Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population

被引:11
|
作者
Kim, Young-June [1 ]
Rhee, Woo Tack [1 ]
Lee, Sang-Bok [1 ]
You, Seung-Hoon [1 ]
Lee, Sang-Youl [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Neurosurg, Sacheon Myeon 210711, Gangneung, South Korea
关键词
axis; laminar screw;
D O I
10.3340/jkns.2008.44.1.15
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (+/- 1.0) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was 43.2 degrees and mean slope angle was 32.9 degrees. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 38 条
  • [31] Comparison of C2-3 Pedicle Screw Fixation With C2 Spinous Muscle Complex and Iliac Bone Graft for Instable Hangman Fracture
    Xu, Dingli
    Gan, Kaifeng
    Wang, Yang
    Wang, Yulong
    Ma, Weihu
    FRONTIERS IN SURGERY, 2021, 8
  • [32] Combined Anterior C2-C3 Fusion and C2 Pedicle Screw Fixation for the Treatment of Unstable Hangman's Fracture A Contrast to Anterior Approach Only
    Xie, Ning
    Khoo, Larry T.
    Yuan, Wen
    Ye, Xiao-Jian
    Chen, De-Yu
    Xiao, Jian-Ru
    Ni, Bin
    SPINE, 2010, 35 (06) : 613 - 619
  • [33] Clinical Outcome Analysis of Posterior C1 and C2 Screw Rod Fixation (Harms-Goel Technique) in Traumatic Atlantoaxial Dislocation
    Singh, Deepak Kumar
    Agrahari, Vrihaspati Kumar
    Kaif, Md
    Yadav, Kuldeep
    Singh, Rakesh Kumar
    Ahmad, Farhan
    Khan, Khursheed
    Pathak, Vipul
    INDIAN JOURNAL OF NEUROTRAUMA, 2019, 16 (01) : 58 - 62
  • [34] Posterior occipito-axial fixation applied C2 laminar screws for pediatric atlantoaxial instability caused by Down syndrome: Report of 2 cases
    Kuroki, Hiroshi
    Kubo, Shinichiro
    Hamanaka, Hideaki
    Chosa, Etsuo
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2012, 6 : 210 - 215
  • [35] One-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion for the treatment of unstable hangman's fracture
    Liu, Jingchen
    Li, Ye
    Wu, Yuntao
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (03) : 667 - 672
  • [36] New entry point for C2 screw, in posterior C1-C2 fixation (Goel-Harm's technique) significantly reducing the possibility of vertebral artery injury
    Patkar, Sushil Vasant
    NEUROLOGICAL RESEARCH, 2016, 38 (02) : 93 - 97
  • [37] Unilateral C-1 posterior arch screws and C-2 laminar screws combined with a 1-side C1-2 pedicle screw system as salvage fixation for atlantoaxial instability
    Jin Guo-Xin
    Wang Huan
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (02) : 315 - 320
  • [38] Evaluation of Correction of Radiologic Parameters (Angulation and Displacement) and Accuracy of C2 Pedicle Screw Placement in Unstable Hangman's Fracture with Intraoperative Computed Tomography-Based Navigation
    Singh, Pankaj Kumar
    Verma, Satish K.
    Garg, Mayank
    Sawarkar, Dattaraj P.
    Kumar, Amandeep
    Agrawal, Deepak
    Chandra, Sarat P.
    Kale, Shashank S.
    Sharma, Bhawani S.
    Mahapatra, Ashok K.
    WORLD NEUROSURGERY, 2017, 107 : 795 - 802