Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population

被引:11
|
作者
Kim, Young-June [1 ]
Rhee, Woo Tack [1 ]
Lee, Sang-Bok [1 ]
You, Seung-Hoon [1 ]
Lee, Sang-Youl [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Neurosurg, Sacheon Myeon 210711, Gangneung, South Korea
关键词
axis; laminar screw;
D O I
10.3340/jkns.2008.44.1.15
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (+/- 1.0) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was 43.2 degrees and mean slope angle was 32.9 degrees. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 38 条
  • [21] C-2 anterior plate-screw fixation: a quantitative anatomical and morphometric evaluation
    Senoglu, M.
    Ozbag, D.
    Gumusalan, Y.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2010, 111 (10): : 566 - 569
  • [22] Morphometric Characteristics of C1-C2 Vertebrae to Perform Anterior Transarticular Crossing Screw Fixation
    Tun, Kagan
    Cemil, Berker
    Gokce, Emre Cemal
    TURKISH NEUROSURGERY, 2018, 28 (02) : 270 - 274
  • [23] Seven Years of Experience With C2 Translaminar Screw Fixation: Clinical Series and Review of the Literature
    Dorward, Ian G.
    Wright, Neill M.
    NEUROSURGERY, 2011, 68 (06) : 1491 - 1499
  • [24] Feasibility of 3.5 mm C2 pedicle screws in children: Part II a computerized tomography analysis
    Chen, Jiarui
    Cen, Jiemei
    Ma, Teng
    Du, Yuwang
    Liang, Tuo
    Liao, Shian
    Yu, Chaojie
    Sun, Xuhua
    Li, Jiakun
    Jiang, Jie
    Chen, Tianyou
    Li, Hao
    Chen, Wuhua
    Ye, Zhen
    Yao, Yuanlin
    Guo, Hao
    Zhan, Xinli
    Liu, Chong
    CLINICAL ANATOMY, 2022, 35 (03) : 347 - 353
  • [25] Characteristics and Comparisons of Morphometric Measurements and Computed Tomography Hounsfield Unit Values of C2 Laminae for Translaminar Screw Placement Between Patients With and Without Basilar Invagination
    Zhou, Lu-Ping
    Shang, Jin
    Zhang, Zhi-Gang
    Jiang, Zhen-Fei
    Zhang, Hua-Qing
    Jia, Chong-Yu
    Zhang, Ren-Jie
    Shen, Cai-Liang
    NEUROSPINE, 2022, 19 (04) : 899 - +
  • [26] TRANSLAMINAR VERSUS PEDICLE SCREW FIXATION OF C2: COMPARISON OF SURGICAL MORBIDITY AND ACCURACY OF 313 CONSECUTIVE SCREWS
    Parker, Scott L.
    McGirt, Matthew J.
    Garces-Ambrossi, Giannina L.
    Mehta, Vivek A.
    Sciubba, Daniel M.
    Witham, Timothy E.
    Gokaslan, Ziya L.
    Wolinksy, Jean-Paul
    NEUROSURGERY, 2009, 64 (05) : 343 - 348
  • [27] Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study
    Milan K. Sen
    Thomas Steffen
    Lorne Beckman
    Anthony Tsantrizos
    Rudolph Reindl
    Max Aebi
    European Spine Journal, 2005, 14 : 512 - 518
  • [28] Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1-C2 pedicle screw-rod fixation for atlantoaxial instability
    Shen, Kai
    Deng, Zhongliang
    Yang, Junsong
    Liu, Chao
    Zhang, Ranxi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (10) : 1349 - 1355
  • [29] Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients?
    Wang, Shenglin
    Wang, Chao
    Passias, Peter G.
    Yan, Ming
    Zhou, Haitao
    EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1306 - 1311
  • [30] Feasibility of C2 Lamina Screw Placement in a New Zealand Cohort: Computed Tomography Analysis According to Ethnicity and Gender
    Storey, Richard N.
    Baker, Joseph F.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2024, 18 (05) : 471 - 476