Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population

被引:11
|
作者
Kim, Young-June [1 ]
Rhee, Woo Tack [1 ]
Lee, Sang-Bok [1 ]
You, Seung-Hoon [1 ]
Lee, Sang-Youl [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Neurosurg, Sacheon Myeon 210711, Gangneung, South Korea
关键词
axis; laminar screw;
D O I
10.3340/jkns.2008.44.1.15
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (+/- 1.0) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was 43.2 degrees and mean slope angle was 32.9 degrees. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 38 条
  • [1] Morphometric trajectory analysis for the C2 crossing laminar screw technique
    Yue, Bin
    Kwak, Dai-Soon
    Kim, Moon-Kyu
    Kwon, Seong-Oh
    Han, Seung-Ho
    EUROPEAN SPINE JOURNAL, 2010, 19 (05) : 828 - 832
  • [2] The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion
    Neo M.
    Yoshitomi H.
    Takemoto M.
    Izeki M.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (4) : 635 - 639
  • [3] Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement
    Dean, Clayton L.
    Lee, Michael J.
    Robbin, Mark
    Cassinelli, Ezequiel H.
    SPINE JOURNAL, 2009, 9 (03) : 258 - 262
  • [4] Feasibility of C2 Pedicle Screw Fixation With the "in-out-in" Technique for Patients With Basilar Invagination
    Xu, Panjie
    Lin, Junyu
    Xiao, Hang
    Zheng, Jianying
    Ji, Wei
    SPINE, 2024, 49 (11) : 798 - 804
  • [5] C2 crossing laminar screws: Cadaveric morphometric analysis
    Wang, Michael Y.
    NEUROSURGERY, 2006, 59 (01) : 84 - 87
  • [6] The Feasibility of Multiple Fixation Points in C2
    Ngoc, Quyen Nguyen
    Riew, K. Daniel
    Lee, So Min
    Park, Sang-Min
    Kim, Ho-Joong
    Chang, Bong-Soon
    Lee, Sang-Hun
    Lee, Jae Chul
    Yeom, Jin S.
    ASIAN SPINE JOURNAL, 2023, 17 (05) : 888 - 893
  • [7] Posterior C2 fixation using bilateral, crossing C2 laminar screws - Case series and technical note
    Wright, NM
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02): : 158 - 162
  • [8] TOMOGRAPHIC ANALYSIS FOR C2 SCREW PLACEMENT IN RHEUMATOID ARTHRITIS PATIENTS
    Astolfi, Rodrigo Schroll
    Tachibana, Wilson Tadao
    Letaif, Olavo Biraghi
    Cristante, Alexandre Fogaca
    Oliveira, Reginaldo Perilo
    Pessoa de Barros Filho, Tarcisio Eloy
    ACTA ORTOPEDICA BRASILEIRA, 2012, 20 (04): : 207 - 209
  • [9] C2 Intralaminar Screw Placement: A Quantitative Anatomical and Morphometric Evaluation
    Senoglu, Mehmet
    Ozbag, Davut
    Gumusalan, Yakup
    TURKISH NEUROSURGERY, 2009, 19 (03) : 245 - 248
  • [10] Modified trajectory of C2 laminar screw double bicortical purchase of the inferiorly crossing screw
    Rhee, Woo-Tack
    You, Seung-Hoon
    Jang, Yeon-Gyu
    Lee, Sang-Youl
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2008, 43 (02) : 119 - 122