Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population

被引:11
|
作者
Kim, Young-June [1 ]
Rhee, Woo Tack [1 ]
Lee, Sang-Bok [1 ]
You, Seung-Hoon [1 ]
Lee, Sang-Youl [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Neurosurg, Sacheon Myeon 210711, Gangneung, South Korea
关键词
axis; laminar screw;
D O I
10.3340/jkns.2008.44.1.15
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (+/- 1.0) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was 43.2 degrees and mean slope angle was 32.9 degrees. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 38 条
  • [11] The dimensions of the posterior arch of C2 for instrumented screw fixation. A radiological study in the Spanish population
    Vazquez-Garcia, B.
    Villas, C.
    Pueyo, J.
    Broncano, J.
    Donat-Vargas, C.
    Alfonso, M.
    ANALES DEL SISTEMA SANITARIO DE NAVARRA, 2020, 43 (03) : 323 - 331
  • [12] POSTERIOR INSTRUMENTATION FOR LAMINAR SCREW OF C2: A DIMENSIONAL ANATOMIC STUDY OF AXIS
    Sorrenti, Luiz
    Iamaguchi, Mauricio Masasi
    Sposeto, Rafael Barban
    de Araujo, Marcelo Poderoso
    Iutaka, Alexandre Sadao
    Pessoa de Barros Filho, Tarcisio Eloy
    da Rocha, Ivan Dias
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (04): : 219 - 223
  • [13] Morphometric Analysis of the Neural Arch of C2 Vertebra in Indian Population
    Varghese, Jija E.
    Rabi, Suganthy
    Joseph, Vivek
    Jeyaseelan, Lakshmanan
    Prithishkumar, Ivan J.
    NEUROLOGY INDIA, 2024, 72 (02) : 334 - 339
  • [14] Comparison between Bilateral C2 Pedicle Screwing and Unilateral C2 Pedicle Screwing, Combined with Contralateral C2 Laminar Screwing, for Atlantoaxial Posterior Fixation
    Miyakoshi, Naohisa
    Hongo, Michio
    Kobayashi, Takashi
    Suzuki, Tetsuya
    Abe, Eiji
    Shimada, Yoichi
    ASIAN SPINE JOURNAL, 2014, 8 (06) : 777 - 785
  • [15] A Novel C2 Screw Trajectory: Preliminary Anatomic Feasibility and Biomechanical Comparison
    Dou, NingNing
    Lehrman, Jennifer N.
    Newcomb, Anna G. U. S.
    Kelly, Brian P.
    WORLD NEUROSURGERY, 2018, 113 : E93 - E100
  • [16] Feasibility of Two-Screw Anterior Fixation for Odontoid Fractures in a Chinese Population: A Morphometric Study Based on Computed Tomography
    Ai, Yixiang
    Alemayehu, Dereje Gobena
    Mao, Genwen
    Liang, Yaping
    Cao, Ran
    Hu, Jiale
    Yang, Yimin
    Ren, Zhiwei
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (06) : 983 - 988
  • [17] Morphometric Analysis of C2 Pedicle in 247 Patients and Proposal for Trajectory and Size of Pedicle Screw
    Agrawal, Mohit
    Devarajan, Leve J.
    Dharanipathy, Sundarakrishnan
    Katiyar, Varidh
    Singh, Pankaj K.
    Garg, Ajay
    Chandra, P. Sarat
    Kale, Shashank S.
    NEUROLOGY INDIA, 2021, 69 (04) : 925 - 930
  • [18] Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2–3 fusion patients?
    Shenglin Wang
    Chao Wang
    Peter G. Passias
    Ming Yan
    Haitao Zhou
    European Spine Journal, 2010, 19 : 1306 - 1311
  • [19] Inferolateral Entry Point for C2 Pedicle Screw Fixation in High Cervical Lesions
    Lee, Kwang Ho
    Kang, Dong Ho
    Lee, Chul Hee
    Hwang, Soo Hyun
    Park, In Sung
    Jung, Jin Myung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2011, 50 (04) : 341 - 347
  • [20] Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1–C2 pedicle screw–rod fixation for atlantoaxial instability
    Kai Shen
    Zhongliang Deng
    Junsong Yang
    Chao Liu
    Ranxi Zhang
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1349 - 1355