla, Peda Varma
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 152 : 215 - 223
  • [38] Validation of antibiotics in catfish by on-line solid phase extraction coupled to liquid chromatography tandem mass spectrometry
    Hurtado de Mendoza, Jorge
    Maggi, Luana
    Bonetto, Liliana
    Rodriguez Carmena, Beatriz
    Lezana, Alicia
    Mocholi, Francisco A.
    Carmona, Manuel
    FOOD CHEMISTRY, 2012, 134 (02) : 1149 - 1155
  • [39] Determination of phenols by solid phase extraction and high performance liquid chromatography
    Hu, QF
    Yang, GY
    Huang, ZJ
    Yin, JY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (05) : 560 - 563
  • [40] Simultaneous determination of five types of 40 antibiotics in surface water using high performance liquid chromatography-tandem mass spectrometry
    Feng Mengjuan
    Yang Zhengbiao
    Zhang Qin
    Song Ninghui
    Liu Yanhua
    Guo Ruixin
    Chen Jianqiu
    Zhang Shenghu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (05) : 525 - 532