Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Specific and Rapid Detection of Tilapia Lake Virus

被引:4
|
作者
Phusantisampan, Theerawut [1 ]
Rawiwan, Pattarasuda [2 ,3 ]
Roy, Sri Rajiv Kumar [2 ]
Sriariyanun, Malinee [4 ]
Surachetpong, Win [2 ,3 ]
机构
[1] King Mongkuts Univ Technol North Bangkok KMUTNB, Fac Appl Sci, Dept Biotechnol, Bangkok, Thailand
[2] Kasetsart Univ, Fac Vet Med, Dept Vet Microbiol & Immunol, Bangkok, Thailand
[3] Kasetsart Univ, Inst Adv Studies, Ctr Adv Studies Agr & Food, Bangkok, Thailand
[4] King Mongkuts Univ Technol North Bangkok KMUTNB, Sirindhorn Thai German Int Grad Sch Engn TGGS, Dept Chem & Proc Engn, Bangkok, Thailand
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2020年 / 159期
关键词
Immunology and Infection; Issue; 159; tilapia lake virus; diagnosis; tilapia; RT-LAMP; RT-qPCR; screening tool; CATFISH ICTALURUS-PUNCTATUS; CLINICAL-SAMPLES; FISH; IDENTIFICATION; THAILAND; QPCR; PCR;
D O I
10.3791/61025
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Tilapia lake virus disease (TiLVD), an emerging viral disease in tilapia caused by the tilapia lake virus (TiLV), is a persistent challenge in the aquaculture industry that has resulted in the mass morbidity and mortality of tilapia in many parts of the world. An effective, rapid, and accurate diagnostic assay for TiLV infection is therefore necessary to detect the initial infection and to prevent the spread of the disease in aquaculture farming. In this study, a highly sensitive and practical reverse transcription loop-mediated isothermal amplification (RT-LAMP) method is presented to detect tilapia lake virus in fish tissue. A comparison of the RT-qPCR and RT-LAMP assays of infected samples revealed positive results in 63 (100%) and 51 (80.95%) samples, respectively. Moreover, an analysis of uninfected samples showed that all 63 uninfected tissues yielded negative results for both the RT-qPCR and RT-LAMP assays. The cross-reactivity with five pathogens in tilapia was evaluated using RT-LAMP, and all the tests showed negative results. Both the liver and mucus samples obtained from infected fish showed comparable results using the RT-LAMP method, suggesting that mucus can be used in RT-LAMP as a nonlethal assay to avoid killing fish. In conclusion, the results demonstrated that the presented RT-LAMP assay provides an effective method for TiLV detection in tilapia tissue within 1 h. The method is therefore recommended as a screening tool on farms for the rapid diagnosis of TiLV.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Rapid detection of tilapia lake virus using a one-step reverse transcription loop-mediated isothermal amplification assay
    Phusantisampan, Theerawut
    Tattiyapong, Puntanat
    Mutrakulcharoen, Palita
    Sriariyanun, Malinee
    Surachetpong, Win
    AQUACULTURE, 2019, 507 : 35 - 39
  • [2] Development of a simple and rapid reverse transcription-loopmediated isothermal amplification (RT-LAMP) assay for sensitive detection of tilapia lake virus
    Yin, Jiyuan
    Wang, Qing
    Wang, Yingying
    Li, Yingying
    Zeng, Weiwei
    Wu, Jiexing
    Ren, Yan
    Tang, Yafang
    Gao, Caixia
    Hu, Huzi
    Bergmann, Sven M.
    JOURNAL OF FISH DISEASES, 2019, 42 (06) : 817 - 824
  • [3] A Bioengineered Positive Control for Rapid Detection of the Ebola Virus by Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP)
    Lam, Patricia
    Keri, Ruth A.
    Steinmetz, Nicole F.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2017, 3 (03): : 452 - 459
  • [4] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of viral hemorrhagic septicaemia virus (VHS)
    Soliman, H.
    El-Matbouli, M.
    VETERINARY MICROBIOLOGY, 2006, 114 (3-4) : 205 - 213
  • [5] Improved Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for the Rapid and Sensitive Detection of Yam mosaic virus
    Festus, Ruth O.
    Seal, Susan E.
    Prempeh, Ruth
    Quain, Marian D.
    Silva, Goncalo
    VIRUSES-BASEL, 2023, 15 (07):
  • [6] A Rapid and Sensitive Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Detection of Indian Citrus Ringspot Virus
    Kokane, Amol D.
    Kokane, Sunil B.
    Warghane, Ashish J.
    Gubyad, Mrugendra G.
    Sharma, Ashwani Kumar
    Reddy, M. Krishna
    Ghosh, Dilip Kumar
    PLANT DISEASE, 2021, 105 (05) : 1346 - 1355
  • [7] Detection of enterovirus 71 using reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Wang, Xiang
    Zhu, Jun-ping
    Zhang, Qian
    Xu, Zi-gang
    Zhang, Fang
    Zhao, Zhi-hui
    Zheng, Wen-zhi
    Zheng, Li-shu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 330 - 334
  • [8] Rapid Detection of Foot-and-Mouth Disease Virus by Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP)
    Shao, Jun-Jun
    Chang, Hui-Yun
    Zhou, Guang-Qing
    Cong, Guo-Zheng
    Du, Jun-Zheng
    Lin, Tong
    Gao, Shan-Dian
    He, Ji-Jun
    Liu, Xiang-Tao
    Liu, Ji-Xing
    Gao, Jin-Liang
    INTERNATIONAL JOURNAL OF APPLIED RESEARCH IN VETERINARY MEDICINE, 2010, 8 (02): : 133 - 142
  • [9] Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for Rapid Diagnosis of Sugarcane yellow leaf virus in Sugarcane
    L. Anandakumar
    K. Bagyalakshmi
    K. Nithya
    B. Parameswari
    R. Viswanathan
    Sugar Tech, 2018, 20 : 708 - 716
  • [10] Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for Rapid Diagnosis of Sugarcane yellow leaf virus in Sugarcane
    Anandakumar, L.
    Bagyalakshmi, K.
    Nithya, K.
    Parameswari, B.
    Viswanathan, R.
    SUGAR TECH, 2018, 20 (06) : 708 - 716