Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [1] Determination of Antibiotics in Surface Water by Solid-Phase Extraction and High-Performance Liquid Chromatography with Diode Array and Mass Spectrometry Detection
    Soran, Maria-Loredana
    Lung, Ildiko
    Opris, Ocsana
    Floare-Avram, Veronica
    Coman, Cristian
    ANALYTICAL LETTERS, 2017, 50 (07) : 1209 - 1218
  • [2] Determination of Pharmaceuticals in Coastal Systems Using Solid Phase Extraction (SPE) Followed by Ultra Performance Liquid Chromatography - tandem Mass Spectrometry (UPLC-MS/MS)
    Maria Baena-Nogueras, Rosa
    Pintado-Herrera, Marina G.
    Gonzalez-Mazo, Eduardo
    Lara-Martin, Pablo A.
    CURRENT ANALYTICAL CHEMISTRY, 2016, 12 (03) : 183 - 201
  • [3] Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry
    Na Guangshui
    Gu Jia
    Ge Linke
    Zhang Peng
    Wang Zhen
    Liu Chunyang
    Zhang Lin
    CHINESE JOURNAL OF OCEANOLOGY AND LIMNOLOGY, 2011, 29 (05) : 1093 - 1102
  • [4] Determination of carbamate pesticides in water by high performance, liquid chromatography/mass spectrometry with solid phase extraction
    Chen, JG
    Zhao, QL
    Lian, ZY
    Wang, YN
    Fan, XJ
    Tan, AJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (08) : 1167 - 1170
  • [5] Solid Phase Extraction and High-Performance Thin-Layer Chromatography Quantification of Some Antibiotics from Surface Waters
    Opris, Ocsana
    Coman, Virginia
    Copaciu, Florina
    Vlassa, Mihaela
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2012, 25 (06) : 516 - 522
  • [6] Simultaneous Detection of Sulfamethoxazole, Diclofenac, Carbamazepine, and Bezafibrate by Solid Phase Extraction and High Performance Liquid Chromatography with Diode Array Detection
    Zhou, Z.
    Jiang, J. -Q.
    JOURNAL OF APPLIED SPECTROSCOPY, 2014, 81 (02) : 273 - 278
  • [7] Multianalyte method for the determination of pharmaceuticals in wastewater samples using solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Dasenaki, Marilena E.
    Thomaidis, Nikolaos S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (15) : 4229 - 4245
  • [8] Solid-phase extraction followed by liquid chromatography-mass spectrometry for trace determination of β-lactam antibiotics in bovine milk
    Bruno, F
    Curini, R
    Di Corcia, A
    Nazzari, M
    Samperi, R
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (07) : 3463 - 3470
  • [9] Determination of pharmaceuticals in wastewaters using solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Gilart, Nuria
    Maria Marce, Rosa
    Borrull, Francesc
    Fontanals, Nuria
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (07) : 875 - 882
  • [10] Determination of antibiotics in aquatic environment by solid-phase extraction followed by liquid chromatography-electrospray ionization mass spectrometry
    Rao, R. Nageswara
    Venkateswarlu, N.
    Narsimha, R.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1187 (1-2) : 151 - 164